Have a look at the manual Lucent Technologies Ds1/Cept1/Isdn Pri Reference Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-2 3 Table 3-1. Equipment and Software Requirements Item Systems Remarks TN464C G3V2 Universal DS1/CEPT1 b oard . It is required for all CEPT1-based trunks. It is also req uired for ISDN PRI D c hannels on G3r. It is also req uired for wid eband switc hing. The TN464D or later is req uired for ap p lic ations in Belg ium, the Netherland s, Mexic o, Arg entina, Czec hoslovakia, and Russia. TN767 G3V2, G2.2 universal mod uleDS1 b oard . Cannot b e used for ISDN PRI D c hannels on G3rV2. For this board to c ontain an ISDN PRI D c hannel on the G2.2 universal module it must b e ac c omp anied b y the TN555 p ac ket ad junc t. TN722 G3V2 DS1 trunk board . Cannot b e used for ISDN PRI sig naling on any system. TN555 G2.2 universal mod uleDS1 Pac ket Adjunc t. ISDN PRI sig naling on a D c hannel on a TN767 requires this b oard in the ad jac ent slot. ANN11C G2.2 traditional mod uleISDN PRI D c hannel is not sup p orted on this b oard . If you use the ANN11 for 24 B c hannels in an NFAS arrang ement, maintenanc e tests (e.g ., p roc ed ure 620) on these b oard s will fail. ANN35 G2.2 Trad itional Mod uleThis board supports ISDN PRI signaling only. TN765 G3iV2 Proc essor interfac e TN768 G3V2 Tone/c loc k. This b oard c an also b e used in the G2.2 universal mod ule b ut only for tones. Continued on next page
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-3 3 TN780 All G3V2 systems Tone/c loc k. Req uired for Stratum 3 c loc k. TN463 G2.2 trad itional and universal mod ulesSystem c loc k sync hronizer. One TN463 is req uired per system. It is loc ated in the TMS c arrier for multi-mod ule systems or in the mod ule c ontrol c arrier for sing le mod ule systems. TN771B/C G3V2, G2.2 universal mod uleMaintenanc e/test b oard. This b oard is req uired for ISDN PRI test c alls. On G3V2 systems, a TN771 is req uired in eac h p ort network from or to whic h ISDN test c alls will be made. On G2.2, the TN771B and later will work. On G3V2 systems, you must have the TN771C or later. SN261B G2.2 universal mod uleAnalog /d ig ital fac ility test b oard . This b oard is req uired for ISDN PRI test c alls using proc edure 648 test 2 and test 3. ESF T1 CSU All systems A CSU is req uired b y all systems when c onnec ting via c op p er to p ub lic network fac ilities in the U.S. The mod el sold b y AT&T is the ESF T1 CSU. Numb er 8 TR631 Dig ital Line UnitG3iV2, G3rV2 Used for CSU func tion at 2.048 mb ps rate. Currently availab le from AT&T Network Systems International. Cab le DS1 – board-to-CSUG2.2 universal mod ule, G3V2H600307 c able. Eig ht g roup s are availab le (G-1 throug h G-8) d iffering in leng th (25 feet to 650 feet). Extend er c ab les are also availab le b y spec ifying a leng th attrib ute (lng1 throug h lng 5). By d efault, a g roup 2 c ab le (50 feet) is shipped with the DS1 board (TN722, TN767, TN464C). Table 3-1. Equipment and Software Requirements Item Systems Remarks Continued on next page
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-4 ANN11C and ANN35 Line Compensation Jumper Settings 3 ANN11C and ANN35 Line Compensation Jumper Settings Unlike the TN722, TN767, and TN464C board s, the ANN11 and ANN35 have a switc h that must b e set for the leng th of the c ab le from the b oard to the CSU. Following are the setting s:Sync hronization cableG2.2 universal and traditional mod ulesThe g roup 334 c ab le is wired from the sync hronization sourc e DS1 b oard to the TN463 in a multimod ule system when the DS1 b oard is in a trad itional mod ule. The g roup 361 c ab le is wired from the sync hronization sourc e DS1 b oard to the TN463 in a sing le mod ule system when the DS1 board is in a traditional module. The g roup 503 c ab le is wired from the universal b us interfac e to the TN463 in a multimod ule system when the DS1 b oard is in a universal module. Cab le – ANN11/ANN35- to-CSUG2.2 trad itional mod uleGroup 380 c ab le Cab le – CSU-to-network interfac eAll ISDN PRI softwareAll All systems req uire ISDN PRI software for ISDN PRI trunks. Table 3-1. Equipment and Software Requirements Item Systems Remarks Continued on next page
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-5 TN464C Jumper Settings 3 TN464C Jumper Settings If the TN464C or later is used , two jump ers on the b oard must b e installed c orrec tly. These jump ers are on the lower left quad rant of the b oard as you look at the b oard with the front p anel in your rig ht hand . One jump er c ontrols the b it rate and the other c ontrols the imp edanc e. The 75-Ohm op tion is for use with c oaxial c ab le. The following fig ure illustrates these jump ers: Old Toggle- New Slide- Distance to Type Switches Type Switches CSU SW1 SW2 SW3 SW1 SW2 SW3 D D U C C O 0 - 133 Feet D U D C O C 133 - 266 Feet D U U C O O 266 - 399 Feet U D D O C C 399 - 533 Feet U D U O C O 533 - 655 Feet D= d own U= up C= c losed O= op en
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-6 TN464C Jumper Settings 3 Figure 3-1. Bit Rate and Impedance Jumpers on the TN464C To p BottomFaceplat e Backplane connectors 24/32 channel selector 75/120 ohm selector 24 CHNL 120 OHM 32 CHNL 75 OHMInser t the jumpers into theblockssoastojoin the center row of pins and the row designating the desired options. ckdf464 LJK 060597 TN464C/D
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-7 DS1/CEPT1 Board Cable to CSU 3 DS1/CEPT1 Board Cable to CSU A stand ard c ab le is p rovid ed with the DS1/CEPT1 b oard for c onnec ting to a CSU or other network terminating eq uip ment, suc h as a T1 multip lexer or a T1 mic rowave. This c ab le is 50 feet in leng th and c omes eq uip ped with a 25-p in c onnec tor at the G3V2 end and a 15-p in c onnec tor at the CSU end . Extend er c ab les c an also b e ord ered if the CSU is more than 50 feet from the DS1/CEPT1 board. 75 Ohm DS1/CEPT1-to CSU Cable If the TN464 (C or later) b oard is used and is op tioned for 75 Ohms, a c oaxial c ab le with a 75 Ohm c onnec tor is req uired . Presently, the d istrib utor makes this c ab le using c oaxial c ab le and a c oax-to-25 p in ad ap tor c onforming to the CCITT G703 stand ard for 75 Ohm interfac e. ESF T1 Channel Service Unit A c hannel servic e unit is req uired if the ap p lic ation req uires c onnec tion to the p ublic network with c opp er wire. AT&T p resently sells the ESF T1 CSU for these ap plic ations. The DS1 c ab le from the DS1 b oard on the switc h c onnec ts to the CSU at one end . The CSU then c onnec ts to the network interfac e, whic h is usually a smart jac k, at the other end. Thus, the CSU is an interface between the c ustomer p remises eq uip ment and the network T1 fac ility. The p rimary p urp ose of the CSU is as follows: nThe CSU ac ts as a line rep eater so that the network interfac e c an b e loc ated at varying distanc es from the nearest rep eater in the network and still maintain the correct sig nal level. nThe CSU p rovid es loop b ac k test c ap ab ilities b oth from the c ustomer sid e and from the network sid e. nThe CSU isolates the c ustomer premises eq uipment from the network, providing network equipment protection against electric al damage from the c ustomer eq uip ment. This func tion is not req uired anymore b ec ause of c hanges in the network equip ment. nThe CSU p rovid es automatic 1s d ensity req uirement to the network in the event that the c ustomer premises eq uip ment is d isc onnec ted . User op tionab le switc h setting s on the CSU p rovide these func tions.
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-8 ESF T1 Channel Service Unit 3 ESF T1 CSU Switch Settings The ESF T1 CSU should b e optioned to ag ree with the switc h administration. Thus, if the system is op tioned for ESF framing format, for examp le, so should the CSU. The ESF T1 CSU should also b e set to pass ESF and CRC-6 information transparently throug h the CSU to and from the system. ESF T1 CSU DIP Switch Settings Following are the typ ic al DIP switc h setting s for the ESF CSU when c onnec ted to a T1 fac ility. Note that these setting s are assuming ESF framing and zero c od e sup p ression (ZCS) line c od ing format in the switc h. Table 3-2. ESF T1 CSU DIP Switch Settings Switch Settings Remarks Stand- aloneMulti- line SW1-1 SW5-1 c losed This is the CSUs ad d ress. This setting will work in most ap p lic ations. When CSUs are networked with eac h other, the ad d resses might have to b e uniq ue. SW1-2 SW5-2 c losed SW1-3 SW5-3 c losed SW1-4 SW5-4 c losed SW1-5 SW5-5 c losed SW1-6 SW5-6 c losed SW1-7 SW5-7 c losed SW1-8 SW5-8 open SW2-1 SW4-1 op en This switc h sets the b it error rate threshold . These setting s are the d efault settings, whic h set the threshold at 1 error in one million b its. SW2-2 SW4-2 c losed SW2-3 SW4-3 open SW2-4 SW4-4 open SW2-5 SW4-5 op en not used SW2-6 SW4-6 op en not used SW2-7 SW4-7 op en not used Continued on next page
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-9 ESF T1 Channel Service Unit 3 SW3 SW3 This switc h is unused . All eig ht switc hes are fac tory set to op en. SW4 SW2 This switc h is unused . All eig ht switc hes are fac tory set to op en. SW5-1 SW1-8 op en This setting ind ic ates that the switc h is ESF framed . ESF framing must also b e set in the DS1 c irc uit p ac k ad ministration form. If the switc h is c losed , D4 framing is selected. SW5-2 SW1-7 c losed This setting ind ic ates that the network line c od ing format is AMI (ZCS in DEFINITY terminolog y). At p resent, the network d oes not sup p ort B8ZS end -to-end. Thus, AMI (ZCS) is usually the c orrec t op tion for c onnec tions to the p ub lic network. Note that if you are using unrestric ted fac ilities, you must use B8ZS. The op en p osition selec ts B8ZS. SW5-3 SW1-6 c losed This setting ind ic ates that the switc h is ad ministered for ZCS line c oding format (AMI in network terminolog y). Sinc e the network d oes not in g eneral sup p ort B8ZS end -to-end , ZCS should normally be ad ministered in the DS1 c irc uit p ac k ad ministration form for c onnec tions to the p ub lic network. This switc h setting must ag ree with the SW5-2 setting . For examp le, if one is AMI (ZCS) then the other must also be AMI (ZCS), and similarly for B8ZS. The op en p osition selec ts B8ZS. SW5-4 SW1-5 c losed This setting allows the CRC-6 error c orrec tion c od e from the network to b e p assed throug h unaltered to the switc h. If the switc h is optioned for ESF, this is the c orrec t setting . If the switc h is op tioned for D4, this switc h is ig nored . The op en p osition terminates the CRC-6 from the network. Table 3-2. ESF T1 CSU DIP Switch Settings Switch Settings Remarks Stand- aloneMulti- line Continued on next page
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-10 ESF T1 Channel Service Unit 3 SW5-5 SW1-4 c losed This setting allows CRC-6 c ode g enerated b y the switc h to b e p assed throug h the CSU unaltered to the T1 fac ility. Ag ain, this is the c orrec t setting if the switc h is op tioned for ESF framing . The op en p osition terminates the CRC-6 from the switc h. SW5-6 SW1-3 op en This is the d efault setting . This setting enforc es the FCC p art 68 ones d ensity req uirement. If set to the c losed p osition, the CSU enforc es the more string ent requirement of AT&T Tec hnic al Pub lic ation 62411. SW5-7 SW1-2 op en This is the d efault setting . This setting d oes not allow p olling of the far-end CSU for alarms. SW5-8 SW1-1 op en This is the d efault setting . This switc h is unused. SW6-1 SW7-1 op en This is the d efault setting . It sets all ones (AIS) keep -alive to the switc h if set to op en or the T1 fac ility if set to c losed d uring manual loop b ac k testing. SW6-2 SW7-2 op en This is the d efault setting . This setting is for d ec od ing AMI (ZCS) line c od ing from the switc h. If set to c losed , the CSU d ec od es B8ZS. The switc h should normally b e ad ministered for ZCS b ec ause B8ZS is not universally sup p orted b y the loc al exc hang e c omp anies. This op tion must b e set the same as for the switc h, for examp le, if one is set to AMI (ZCS), so must the other. SW6-3 SW7-3 op en This is the d efault setting . This setting is for d ec od ing AMI (ZCS) from the network sid e. It should b e set the same as the switc h. Thus, if the switc h is set for AMI (ZCS), then so should the network. If set to the c losed p osition, B8ZS is selec ted. Table 3-2. ESF T1 CSU DIP Switch Settings Switch Settings Remarks Stand- aloneMulti- line Continued on next page
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-11 ESF T1 Channel Service Unit 3 Switc hes SW7 on the stand-alone unit and SW8 on the multiline unit should b e set for the leng th of the c ab le from the switc h to the CSU. The setting s for the two CSUs are d ifferent, however. Following are the setting s for the standalone unit: sw 7-1 7-2 7-3 (7-4 to 7-9 not used) 0 - 133 ft O O O 134 - 266 C O O 267 - 399 O C O 400 - 533 C C O 534 - 655 O O C Following are the setting s for the multiline CSU: nFor a d istanc e from zero feet to 285 feet, switc hes SW6-1 throug h SW6-7 should all be open, and switc h SW6-8 should be closed. nFor a d istanc e from 285 feet to 500 feet, switc hes SW6-1 throug h SW6-8 should b e set as follows: — SW6-1 set to op en — SW6-2 set to op en — SW6-3 set to c losed — SW6-4 set to op en — SW6-5 set to c losed SW6-4 SW7-4 c losed This setting is for ESF framing format from the network sid e. The switc h should also b e op tioned for ESF framing . To selec t D4 framing, set to op en. SW6-5 SW7-5 c losed This is the d efault setting . It is used to d efault to the switc h c onfig uration on p owerup . SW6-6 SW7-6 open This switc h is not used SW6-7 SW7-7 open This switc h is not used. SW6-8 SW7-8 op en This is the d efault setting . It send s all ones d uring keep alive to the switc h. Closed = to the network. Table 3-2. ESF T1 CSU DIP Switch Settings Switch Settings Remarks Stand- aloneMulti- line Continued on next page