    Have a look at the manual Lucent Technologies Ds1/Cept1/Isdn Pri Reference Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-2  
    3
    Table 3-1. Equipment and Software Requirements
    Item Systems Remarks
    TN464C G3V2 Universal DS1/CEPT1 b oard . It is 
    required for all CEPT1-based trunks. It is 
    also req uired  for ISDN PRI D c hannels on 
    G3r. It is also req uired  for wid eband  
    switc hing. The TN464D or later is 
    req uired for ap p lic ations in Belg ium, the 
    Netherland s, Mexic o, Arg entina, 
    Czec hoslovakia, and Russia.
    TN767 G3V2, G2.2 
    universal mod uleDS1 b oard . Cannot b e used  for ISDN PRI 
    D c hannels on G3rV2. For this board  to 
    c ontain an ISDN PRI D c hannel on the 
    G2.2 universal module it must b e 
    ac c omp anied  b y the TN555 p ac ket 
    ad junc t.
    TN722 G3V2 DS1 trunk board . Cannot b e used  for 
    ISDN PRI sig naling  on any system.
    TN555 G2.2 universal 
    mod uleDS1 Pac ket Adjunc t. ISDN PRI sig naling 
    on a D c hannel on a TN767 requires this 
    b oard  in the ad jac ent slot.
    ANN11C G2.2 traditional 
    mod uleISDN PRI D c hannel is not sup p orted  on 
    this b oard . If you use the ANN11 for 24 B 
    c hannels in an NFAS arrang ement, 
    maintenanc e tests (e.g ., p roc ed ure 620) 
    on these b oard s will fail.
    ANN35 G2.2 Trad itional 
    Mod uleThis board supports ISDN PRI signaling 
    only.
    TN765 G3iV2 Proc essor interfac e
    TN768 G3V2 Tone/c loc k. This b oard  c an also b e used 
    in the G2.2 universal mod ule b ut only for 
    tones.
    Continued on next page 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-3  
    3
    TN780 All G3V2 systems Tone/c loc k. Req uired  for Stratum 3 c loc k.
    TN463 G2.2 trad itional 
    and  universal 
    mod ulesSystem c loc k sync hronizer. One TN463 is 
    req uired per system. It is loc ated  in the 
    TMS c arrier for multi-mod ule systems or 
    in the mod ule c ontrol c arrier for sing le 
    mod ule systems.
    TN771B/C G3V2, G2.2 
    universal mod uleMaintenanc e/test b oard. This b oard  is 
    req uired for ISDN PRI test c alls. On G3V2 
    systems, a TN771 is req uired  in eac h p ort 
    network from or to whic h ISDN test c alls 
    will be made. On G2.2, the TN771B and  
    later will work. On G3V2 systems, you 
    must have the TN771C or later.
    SN261B G2.2 universal 
    mod uleAnalog /d ig ital fac ility test b oard . This 
    b oard  is req uired  for ISDN PRI test c alls 
    using proc edure 648 test 2 and  test 3.
    ESF T1 CSU All systems A CSU is req uired  b y all systems when 
    c onnec ting via c op p er to p ub lic  network 
    fac ilities in the U.S. The mod el sold  b y 
    AT&T is the ESF T1 CSU.
    Numb er 8 
    TR631 Dig ital 
    Line UnitG3iV2, G3rV2 Used  for CSU func tion at 2.048 mb ps 
    rate. Currently availab le from AT&T 
    Network Systems International.
    Cab le DS1 – 
    board-to-CSUG2.2 universal 
    mod ule, G3V2H600307 c able. Eig ht g roup s are 
    availab le (G-1 throug h G-8) d iffering  in 
    leng th (25 feet to 650 feet). Extend er 
    c ab les are also availab le b y spec ifying  a 
    leng th attrib ute (lng1 throug h lng 5). By 
    d efault, a g roup  2 c ab le (50 feet) is 
    shipped with the DS1 board (TN722, 
    TN767, TN464C).
    Table 3-1. Equipment and Software Requirements
    Item Systems Remarks
    Continued on next page 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-4 ANN11C and ANN35 Line Compensation Jumper Settings 
    3
    ANN11C and ANN35 Line
    Compensation Jumper Settings
    Unlike the TN722, TN767, and  TN464C board s, the ANN11 and  ANN35 have a 
    switc h that must b e set for the leng th of the c ab le from the b oard  to the CSU. 
    Following  are the setting s:Sync hronization
    cableG2.2 universal 
    and  traditional 
    mod ulesThe g roup 334 c ab le is wired  from the 
    sync hronization sourc e DS1 b oard  to the 
    TN463 in a multimod ule system when the 
    DS1 b oard  is in a trad itional mod ule.
    The g roup 361 c ab le is wired  from the 
    sync hronization sourc e DS1 b oard  to the 
    TN463 in a sing le mod ule system when 
    the DS1 board is in a traditional module.
    The g roup 503 c ab le is wired  from the 
    universal b us interfac e to the TN463 in a 
    multimod ule system when the DS1 b oard  
    is in a universal module.
    Cab le – 
    ANN11/ANN35-
    to-CSUG2.2 trad itional 
    mod uleGroup  380 c ab le
    Cab le – 
    CSU-to-network
     interfac eAll
    ISDN PRI 
    softwareAll All systems req uire ISDN PRI software for 
    ISDN PRI trunks.
    Table 3-1. Equipment and Software Requirements
    Item Systems Remarks
    Continued on next page 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-5 TN464C Jumper Settings 
    3
    TN464C Jumper Settings
    If the TN464C or later is used , two jump ers on the b oard  must b e installed  
    c orrec tly. These jump ers are on the lower left quad rant of the b oard  as you look 
    at the b oard  with the front p anel in your rig ht hand . One jump er c ontrols the b it 
    rate and  the other c ontrols the imp edanc e. The 75-Ohm op tion is for use with 
    c oaxial c ab le. The following  fig ure illustrates these jump ers:
    Old Toggle-  New Slide-  Distance to
    Type Switches   Type Switches       CSU
      SW1  SW2  SW3   SW1  SW2  SW3                     
                                                       
       D    D    U     C    C    O        0 - 133 Feet  
       D    U    D     C    O    C      133 - 266 Feet 
    D    U    U     C    O    O      266 - 399 Feet  
       U    D    D     O    C    C      399 - 533 Feet  
       U  D    U     O    C    O      533 - 655 Feet  
    D= d own
    U= up
    C= c losed
    O= op en 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-6 TN464C Jumper Settings 
    3
    Figure 3-1. Bit Rate and Impedance Jumpers on the TN464C
    To p
    BottomFaceplat
    e
    Backplane
    connectors
    24/32 channel selector
    75/120 ohm selector
    24 CHNL
    120 OHM 32 CHNL
    75 OHMInser t the jumpers into
    theblockssoastojoin
    the center row of pins
    and the row designating
    the desired options.
    ckdf464 LJK 060597
    TN464C/D 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-7 DS1/CEPT1 Board Cable to CSU 
    3
    DS1/CEPT1 Board Cable to CSU
    A stand ard  c ab le is p rovid ed  with the DS1/CEPT1 b oard  for c onnec ting  to a CSU 
    or other network terminating  eq uip ment, suc h as a T1 multip lexer or a T1 
    mic rowave. This c ab le is 50 feet in leng th and c omes eq uip ped  with a 25-p in 
    c onnec tor at the G3V2 end  and  a 15-p in c onnec tor at the CSU end . Extend er 
    c ab les c an also b e ord ered  if the CSU is more than 50 feet from the DS1/CEPT1 
    board.
    75 Ohm DS1/CEPT1-to CSU Cable
    If the TN464 (C or later) b oard  is used  and  is op tioned for 75 Ohms, a c oaxial 
    c ab le with a 75 Ohm c onnec tor is req uired . Presently, the d istrib utor makes this 
    c ab le using  c oaxial c ab le and  a c oax-to-25 p in ad ap tor c onforming  to the CCITT 
    G703 stand ard  for 75 Ohm interfac e.
    ESF T1 Channel Service Unit
    A c hannel servic e unit is req uired  if the ap p lic ation req uires c onnec tion to the 
    p ublic  network with c opp er wire. AT&T p resently sells the ESF T1 CSU for these 
    ap plic ations. The DS1 c ab le from the DS1 b oard  on the switc h c onnec ts to the 
    CSU at one end . The CSU then c onnec ts to the network interfac e, whic h is 
    usually a smart jac k, at the other end. Thus, the CSU is an interface between the 
    c ustomer p remises eq uip ment and the network T1 fac ility. The p rimary p urp ose 
    of the CSU is as follows:
    nThe CSU ac ts as a line rep eater so that the network interfac e c an b e 
    loc ated  at varying distanc es from the nearest rep eater in the network and  
    still maintain the correct sig nal level.
    nThe CSU p rovid es loop b ac k test c ap ab ilities b oth from the c ustomer sid e 
    and  from the network sid e.
    nThe CSU isolates the c ustomer premises eq uipment from the network, 
    providing network equipment protection against electric al damage from 
    the c ustomer eq uip ment. This func tion is not req uired  anymore b ec ause of 
    c hanges in the network equip ment.
    nThe CSU p rovid es automatic  1s d ensity req uirement to the network in the 
    event that the c ustomer premises eq uip ment is d isc onnec ted .
    User op tionab le switc h setting s on the CSU p rovide these func tions. 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-8 ESF T1 Channel Service Unit 
    3
    ESF T1 CSU Switch Settings
    The ESF T1 CSU should  b e optioned  to ag ree with the switc h administration. 
    Thus, if the system is op tioned  for ESF framing  format, for examp le, so should  the 
    CSU. The ESF T1 CSU should  also b e set to pass ESF and  CRC-6 information 
    transparently throug h the CSU to and  from the system.
    ESF T1 CSU DIP Switch Settings
    Following  are the typ ic al DIP switc h setting s for the ESF CSU when c onnec ted  to 
    a T1 fac ility. Note that these setting s are assuming  ESF framing  and zero c od e 
    sup p ression (ZCS) line c od ing  format in the switc h. 
    Table 3-2. ESF T1 CSU DIP Switch Settings
    Switch
    Settings Remarks
    Stand-
    aloneMulti-
    line
    SW1-1 SW5-1 c losed This is the CSUs ad d ress. This setting  will work in most 
    ap p lic ations. When CSUs are networked  with eac h 
    other, the ad d resses might have to b e uniq ue.
    SW1-2 SW5-2 c losed
    SW1-3 SW5-3 c losed
    SW1-4 SW5-4 c losed
    SW1-5 SW5-5 c losed
    SW1-6 SW5-6 c losed
    SW1-7 SW5-7 c losed
    SW1-8 SW5-8 open
    SW2-1 SW4-1 op en This switc h sets the b it error rate threshold . These 
    setting s are the d efault settings, whic h set the threshold  
    at 1 error in one million b its.
    SW2-2 SW4-2 c losed
    SW2-3 SW4-3 open
    SW2-4 SW4-4 open
    SW2-5 SW4-5 op en not used
    SW2-6 SW4-6 op en not used
    SW2-7 SW4-7 op en not used
    Continued on next page 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-9 ESF T1 Channel Service Unit 
    3
    SW3 SW3 This switc h is unused . All eig ht switc hes are fac tory set 
    to op en.
    SW4 SW2 This switc h is unused . All eig ht switc hes are fac tory set 
    to op en.
    SW5-1 SW1-8 op en This setting  ind ic ates that the switc h is ESF framed . ESF 
    framing  must also b e set in the DS1 c irc uit p ac k 
    ad ministration form. If the switc h is c losed , D4 framing  is 
    selected.
    SW5-2 SW1-7 c losed This setting  ind ic ates that the network line c od ing  format 
    is AMI (ZCS in DEFINITY terminolog y). At p resent, the 
    network d oes not sup p ort B8ZS end -to-end. Thus, AMI 
    (ZCS) is usually the c orrec t op tion for c onnec tions to the 
    p ub lic  network. Note that if you are using  unrestric ted  
    fac ilities, you must use B8ZS. The op en p osition selec ts 
    B8ZS.
    SW5-3 SW1-6 c losed This setting  ind ic ates that the switc h is ad ministered  for 
    ZCS line c oding  format (AMI in network terminolog y). 
    Sinc e the network d oes not in g eneral sup p ort B8ZS 
    end -to-end , ZCS should  normally be ad ministered  in the 
    DS1 c irc uit p ac k ad ministration form for c onnec tions to 
    the p ub lic  network. This switc h setting  must ag ree with 
    the SW5-2 setting . For examp le, if one is AMI (ZCS) then 
    the other must also be AMI (ZCS), and  similarly for 
    B8ZS. The op en p osition selec ts B8ZS.
    SW5-4 SW1-5 c losed This setting  allows the CRC-6 error c orrec tion c od e from 
    the network to b e p assed throug h unaltered  to the 
    switc h. If the switc h is optioned  for ESF, this is the 
    c orrec t setting . If the switc h is op tioned for D4, this 
    switc h is ig nored . The op en p osition terminates the 
    CRC-6 from the network.
    Table 3-2. ESF T1 CSU DIP Switch Settings
    Switch
    Settings Remarks
    Stand-
    aloneMulti-
    line
    Continued on next page 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-10 ESF T1 Channel Service Unit 
    3
    SW5-5 SW1-4 c losed This setting  allows CRC-6 c ode g enerated  b y the switc h 
    to b e p assed  throug h the CSU unaltered  to the T1 
    fac ility. Ag ain, this is the c orrec t setting  if the switc h is 
    op tioned  for ESF framing . The op en p osition terminates 
    the CRC-6 from the switc h.
    SW5-6 SW1-3 op en This is the d efault setting . This setting  enforc es the FCC 
    p art 68 ones d ensity req uirement. If set to the c losed 
    p osition, the CSU enforc es the more string ent 
    requirement of AT&T Tec hnic al Pub lic ation 62411.
    SW5-7 SW1-2 op en This is the d efault setting . This setting  d oes not allow 
    p olling  of the far-end  CSU for alarms.
    SW5-8 SW1-1 op en This is the d efault setting . This switc h is unused.
    SW6-1 SW7-1 op en This is the d efault setting . It sets all ones (AIS) keep -alive 
    to the switc h if set to op en or the T1 fac ility if set to 
    c losed  d uring  manual loop b ac k testing.
    SW6-2 SW7-2 op en This is the d efault setting . This setting  is for d ec od ing  
    AMI (ZCS) line c od ing  from the switc h. If set to c losed , 
    the CSU d ec od es B8ZS. The switc h should  normally b e 
    ad ministered for ZCS b ec ause B8ZS is not universally 
    sup p orted  b y the loc al exc hang e c omp anies. This 
    op tion must b e set the same as for the switc h, for 
    examp le, if one is set to AMI (ZCS), so must the other.
    SW6-3 SW7-3 op en This is the d efault setting . This setting  is for d ec od ing  
    AMI (ZCS) from the network sid e. It should  b e set the 
    same as the switc h. Thus, if the switc h is set for AMI 
    (ZCS), then so should  the network. If set to the c losed  
    p osition, B8ZS is selec ted.
    Table 3-2. ESF T1 CSU DIP Switch Settings
    Switch
    Settings Remarks
    Stand-
    aloneMulti-
    line
    Continued on next page 
    						
    							DEFINITY Communications System Generic 2.2 and Generic 3 V2 
    DS1/CEPT1/ISDN PRI Reference  
    555-025-107  Issue 1
    July 1993
    Equipment and Software Requirements 
    Page 3-11 ESF T1 Channel Service Unit 
    3
    Switc hes SW7 on the stand-alone unit and  SW8 on the multiline unit should  b e set 
    for the leng th of the c ab le from the switc h to the CSU. The setting s for the two 
    CSUs are d ifferent, however. Following  are the setting s for the standalone unit:
    sw 7-1  7-2  7-3   (7-4 to 7-9 not used)
         0 - 133 ft     O    O    O    
       134 - 266        C    O    O    
       267 - 399        O    C    O    
       400 - 533        C    C    O    
       534 - 655        O    O    C    
    Following  are the setting s for the multiline CSU:
    nFor a d istanc e from zero feet to 285 feet, switc hes SW6-1 throug h SW6-7 
    should all be open, and switc h SW6-8 should be closed.
    nFor a d istanc e from 285 feet to 500 feet, switc hes SW6-1 throug h SW6-8 
    should  b e set as follows:
    — SW6-1 set to op en
    — SW6-2 set to op en
    — SW6-3 set to c losed
    — SW6-4 set to op en
    — SW6-5 set to c losed SW6-4 SW7-4 c losed This setting  is for ESF framing  format from the network 
    sid e. The switc h should  also b e op tioned  for ESF 
    framing . To selec t D4 framing, set to op en.
    SW6-5 SW7-5 c losed This is the d efault setting . It is used  to d efault to the 
    switc h c onfig uration on p owerup .
    SW6-6 SW7-6 open This switc h is not used
    SW6-7 SW7-7 open This switc h is not used.
    SW6-8 SW7-8 op en This is the d efault setting . It send s all ones d uring keep  
    alive to the switc h. Closed  =  to the network.
    Table 3-2. ESF T1 CSU DIP Switch Settings
    Switch
    Settings Remarks
    Stand-
    aloneMulti-
    line
    Continued on next page 
    						