Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual

Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 201

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-67 Add IP Interface Assembly 
6
5. When done, click OK, OK.
Upgrade to TN802B (R8)
NOTE:
The upgrade takes about 20 minutes.
1. Insert the flash disk into the right most slot on the TN802 IP trunk. On the 
monitor, a dialog box assigns a drive letter with the removable media 
designation; the default is D:. 
2. Right click on Start > Explore to open the Windows NT Exploring pane 
and...

Page 202

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-68 Add IP Interface Assembly 
6
4. Follow the Install Shield procedure to transfer all the necessary files to the 
TN802 IP Interface. 
NOTE:
In the Finish dialog box, select I will restart later. Do not 
select Restart computer.
This would be a good time to read the Readme.txt file.
5. Click on Start > Settings > Control Panel > Services.
6. Select IP Trunk and click on Startup....

Page 203

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-69 Add IP Interface Assembly 
6
Once the system is completely initialized, the LCD reads MEDPRO *.
!WARNING:
When connected remotely via pcANYWHERE, only use the 
pcANYWHERE Restart Host Computer button on the toolbar to 
restart Windows NT.
11. Affix the new TN802B label to the circuit pack.
12. Disconnect the monitor, keyboard, and mouse.
Circuit Pack Verification
1. Type change...

Page 204

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-70 Add TTC Japanese 2-Mbit Trunks 
6
Add TTC Japanese 2-Mbit Trunks
The TN2242 Japan 2-Mbit trunk interconnects DEFINITY to other vendor 
equipment in Japan as well as to other DEFINITY switches through the Time 
Division Multiplexor (TDM).
Installing the trunks 
Determine the port assignment of the trunk from the Trunk Group form.
1. Install a TN2242 circuit pack in assigned carrier...

Page 205

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-71 Adding SCC Port Cabinets 
6
Disable Alarm Origination
1. Type change system-parameters maintenance and press En te r.
2. Set the 
Alarm Origination field to n.
!CAUTION:
If you do not disable Alarm Origination, the system may generate 
alarms, resulting in unnecessary trouble tickets.
3. For some releases of software, disable Cleared Alarm Notification and 
Restart Notification...

Page 206

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-72 Adding SCC Port Cabinets 
6
2. Install cabinet labels on the front and rear of cabinets to the left of the 
circuit pack labels. Label the second cabinet “B”, the third cabinet “C”, and 
the four th cabinet “D”.
Figure 6-23. PPN Cabinet — Front View
Connect TDM or TDM/LAN Cables
1. Disconnect the TDM or TDM/LAN bus terminator from Slot 22 of the control 
cabinet, or from Slot “18”...

Page 207

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-73 Adding SCC Port Cabinets 
6
2.Move the terminator to slot “17” of the top port cabinet. See Figure 6-24, 
Figure 6-25
, or Figure 6-26.
3. Connect the TDM/LAN cables behind the lower rear cover.
Figure 6-24. TDM/LAN Connections for Standard or High Reliability PPN or 
EPN Figure Notes
1. AHF110 TDM/LAN Bus Terminator
2. Slot 17
3. TDM/LAN Cable (WP91716 L3)
4. Slot 00
5. Slot 226....

Page 208

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-74 Adding SCC Port Cabinets 
6
Figure 6-25. TDM/LAN Connections High or Critical Reliability PPN Figure Notes
1. AHF110 TDM/LAN Bus Terminator
2. Slot 17
3. TDM/LAN Cable (WP91716 L3)
4. Slot 00
5. Slot 226. Slot 02
7.Port Cabinet (“D” Position)
8. Port Cabinet (“C” Position)
9. Duplicated Control Cabinet (“B” Position)
10. Control Cabinet (“A” Position) 

Page 209

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-75 Adding SCC Port Cabinets 
6
Figure 6-26. TDM/LAN Connections for Critical Reliability EPN Figure Notes
1. AHF110 TDM/LAN Bus Terminator
2. Slot 17
3. TDM/LAN Cable (WP91716 L3)
4. Slot 00
5. Slot 186. Slot 01 (TDM/LAN Bus Terminator)
7.Port Cabinet (“D” Position)
8. Port Cabinet (“C” Position)
9. Port Cabinet (“B” Position)
10. Expansion Control Cabinet (“A” 
Position) 

Page 210

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-76 Adding SCC Port Cabinets 
6
Connect ICC Cables 
If the new port cabinet is cabinet B” of a critical reliability EPN, install ICC cables. 
1. Connect the cables to the “ICC” block on expansion control cabinet A and 
port cabinet B. Install each cable so the dark stripe on the cable is on the 
bottom. See Table 6-10
, Figure 6-27, and Figure 6-28.
Figure 6-27. ICC Pin-Field Blocks...
Start reading Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual