Adding or Removing Hardware 
6-77 Adding SCC Port Cabinets 
6
Figure 6-28. ICC Pin-Field Blocks on J58890H Port Cabinet
Verify Port Cabinet Address Plugs
The address plug is a jumper field on port cabinets only. The address plug is 
located on the far right hand side of the backplane, to the right of slot 00. 
1. A group of 6 pins is labeled for the cabinet (carrier) jumper connections. 
Verify the address plug...

Page 212

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-78 Adding SCC Port Cabinets 
6
Figure 6-29. Port Cabinet Address Plug Location — Cabinet Rear Figure Notes
1. Address Plug (Shown Set to Carrier D)
2. Carrier B Jumper Location (Default)
3. Carrier C Jumper Location
4. Right Edge of Backplane5. Right Edge of Cabinet
6. Backplane Slot 00
7. To Connector Panel
3
45
1
6
2
7
add_plug CJL 050906 

Page 213

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-79 Adding SCC Port Cabinets 
6
Install Rear Panels
Figure 6-30. Rear Panel Screw Locations
1. Install the rear panels and loosely thread each screw. See Figure 6-30
.
2. For 
unstacked cabinets, tighten the screws securely. 
For a 
stack of cabinets, allow the screws labeled Callout 4 to remain loose. 
These screws are tightened when the ground plates are installed.
3. Be sure the...

Page 214

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-80 Adding SCC Port Cabinets 
6
Install Ground Plates
1. Install ground plates between stacked cabinets to provide the ground 
connection between cabinets, provide radio frequency (RF) radiation 
protection, and help stabilize the cabinets. 
Install Rear Ground Plates (Systems with
Earthquake Protection)
1. Loosen the 4 screws at the bottom of the top cabinet and at the top of the...

Page 215

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-81 Adding SCC Port Cabinets 
6
Figure 6-31. Rear Ground Plate and Front Plate or Cabinet Clip — Side View Figure Notes
1. Front Ground Plate or Cabinet Clip
2. Battery3. Rear Ground Plate
3
2
1
grdpltec LJK 031096 

Page 216

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-82 Adding SCC Port Cabinets 
6
Install Cabinet Clips (Systems without
Earthquake Protection)
A cabinet clip is required between each pair of stacked cabinets. 
1. At the front of the cabinets, install a cabinet clip between each pair of 
cabinets by hooking the clip into the slot of the upper cabinet and snapping 
the straight leg of the clip into the slot on the lower cabinet. See...

Page 217

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-83 Adding SCC Port Cabinets 
6
Install Cable Clamps
1. At the rear of the cabinets, install 2 cable clamps on each ground plate. 
These clamps hold the por t cables.
Install Port Circuit Packs
1. Install circuit packs in the slots specified by the Customer Service 
Document and Port Assignment Worksheet. 
Install Cables
1. Install cables from the port cabinets to the MDF, as...

Page 218

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-84 Adding SCC Port Cabinets 
6
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using DEFINITY 
Enterprise Communications Server Release 8 Maintenance for R8
si. 
Enable Customer Options and Alarm Origination
1. Get the DOSS order number of the upgrade from the project manager and 
ask the regional Customer Software Administration to complete the steps 
in...

Page 219

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-85 Adding Control Cabinet to Release 8si 
6
3. If the SCC cabinet stack contains a TN750/B/C Announcement circuit pack, 
type list configuration software-version and press 
En t e r. If Page 2 of this 
form shows that recorded announcements were saved, these 
announcements can be restored by typing restore announcements and 
pressing 
En t e r.
Adding Control Cabinet to Release 8si...

Page 220

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-86 Adding Control Cabinet to Release 8si 
6
Disable Alarm Origination
1. Type change system-parameters maintenance and press En te r.
2. Set the 
Alarm Origination field to n.
!CAUTION:
If you do not disable Alarm Origination, the system may generate 
alarms, resulting in unnecessary trouble tickets.
3. For some releases of system software, disable Cleared Alarm Notification 
and...