Page 211
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-77 Adding SCC Port Cabinets 6 Figure 6-28. ICC Pin-Field Blocks on J58890H Port Cabinet Verify Port Cabinet Address Plugs The address plug is a jumper field on port cabinets only. The address plug is located on the far right hand side of the backplane, to the right of slot 00. 1. A group of 6 pins is labeled for the cabinet (carrier) jumper connections. Verify the address plug...
Page 212
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-78 Adding SCC Port Cabinets 6 Figure 6-29. Port Cabinet Address Plug Location — Cabinet Rear Figure Notes 1. Address Plug (Shown Set to Carrier D) 2. Carrier B Jumper Location (Default) 3. Carrier C Jumper Location 4. Right Edge of Backplane5. Right Edge of Cabinet 6. Backplane Slot 00 7. To Connector Panel 3 45 1 6 2 7 add_plug CJL 050906
Page 213
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-79 Adding SCC Port Cabinets 6 Install Rear Panels Figure 6-30. Rear Panel Screw Locations 1. Install the rear panels and loosely thread each screw. See Figure 6-30 . 2. For unstacked cabinets, tighten the screws securely. For a stack of cabinets, allow the screws labeled Callout 4 to remain loose. These screws are tightened when the ground plates are installed. 3. Be sure the...
Page 214
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-80 Adding SCC Port Cabinets 6 Install Ground Plates 1. Install ground plates between stacked cabinets to provide the ground connection between cabinets, provide radio frequency (RF) radiation protection, and help stabilize the cabinets. Install Rear Ground Plates (Systems with Earthquake Protection) 1. Loosen the 4 screws at the bottom of the top cabinet and at the top of the...
Page 215
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-81 Adding SCC Port Cabinets 6 Figure 6-31. Rear Ground Plate and Front Plate or Cabinet Clip — Side View Figure Notes 1. Front Ground Plate or Cabinet Clip 2. Battery3. Rear Ground Plate 3 2 1 grdpltec LJK 031096
Page 216
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-82 Adding SCC Port Cabinets 6 Install Cabinet Clips (Systems without Earthquake Protection) A cabinet clip is required between each pair of stacked cabinets. 1. At the front of the cabinets, install a cabinet clip between each pair of cabinets by hooking the clip into the slot of the upper cabinet and snapping the straight leg of the clip into the slot on the lower cabinet. See...
Page 217
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-83 Adding SCC Port Cabinets 6 Install Cable Clamps 1. At the rear of the cabinets, install 2 cable clamps on each ground plate. These clamps hold the por t cables. Install Port Circuit Packs 1. Install circuit packs in the slots specified by the Customer Service Document and Port Assignment Worksheet. Install Cables 1. Install cables from the port cabinets to the MDF, as...
Page 218
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-84 Adding SCC Port Cabinets 6 Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Release 8 Maintenance for R8 si. Enable Customer Options and Alarm Origination 1. Get the DOSS order number of the upgrade from the project manager and ask the regional Customer Software Administration to complete the steps in...
Page 219
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-85 Adding Control Cabinet to Release 8si 6 3. If the SCC cabinet stack contains a TN750/B/C Announcement circuit pack, type list configuration software-version and press En t e r. If Page 2 of this form shows that recorded announcements were saved, these announcements can be restored by typing restore announcements and pressing En t e r. Adding Control Cabinet to Release 8si...
Page 220
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-86 Adding Control Cabinet to Release 8si 6 Disable Alarm Origination 1. Type change system-parameters maintenance and press En te r. 2. Set the Alarm Origination field to n. !CAUTION: If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets. 3. For some releases of system software, disable Cleared Alarm Notification and...