Adding or Removing Hardware 
6-37 Add ISDN—BRI 
6
Add Circuit Packs
1. Determine port assignment of circuit packs to be added.
2. Install the appropriate circuit packs in assigned cabinet slot (as required).
The TN794 Packet Interface circuit pack and the TN556 
or TN2198 ISDN BRI 
circuit pack are required. The TN794 Packet Interface circuit pack should be 
added first. If an EPN is present, a TN570/B/C Expansion...

Page 172

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-38 Add IP Interface Assembly 
6
Add IP Interface Assembly
DEFINITY ECS IP Solutions allows you to send voice and fax from the DEFINITY 
ECS through an Internet protocol (IP) network to other DEFINITY ECSs having 
this feature or to other H.323 V2 compliant endpoints. It is implemented using the 
TN802/B IP Interface, which is a Windows NT server residing on the IP Interface 
Assembly...

Page 173

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-39 Add IP Interface Assembly 
6
Prepare for Installation
Have the following equipment on site before your shipment arrives:
nAC power outlets for the modem and monitor.
nThree unoccupied and adjoining port slots in the DEFINITY ECS for the 
TN802B IP Interface, if needed.
The TN802B occupies only one slot, but it needs the two slots to its left for 
clearance.
nAn additional...

Page 174

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-40 Add IP Interface Assembly 
6
3. Read and follow any directions inserted into the package by the factory.
The TN802B external cable assembly is a bundle of cables with an amphenol 
connector at the end of the bundle and various PC-type connectors (VGA, 
Universal Serial Bus [USB], mouse, keyboard, Ethernet, modem, and COM2) at 
the ends of the individual cables. See Figure 6-15
....

Page 175

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-41 Add IP Interface Assembly 
6
Figure 6-15. TN802B IP Interface External Cable Assembly
Connect the Cables
1. Determine into which port slots you are putting the TN799B C-LAN and 
TN802B IP Interface circuit packs.
NOTE:
Make sure that at least 3 adjacent slots are free for the TN802B.
From the rear of the cabinet:
2. If adding a new TN799B, connect the 259A connector to the...

Page 176

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-42 Add IP Interface Assembly 
6
Connect the Modem
NOTE:
These instructions are for connecting the U.S. Robotics modem supplied to 
U.S. customers only. If using a different modem, follow the manufacturer’s 
instructions on connecting the modem.
1. Connect the RS232 por t of the modem to the MODEM connector of the 
TN802B external cable assembly. 
NOTE:
Check the labels near the...

Page 177

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-43 Add IP Interface Assembly 
6
Connect the Ethernet
1. Connect the network cable to the ETHERNET connector on the TN802B 
external cable assembly.
NOTE:
You need a CAT5 or better cable for 100-Mbyte operation.
Install the Circuit Packs
!CAUTION:
When adding or replacing any hardware, be sure to ground yourself against 
electrostatic discharge (ESD) by wearing a grounded wrist...

Page 178

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-44 Add IP Interface Assembly 
6
NOTE:
The TN799B and TN802B circuit packs are hot-swappable, so you do not 
need to power down the carrier to install them.
If you need to remove the TN802B IP Interface from the carrier at a later 
time, shut down Windows NT first by pressing the recessed reset button on 
the faceplate (see Figure 6-17
) of the TN802B IP Interface until the LCD 
shows...

Page 179

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-45 Add IP Interface Assembly 
6
NOTE:
If replacing the existing TN799 circuit pack, remove it first and replace it with 
the new one.
1. Insert the TN799B circuit pack into the port slot identified earlier.
NOTE:
To properly seat the circuit pack, push firmly on the front of the 
faceplate until the latch reaches the bottom rail of the carrier. Then 
close the latch until it is fully...

Page 180

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-46 Add IP Interface Assembly 
6
Figure 6-18. J58890MA-1 L30
 IP Interface Assembly
Administer the TN799B C-LAN
Refer to the DEFINITY Enterprise Communications Server Administration for 
Network Connectivity
.
Administer the IP Interface
Administration is usually done remotely; call your service representative to start 
the process.
456
789
1
0
1
11
21
3
1
41
51
6
indfmapd KLC 031299 
Start reading Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual

All Lucent Technologies manuals