Page 131

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R7si to R8si 
5-11 Upgrade the Software 
5
2. Type the day in English (Sunday through Saturday) in the Day of the 
Week: field. See Table 5-2
 for English day names. When done, press Ta b 
to move to next field.
3. Type the current month in English (January through December) in the 
Month: field. See Table 5-3
 for English month names. When done, press 
Ta b to move to next field.
4. Type the day of...

Page 132

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R7si to R8si 
5-12 Upgrade the Software 
5
8. Type standard or daylight savings in the Type field, according to the 
current time in the local time zone. For example, if currently on standard 
time, type standard.
9. Type the rule number in the Daylight Savings Rule field.
10. When all the information is correct, press 
En te r.
11. Type display time and press 
En t e r to verify date and time data....

Page 133

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R7si to R8si 
5-13 Upgrade the Software 
5
Enable Scheduled Maintenance
1. Type change system-parameters maintenance and press En t e r to enable 
the scheduled daily maintenance.
2. Check the Start Time and Stop Time fields.
Enable Customer Options and Alarm Origination
1. Get the DOSS order number of the upgrade from the project manager and 
ask the regional Customer Software Administration to complete...

Page 134

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R7si to R8si 
5-14 Upgrade the Software 
5
Check Link Status
1. Type display communication-interface links and press En t e r. 
2. Type status link 
number and press En t e r. Verify that the service 
status field is set to in service. Repeat this step for each link.
Save Translations
1. Type save translation and press En t e r to copy upgraded translations in 
memory to the translation card, which takes...

Page 135

Adding or Removing Hardware 
6-1 Add Circuit Packs 
6
DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
6
Adding or Removing Hardware
This chapter details the information required to install some equipment associated 
with upgrading an existing system. 
For more information about installing cabinets, refer to DEFINITY Enterprise 
Communications Server Release 8 Installation and Test for Single-Carrier 
Cabinets.
For more information about installing adjuncts and...

Page 136

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-2 List of Circuit Packs 
6
List of Circuit Packs 
Table 6-1 lists the c irc uit p ac ks sorted  b y ap p aratus c od e, inc lud ing c irc uit 
p ac ks used  in non-United  States installations.
Table 6-1. Circuit Packs and Circuit Modules 
Apparatus Code Name Type
631DA1 AC Power Unit Power
631DB1 AC Power Unit Power
644A1 DC Power Unit Power
645B1 DC Power Unit Power
649A DC Power...

Page 137

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-3 List of Circuit Packs 
6
TN458 Tie Trunk - U.K. Port
TN459B Direct Inward Dialing Trunk Port
TN464C/D/E/F DS1 Interface - T1, 24 Channel - E1, 32 Channel Port
TN465/B/C Central Office Trunk Port
TN467 Analog Line Port
TN468B Analog Line Port
TN479 Analog Line Port
TN497 Tie Trunk - Italy Port
TN553 Packet Data Line Port
TN556B/C/D ISDN-BRI 4-Wire S/T-NT Interface Port
TN570/B/C...

Page 138

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-4 List of Circuit Packs 
6
TN773 Processor Control
TN775/B/C Maintenance Service
TN776 Expansion Interface Port
TN780 Tone-Clock Control
TN786/B Processor Control
TN787F/G/H/J/K Multimedia Interface Service
TN788B Multimedia Voice Conditioner  Service
TN789 Radio Controller Control
TN790/B Processor Control
TN792 Duplication Interface (DUPINT) Control
TN793 Analog Line (24-port)...

Page 139

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-5 Installing Fiber Optic Cable Pass-Thru Kit (SCC) 
6
Installing Fiber Optic Cable Pass-Thru 
Kit (SCC)
This section details the installation of the DEFINITY fiber optic pass-thru kit for 
Single-Carrier Cabinets (SCC) only. This kit (comcode 848029278) provides the 
equipment necessary to install the fiber optic connectors and associated cabling. 
Unpack and Inspect
1. Verify the...

Page 140

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-6 Installing Fiber Optic Cable Pass-Thru Kit (SCC) 
6
Figure 6-1. Fiber Pass-Thru Kit EquipmentFigure Notes
1. Pass-thru Tool
2. SC-SC Fiber Optic Adapter
3. ST-SC Fiber Optic Adapter
4. Fiber Optic Cable5. Fiber Optic Cable Disconnect Label
6. I/O Connector Adapter Bracket
7. Cable Tie
8. Cable Tie Mount
indapkit RPY 012398
1
2
3
4
5
6
7
8 