Page 131
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R7si to R8si 5-11 Upgrade the Software 5 2. Type the day in English (Sunday through Saturday) in the Day of the Week: field. See Table 5-2 for English day names. When done, press Ta b to move to next field. 3. Type the current month in English (January through December) in the Month: field. See Table 5-3 for English month names. When done, press Ta b to move to next field. 4. Type the day of...
Page 132
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R7si to R8si 5-12 Upgrade the Software 5 8. Type standard or daylight savings in the Type field, according to the current time in the local time zone. For example, if currently on standard time, type standard. 9. Type the rule number in the Daylight Savings Rule field. 10. When all the information is correct, press En te r. 11. Type display time and press En t e r to verify date and time data....
Page 133
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R7si to R8si 5-13 Upgrade the Software 5 Enable Scheduled Maintenance 1. Type change system-parameters maintenance and press En t e r to enable the scheduled daily maintenance. 2. Check the Start Time and Stop Time fields. Enable Customer Options and Alarm Origination 1. Get the DOSS order number of the upgrade from the project manager and ask the regional Customer Software Administration to complete...
Page 134
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R7si to R8si 5-14 Upgrade the Software 5 Check Link Status 1. Type display communication-interface links and press En t e r. 2. Type status link number and press En t e r. Verify that the service status field is set to in service. Repeat this step for each link. Save Translations 1. Type save translation and press En t e r to copy upgraded translations in memory to the translation card, which takes...
Page 135
Adding or Removing Hardware 6-1 Add Circuit Packs 6 DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 6 Adding or Removing Hardware This chapter details the information required to install some equipment associated with upgrading an existing system. For more information about installing cabinets, refer to DEFINITY Enterprise Communications Server Release 8 Installation and Test for Single-Carrier Cabinets. For more information about installing adjuncts and...
Page 136
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-2 List of Circuit Packs 6 List of Circuit Packs Table 6-1 lists the c irc uit p ac ks sorted b y ap p aratus c od e, inc lud ing c irc uit p ac ks used in non-United States installations. Table 6-1. Circuit Packs and Circuit Modules Apparatus Code Name Type 631DA1 AC Power Unit Power 631DB1 AC Power Unit Power 644A1 DC Power Unit Power 645B1 DC Power Unit Power 649A DC Power...
Page 137
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-3 List of Circuit Packs 6 TN458 Tie Trunk - U.K. Port TN459B Direct Inward Dialing Trunk Port TN464C/D/E/F DS1 Interface - T1, 24 Channel - E1, 32 Channel Port TN465/B/C Central Office Trunk Port TN467 Analog Line Port TN468B Analog Line Port TN479 Analog Line Port TN497 Tie Trunk - Italy Port TN553 Packet Data Line Port TN556B/C/D ISDN-BRI 4-Wire S/T-NT Interface Port TN570/B/C...
Page 138
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-4 List of Circuit Packs 6 TN773 Processor Control TN775/B/C Maintenance Service TN776 Expansion Interface Port TN780 Tone-Clock Control TN786/B Processor Control TN787F/G/H/J/K Multimedia Interface Service TN788B Multimedia Voice Conditioner Service TN789 Radio Controller Control TN790/B Processor Control TN792 Duplication Interface (DUPINT) Control TN793 Analog Line (24-port)...
Page 139
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-5 Installing Fiber Optic Cable Pass-Thru Kit (SCC) 6 Installing Fiber Optic Cable Pass-Thru Kit (SCC) This section details the installation of the DEFINITY fiber optic pass-thru kit for Single-Carrier Cabinets (SCC) only. This kit (comcode 848029278) provides the equipment necessary to install the fiber optic connectors and associated cabling. Unpack and Inspect 1. Verify the...
Page 140
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-6 Installing Fiber Optic Cable Pass-Thru Kit (SCC) 6 Figure 6-1. Fiber Pass-Thru Kit EquipmentFigure Notes 1. Pass-thru Tool 2. SC-SC Fiber Optic Adapter 3. ST-SC Fiber Optic Adapter 4. Fiber Optic Cable5. Fiber Optic Cable Disconnect Label 6. I/O Connector Adapter Bracket 7. Cable Tie 8. Cable Tie Mount indapkit RPY 012398 1 2 3 4 5 6 7 8