Page 151
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-17 Installing Fiber Optic Cable Pass-Thru Kit (SCC) 6 Figure 6-11. Install the Rear Panels 15. Replace the front cover panel. 16. Discard the pass-thru tool. Test the Installation 1. Log into the management terminal. 2. Administer the system by referring to the ATM section. 3. Type list configuration all and press En t e r to determine if the new circuit pack appears in the...
Page 152
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-18 Adding External Modem to EPN 6 Adding External Modem to EPN U.S. Robotics Model 839 External Modem Figure 6-12. Connect External Modem to EPN 1. Connect an RS-232 cable to the modem. See Figure 6-12 . NOTE: The following steps refer to a PC or laptop with Windows 95 or Windows NT 4.0. Use the Hyperterminal (terminal emulation) application. 2. Connect the opposite end of the...
Page 153
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-19 Add CO, FX, WATS, and PCOL 6 Add CO, FX, WATS, and PCOL Requirements Each Central Office (CO), Foreign Exchange (FX), Personal Central Office Line (PCOL), or Wide Area Telecommunications Service (WATS) trunk connects to 1 port of either an 8-port TN747B or TN797 or to 1 of several CO trunk circuit packs. Installation 1. Determine the port assignment of the trunk from the Trunk...
Page 154
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-20 Add Tie Trunks 6 2. Install a DID Trunk circuit pack in assigned carrier slot (if an additional circuit pack is required). 3.Administer forms listed under “DID Trunk Group” in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Add Tie Trunks Requirements Each tie trunk connects to 1 port of a 4-port tie trunk circuit pack or to an assortment of...
Page 155
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-21 Add DS1 Tie and OPS 6 Figure 6-13. Tie Trunk Circuit Packs (Component Side) Add DS1 Tie and OPS The TN722B DS1 Tie Trunk and TN767B (or later) DS1 Interface circuit packs provide connections to a 1.544-Mbps DS1 facility (T1) as 24 independent 64-kbps trunks. The TN722B DS1 Tie Trunk, and TN464C (or later) DS1 Interface circuit packs provide connections to a 2.048-Mbps DS1...
Page 156
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-22 Add Speech Synthesis 6 Service Interruption 1. Since the addition of DS1 tie-trunk service may require a service interruption, notify the customer in advance as to when the addition will occur. 2. For information about administering DS1 Tie Trunks, refer to DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Add Speech Synthesis The Speech Synthesizer...
Page 157
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-23 Add Pooled Modem 6 The pooled modem requires a Lucent WP90110 L7 power supply. Although integrated conversion can use either the L5 or L7, the combined only works with an L7. !CAUTION: The L5 and L7 power supplies look identical. Check the label to be sure you have the L7 before installing. 1. Determine the port assignment of the circuit packs to be added (if required). 2....
Page 158
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-24 Add Multiple Integrated Recorded Announcement 6 Settings for Modem Connected to the Data Terminal Equipment (DTE) 1. Type add station next and press En te r. 2. Type 2500 in the Type field. 3. Type the port assignment in the Port field and press En t e r. Add Multiple Integrated Recorded Announcement TN750C circuit packs are required if the system has multiple announcement...
Page 159
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-25 Add Multiple Integrated Recorded Announcement 6 Save and Restore Recorded Announcements !CAUTION: If the yellow LED is flashing, do not remove the circuit pack, as this will corrupt the announcement data. 1. Type save announcements and press En t e r. 2. To restore announcements, type restore announcements to and press En te r. After 5 minutes (with no alterations to...
Page 160
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-26 Add Multiple Integrated Recorded Announcement 6 3. Type add data-module next and press En te r to administer a new data module on the TN750C. 4. Type announcement in the Type field. 5. Type the location in the Board field and submit the form. 6. Type restore announcements for the TN750C. Wait until announcements copy from voice RAM to flash memory (yellow LED on the TN750C...