Page 151

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-17 Installing Fiber Optic Cable Pass-Thru Kit (SCC) 
6
Figure 6-11. Install the Rear Panels
15. Replace the front cover panel.
16. Discard the pass-thru tool.
Test the Installation
1. Log into the management terminal.
2. Administer the system by referring to the ATM section.
3. Type list configuration all and press 
En t e r to determine if the new circuit 
pack appears in the...

Page 152

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-18 Adding External Modem to EPN 
6
Adding External Modem to EPN
U.S. Robotics Model 839 External Modem
Figure 6-12. Connect External Modem to EPN
1. Connect an RS-232 cable to the modem. See Figure 6-12
.
NOTE:
The following steps refer to a PC or laptop with Windows 95 or 
Windows NT 4.0. Use the Hyperterminal (terminal emulation) 
application. 
2. Connect the opposite end of the...

Page 153

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-19 Add CO, FX, WATS, and PCOL 
6
Add CO, FX, WATS, and PCOL
Requirements
Each Central Office (CO), Foreign Exchange (FX), Personal Central Office Line 
(PCOL), or Wide Area Telecommunications Service (WATS) trunk connects to 1 
port of either an 8-port TN747B or TN797 or to 1 of several CO trunk circuit packs. 
Installation
1. Determine the port assignment of the trunk from the Trunk...

Page 154

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-20 Add Tie Trunks 
6
2. Install a DID Trunk circuit pack in assigned carrier slot (if an additional 
circuit pack is required).
3.Administer forms listed under “DID Trunk Group” in 
DEFINITY Enterprise 
Communications Server Release 8 Administrator’s Guide
.
Add Tie Trunks
Requirements
Each tie trunk connects to 1 port of a 4-port tie trunk circuit pack or to an 
assortment of...

Page 155

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-21 Add DS1 Tie and OPS 
6
Figure 6-13. Tie Trunk Circuit Packs (Component Side)
Add DS1 Tie and OPS
The TN722B DS1 Tie Trunk and TN767B (or later) DS1 Interface circuit packs 
provide connections to a 1.544-Mbps DS1 facility (T1) as 24 independent 
64-kbps trunks. 
The TN722B DS1 Tie Trunk, and TN464C (or later) DS1 Interface circuit packs 
provide connections to a 2.048-Mbps DS1...

Page 156

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-22 Add Speech Synthesis 
6
Service Interruption
1. Since the addition of DS1 tie-trunk service may require a service 
interruption, notify the customer in advance as to when the addition will 
occur.
2. For information about administering DS1 Tie Trunks, refer to 
DEFINITY 
Enterprise Communications Server Release 8 Administrator’s Guide
.
Add Speech Synthesis
The Speech Synthesizer...

Page 157

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-23 Add Pooled Modem 
6
The pooled modem requires a Lucent WP90110 L7 power supply. Although 
integrated conversion can use either the L5 or L7, the combined only works with 
an L7.
!CAUTION:
The L5 and L7 power supplies look identical. Check the label to be sure you 
have the L7 before installing.
1. Determine the port assignment of the circuit packs to be added (if 
required).
2....

Page 158

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-24 Add Multiple Integrated Recorded Announcement 
6
Settings for Modem Connected to the Data
Terminal Equipment (DTE)
1. Type add station next and press En te r.
2. Type 2500 in the Type field.
3. Type the port assignment in the Port field and press 
En t e r.
Add Multiple Integrated Recorded 
Announcement
TN750C circuit packs are required if the system has multiple announcement...

Page 159

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-25 Add Multiple Integrated Recorded Announcement 
6
Save and Restore Recorded Announcements
!CAUTION:
If the yellow LED is flashing, do not remove the circuit pack, as this will 
corrupt the announcement data.
1. Type save announcements    and press 
En t e r. 
2. To restore announcements, type restore announcements  to    and press 
En te r.
After 5 minutes (with no alterations to...

Page 160

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-26 Add Multiple Integrated Recorded Announcement 
6
3. Type add data-module next and press En te r to administer a new data 
module on the TN750C. 
4. Type announcement in the Type field.
5. Type the location in the Board field and submit the form.
6. Type restore announcements  for the TN750C.
Wait until announcements copy from voice RAM to flash memory (yellow 