Page 101
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-3 Read this First 4 Software Upgrade Although the translations upgrade automatically to Release 8, several features require special attention because of screen changes or potential naming conflicts in the update or upgrade procedure. Between customer confirmation and the actual update or upgrade, check the screens to ensure the translations meet the customer’s...
Page 102
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-4 Read this First 4 Required Hardware The equipment in Table 4-1 must be on site before the upgrade begins. To place a claim for missing equipment, as part of the Streamlined Implementation process, call 1-800-772-5409, or the number provided by your Lucent Technologies representative. Table 4-1. Required Hardware Quantity Equipment Description Standard...
Page 103
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-5 Task Table 4 Ta s k Ta b l e Table 4-2 lists the high-level tasks to perform the upgrades. Refer to the appropriate page for instructions for each step. The upgrade procedure is similar for both the standard and high or critical reliability system with a few exceptions. These exceptions are noted as you go through the steps. Table 4-2. Tasks to upgrade the...
Page 104
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-6 Upgrade the Software and Hardware 4 Upgrade the Software and Hardware Check SPE Ty p e status system 1 and press En te r to check the health of the system. Disable Scheduled Maintenance and Alarm Origination to INADS 1. Type change system-parameters maintenance and press En te r to prevent scheduled daily maintenance from interfering with the update or...
Page 105
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-7 Upgrade the Software and Hardware 4 3. Type neither in the Alarm Origination to OSS Numbers field and press En t e r . NOTE: For some software loads, set the Cleared Alarm Notification and Restart Notification fields to disable before pressing En t e r. Disable TTI NOTE: Do this step only if the Terminal Translation Initialization (TTI) is disabled and you...
Page 106
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-8 Upgrade the Software and Hardware 4 !WARNING: Translation corruption detected; call Lucent Technologies distributor immediately. NOTE: The save translation command cannot function if the translation corruption message appears. Refer to ‘‘Translation Corruption Detected’’ on page B-5 to clear the problem. NOTE: This translation card may or not be used in the...
Page 107
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-9 Upgrade the Software and Hardware 4 10. Type change communication-interface processor-channels and press En t e r. 11. For each processor channel where the Application field is set to ISDN, clear all fields and press En t e r. 12. Type change communication-interface links and press En t e r. 13. For each PI extension where the Prot field is set to ISDN: a....
Page 108
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-10 Upgrade the Software and Hardware 4 Verify Software Version If standard reliability: 1. Type list configuration software-version and press En t e r. Under the UPDATE FILE column, note whether any patches have been applied. NOTE: If you restore the system to the old software, you must download these patches onto the system. Check Translations Date field to...
Page 109
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-11 Upgrade the Software and Hardware 4 Power Down the Control Cabinet !CAUTION: Powering down the control cabinet causes important system data, such as BCMS data, records of queued ACD calls, Automatic Wakeup request, and Do Not Disturb requests, to be lost. 1. Set the circuit breaker to OFF. NOTE: On a Single-Carrier Cabinet, the breaker is on the back. On a...
Page 110
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-12 Upgrade the Software and Hardware 4 For high or critical reliability: 6. Remove the TN772 Duplication Interface circuit packs and place them in antistatic packing material. NOTE: Leave the existing duplication cables connected to the backplane. The fiber optic cable connecting the new TN792 Duplication Interface circuit packs does not replace these cables....