DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R5vs/R6vs to R8si 
2-19 Upgrade to Release 8si 
2
Power Up the System
1. Set the cabinet circuit breaker to ON. The system performs the reset 
level 4 reboot process and loads translations from the translation card. This 
takes about 10 minutes.
2. Affix the new TN790B circuit pack position label (designation strip) to the 
front of the cabinet.
Administer the System
1. Log in as craft at the login:...

Page 72

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R5vs/R6vs to R8si 
2-20 Upgrade to Release 8si 
2
2. Type the appropriate start and stop information in the Change Day, 
Month, Date, Time, and Increment (for example, 1:00 equals one hour) 
fields for each rule. 
NOTE:
You can change any rule except rule 0 (zero). You cannot delete a 
daylight savings rule if it is in use on either the Locations or Date and 
Time screens.
3. When done, press 
En t e r....

Page 73

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R5vs/R6vs to R8si 
2-21 Upgrade to Release 8si 
2
2. Type the day in English (Sunday through Saturday) in the Day of the 
Week: field. See Table 2-5
 for English day names. When done, press Ta b 
to move to next field.
3. Type the current month in English (January through December) in the 
Month: field. See Table 2-6
 for English month names. When done, press 
Ta b to move to next field.
4. Type the day...

Page 74

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R5vs/R6vs to R8si 
2-22 Upgrade to Release 8si 
2
8. Type standard or daylight savings in the Type field, according to the 
current time in the local time zone. For example, if currently on standard 
time, type standard.
9. Type the rule number in the Daylight Savings Rule field.
10. When all the information is correct, press 
En te r.
11. Type display time and press 
En t e r to verify date and time...

Page 75

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R5vs/R6vs to R8si 
2-23 Upgrade to Release 8si 
2
Resolve Alarms
1. Type display alarms and press En te r to examine the alarm log. Resolve 
any alarms that may exist using 
DEFINITY Enterprise Communications 
Server Maintenance for R8si
. 
Check Link Status
1. Type display communication-interface links and press En t e r. 
2. Type status link 
number and press En t e r. Repeat this step for each link....

Page 76

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R5vs/R6vs to R8si 
2-24 Upgrade to Release 8si 
2
Save Translations
1. Type save translation and press En t e r to copy upgraded translations in 
memory to the upgraded translation card, which takes about 10 minutes.
Restore Announcements (if necessary)
1. Type restore announcements and press En t e r to copy announcements 
from the upgraded translation flashcard to memory, which takes about 40...

Page 77

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R5vs/R6vs to R8si 
2-25 Upgrade to Release 8si 
2
Display Memory-Configuration
1. Log in as craft. If the Translation Corruption Detected message 
appears, refer to ‘‘Translation Corruption Detected’’ on page B-5
.
2. Type display memory-configuration and press 
En te r. Check the total 
DRAM field. SIMM field “A” must contain a 16. 
Disassemble the G3vs System
1. Remove any unused 25-pair cables from...

Page 78

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading R5vs/R6vs to R8si 
2-26 Upgrade to Release 8si 
2
Figure 2-4. Exploded View of G3vs System
Return Replaced Equipment
1. Return replaced equipment to Lucent Technologies according to the 
requirements outlined in:
BCS/Material Logistics, MSL/Attended Stocking Locations
Methods and Procedures for Basic Material Returns
2. If the original translation card is not being used with the Release 8 
software,...

Page 79

Upgrading G3s/si (w/Intel 386) to R8si 
3-1 Read this First 
3
DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
3
Upgrading G3s/si (w/Intel 386) to R8si
This chapter provides the information necessary to upgrade a DEFINITY ECS 
System with a TN786B processor to a Release 8si. 
NOTE:
This chapter assumes that the current system contains an Intel 386® 
processor. If the system is not at this level, refer to 
DEFINITY 
Communications System Generic 3vs and Generic...

Page 80

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-2 Read this First 
3
Call Management System (CMS)
The CMS link is dropped and restarted during the upgrade. This causes CMS 
data to be lost. This data loss can be minimized if the upgrade is performed just 
after the last CMS measurement interval.
All measurement data is lost during the upgrade (including BCMS). If needed, the 
repor ts may be printed before the upgrade...
Start reading Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual

All Lucent Technologies manuals