Page 71
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-19 Upgrade to Release 8si 2 Power Up the System 1. Set the cabinet circuit breaker to ON. The system performs the reset level 4 reboot process and loads translations from the translation card. This takes about 10 minutes. 2. Affix the new TN790B circuit pack position label (designation strip) to the front of the cabinet. Administer the System 1. Log in as craft at the login:...
Page 72
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-20 Upgrade to Release 8si 2 2. Type the appropriate start and stop information in the Change Day, Month, Date, Time, and Increment (for example, 1:00 equals one hour) fields for each rule. NOTE: You can change any rule except rule 0 (zero). You cannot delete a daylight savings rule if it is in use on either the Locations or Date and Time screens. 3. When done, press En t e r....
Page 73
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-21 Upgrade to Release 8si 2 2. Type the day in English (Sunday through Saturday) in the Day of the Week: field. See Table 2-5 for English day names. When done, press Ta b to move to next field. 3. Type the current month in English (January through December) in the Month: field. See Table 2-6 for English month names. When done, press Ta b to move to next field. 4. Type the day...
Page 74
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-22 Upgrade to Release 8si 2 8. Type standard or daylight savings in the Type field, according to the current time in the local time zone. For example, if currently on standard time, type standard. 9. Type the rule number in the Daylight Savings Rule field. 10. When all the information is correct, press En te r. 11. Type display time and press En t e r to verify date and time...
Page 75
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-23 Upgrade to Release 8si 2 Resolve Alarms 1. Type display alarms and press En te r to examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Maintenance for R8si . Check Link Status 1. Type display communication-interface links and press En t e r. 2. Type status link number and press En t e r. Repeat this step for each link....
Page 76
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-24 Upgrade to Release 8si 2 Save Translations 1. Type save translation and press En t e r to copy upgraded translations in memory to the upgraded translation card, which takes about 10 minutes. Restore Announcements (if necessary) 1. Type restore announcements and press En t e r to copy announcements from the upgraded translation flashcard to memory, which takes about 40...
Page 77
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-25 Upgrade to Release 8si 2 Display Memory-Configuration 1. Log in as craft. If the Translation Corruption Detected message appears, refer to ‘‘Translation Corruption Detected’’ on page B-5 . 2. Type display memory-configuration and press En te r. Check the total DRAM field. SIMM field “A” must contain a 16. Disassemble the G3vs System 1. Remove any unused 25-pair cables from...
Page 78
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-26 Upgrade to Release 8si 2 Figure 2-4. Exploded View of G3vs System Return Replaced Equipment 1. Return replaced equipment to Lucent Technologies according to the requirements outlined in: BCS/Material Logistics, MSL/Attended Stocking Locations Methods and Procedures for Basic Material Returns 2. If the original translation card is not being used with the Release 8 software,...
Page 79
Upgrading G3s/si (w/Intel 386) to R8si 3-1 Read this First 3 DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 3 Upgrading G3s/si (w/Intel 386) to R8si This chapter provides the information necessary to upgrade a DEFINITY ECS System with a TN786B processor to a Release 8si. NOTE: This chapter assumes that the current system contains an Intel 386® processor. If the system is not at this level, refer to DEFINITY Communications System Generic 3vs and Generic...
Page 80
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-2 Read this First 3 Call Management System (CMS) The CMS link is dropped and restarted during the upgrade. This causes CMS data to be lost. This data loss can be minimized if the upgrade is performed just after the last CMS measurement interval. All measurement data is lost during the upgrade (including BCMS). If needed, the repor ts may be printed before the upgrade...