Page 51
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-25 Upgrade to Release 8si 1 Figure 1-4. Exploded View of G3vs System Return Replaced Equipment 1. Return replaced equipment to Lucent Technologies according to the requirements outlined in: BCS/Material Logistics, MSL/Attended Stocking Locations Methods and Procedures for Basic Material Returns 2. If the original translation card is not being used with the Release 8...
Page 52
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-26 DEFINITY AUDIX Power Procedures 1 DEFINITY AUDIX Power Procedures If the AUDIX System is located in the DEFINITY cabinet, then follow these procedures. Power Down the AUDIX System A yellow caution sticker on the system’s power unit notifies technicians to shut down the DEFINITY AUDIX System prior to powering down the system. 1. Log into the AUDIX System as craft. 2....
Page 53
Upgrading R5vs/R6vs to R8si 2-1 2 DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 2 Upgrading R5vs/R6vs to R8si This chapter provides the information necessary to upgrade a G3vs with a TN790 processor to a Release 8si. This upgrade requires replacing the existing cabinet with a new Single-Carrier Control Cabinet. The port circuit packs from the present system may be reused only if a site inspection determines that the port circuit pack vintages are...
Page 54
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-2 Read This First 2 Read This First Service Interruption The upgrade process for a standard reliability system requires a service interruption. Coordinate the service interruption with the customer and the local account team. Call Management System (CMS) The CMS link is dropped and restarted during the upgrade. This causes CMS data to be lost. This data loss can be minimized if...
Page 55
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-3 Read This First 2 Between customer confirmation and the actual update or upgrade, check the screens to ensure the translations meet the customer’s needs. After rebooting the system, enter the translations either locally or remotely. If done remotely, Contact Field Support Administration Center (FSAC) for the remote entry. For information to make the required changes, refer...
Page 56
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-4 Read This First 2 Required Hardware The equipment in Table 2-1 must be on-site before the upgrade begins. To place a claim for missing equipment, as part of the Streamlined Implementation process, call 1-800-772-5409, or the number provided by your Lucent Technologies representative. Table 2-1. Required Hardware Equipment Description Quantity J58890L-1 L5 Single Carrier Control...
Page 57
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-5 Read This First 2 Table 2-2. Carriers that use the TN794 NetCon circuit pack DEFINITY R7.1 or later Carrier/Backplane Equipment Notes SCC Processor Cabinet J58890L-2 List 25 This replaces List 10 SCC Processor Cabinet (Survivable Remote)J58890L-2 List 31 This replaces List 30 SCC Processor Cabinet (Knock Down)J58890L-2 List 52 This replaces List 51 Backplane for the...
Page 58
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-6 Task Table 2 Ta s k Ta b l e Table 2-3 provides the high-level tasks to perform the upgrades. Refer to the appropriate page for instructions for each step. Table 2-3. Tasks to Upgrade to Release 8si áTask Description Page Unpack and Inspect Control Cabinet2-7 Install Control Cabinet2-8 Add Earthquake Protection2-8 Label Existing Cables2-8 Install TDM/LAN Bus Terminators2-9 Swing...
Page 59
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-7 Upgrade to Release 8si 2 Upgrade to Release 8si Unpack and Inspect Control Cabinet 1. Unpack J58890L-1 L5 Single-Carrier Control Cabinet and verify comcode vintage of the control carrier. !CAUTION: Take care to avoid injury while cutting and removing bands. NOTE: Verify the vintage of the control carrier and check it against Table 2-2. If your carrier is NOT listed, you need...
Page 60
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5vs/R6vs to R8si 2-8 Upgrade to Release 8si 2 Install Control Cabinet 1. Position the control cabinet at the desired location (as close to the Main Distribution Frame [MDF] as possible). !CAUTION: The cabinet may weigh as much as 130 pounds (58 kg). Use lifting precautions to avoid injury. 2. If earthquake protection is not required, install hole plugs (provided with cabinet) in the holes...