Page 41
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-15 Upgrade to Release 8si 1 Remove Ground Connections 1. Remove the 6 AWG (#40) (16 mm2) ground wire from the ground block on the rear of the G3vs system. This wire later attaches to the new control cabinet. 2. Remove the 10 AWG (#25) (6 mm 2) Coupled Bonding Conductor (CBC) wire from the ground block on the rear of the G3vs system. This wire later attaches to the new...
Page 42
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-16 Upgrade to Release 8si 1 NOTE: A TN2182 Tone-Cloc k c an rep lac e the TN756 Tone-Detec tor/ Generator. If using a TN2182, you do not need a TN748B Tone-Detector. 5. Install the circuit packs into the appropriate port slots in the control cabinet. Because the new control cabinet has more port slots than the G3vs cabinet, you should not need to retranslate these...
Page 43
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-17 Upgrade to Release 8si 1 Connect Control Cabinet Power and Ground 1. Connect the 6 AWG (#40) (16 mm2) wire (previously used on the G3vs cabinet) from the single-point ground block on the control cabinet to the approved ground. See Figure 1-3 . Figure 1-3. Typical AC Power and Ground Layout 2. Connect the 10 AWG (#25) (6 mm 2) wire (previously used on the G3vs...
Page 44
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-18 Upgrade to Release 8si 1 Power Up the System 1. Set the cabinet circuit breaker to ON. The system performs the reset level 4 reboot process and loads translations from the translation card, which takes about 10 minutes. Administer the System 1. Log in as craft at the login: prompt. 2. Check for the Translation Corruption Detected message before proceeding with the...
Page 45
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-19 Upgrade to Release 8si 1 2. Type the appropriate start and stop information in the Change Day, Month, Date, Time, and Increment (for example, 1:00 equals one hour) fields for each rule. NOTE: You can change any rule except rule 0 (zero). You cannot delete a daylight savings rule if it is in use on either the Locations or Date and Time screens. 3. When done, press...
Page 46
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-20 Upgrade to Release 8si 1 2. Type the day in English (Sunday through Saturday) in the Day of the Week: field. See Table 1-5 for English day names. When done, press Ta b to move to next field. 3. Type the current month in English (January through December) in the Month: field. See Table 1-6 for English month names. When done, press Ta b to move to next field. 4. Type...
Page 47
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-21 Upgrade to Release 8si 1 8. Type standard or daylight savings in the Type field, according to the current time in the local time zone. For example, if currently on standard time, type standard. 9. Type the rule number in the Daylight Savings Rule field. 10. When all the information is correct, press En te r. 11. Type display time and press En t e r to verify date and...
Page 48
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-22 Upgrade to Release 8si 1 Resolve Alarms 1. Type display alarms and press En te r to examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Maintenance for R8si . Check Link Status 1. Type display communication-interface links and press En t e r. 2. Type status link number and press En t e r. Repeat this step for...
Page 49
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-23 Upgrade to Release 8si 1 Save Translations 1. Type save translation and press En t e r to copy upgraded translations in memory to the upgraded translation card, which takes about 10 minutes. Restore Announcements (if necessary) 1. Type restore announcements and press En t e r to copy announcements from the upgraded translation flashcard to memory, which takes about 40...
Page 50
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3vs (w/Intel 386) to R8si 1-24 Upgrade to Release 8si 1 Display Memory-Configuration 1. Log in as craft. If the Translation Corruption Detected message appears, refer to ‘‘Translation Corruption Detected’’ on page B-5 . 2. Type display memory-configuration and press En te r. Check the total DRAM field. SIMM field “A” must contain a 16. Disassemble the G3vs System 1. Remove any unused 25-pair...