Page 41

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-15 Upgrade to Release 8si 
1
Remove Ground Connections
1. Remove the 6 AWG (#40) (16 mm2) ground wire from the ground block on 
the rear of the G3vs system. This wire later attaches to the new control 
cabinet.
2. Remove the 10 AWG (#25) (6 mm
2) Coupled Bonding Conductor (CBC) 
wire from the ground block on the rear of the G3vs system. This wire later 
attaches to the new...

Page 42

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-16 Upgrade to Release 8si 
1
 
NOTE:
A TN2182 Tone-Cloc k c an rep lac e the TN756 Tone-Detec tor/ 
Generator. If using  a TN2182, you do not need  a TN748B 
Tone-Detector.
5. Install the circuit packs into the appropriate port slots in the control cabinet. 
Because the new control cabinet has more port slots than the G3vs 
cabinet, you should not need to retranslate these...

Page 43

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-17 Upgrade to Release 8si 
1
Connect Control Cabinet Power and Ground
1. Connect the 6 AWG (#40) (16 mm2) wire (previously used on the G3vs 
cabinet) from the single-point ground block on the control cabinet to the 
approved ground. See Figure 1-3
. 
Figure 1-3. Typical AC Power and Ground Layout 
2. Connect the 10 AWG (#25) (6 mm
2) wire (previously used on the G3vs...

Page 44

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-18 Upgrade to Release 8si 
1
Power Up the System
1. Set the cabinet circuit breaker to ON. The system performs the reset 
level 4 reboot process and loads translations from the translation card, 
which takes about 10 minutes.
Administer the System
1. Log in as craft at the login: prompt. 
2. Check for the Translation Corruption Detected message before 
proceeding with the...

Page 45

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-19 Upgrade to Release 8si 
1
2. Type the appropriate start and stop information in the Change Day, 
Month, Date, Time, and Increment (for example, 1:00 equals one hour) 
fields for each rule. 
NOTE:
You can change any rule except rule 0 (zero). You cannot delete a 
daylight savings rule if it is in use on either the Locations or Date and 
Time screens.
3. When done, press...

Page 46

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-20 Upgrade to Release 8si 
1
2. Type the day in English (Sunday through Saturday) in the Day of the 
Week: field. See Table 1-5
 for English day names. When done, press Ta b 
to move to next field.
3. Type the current month in English (January through December) in the 
Month: field. See Table 1-6
 for English month names. When done, press 
Ta b to move to next field.
4. Type...

Page 47

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-21 Upgrade to Release 8si 
1
8. Type standard or daylight savings in the Type field, according to the 
current time in the local time zone. For example, if currently on standard 
time, type standard.
9. Type the rule number in the Daylight Savings Rule field.
10. When all the information is correct, press 
En te r.
11. Type display time and press 
En t e r to verify date and...

Page 48

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-22 Upgrade to Release 8si 
1
Resolve Alarms
1. Type display alarms and press En te r to examine the alarm log. Resolve 
any alarms that may exist using 
DEFINITY Enterprise Communications 
Server Maintenance for R8si
. 
Check Link Status
1. Type display communication-interface links and press En t e r. 
2. Type status link 
number and press En t e r. Repeat this step for...

Page 49

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-23 Upgrade to Release 8si 
1
Save Translations
1. Type save translation and press En t e r to copy upgraded translations in 
memory to the upgraded translation card, which takes about 10 minutes.
Restore Announcements (if necessary)
1. Type restore announcements and press En t e r to copy announcements 
from the upgraded translation flashcard to memory, which takes about 40...

Page 50

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-24 Upgrade to Release 8si 
1
Display Memory-Configuration
1. Log in as craft. If the Translation Corruption Detected message 
appears, refer to ‘‘Translation Corruption Detected’’ on page B-5
.
2. Type display memory-configuration and press 
En te r. Check the total 
DRAM field. SIMM field “A” must contain a 16. 
Disassemble the G3vs System
1. Remove any unused 25-pair...