Page 31

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-5 Read This First 
1
Table 1-2. Carriers that use the TN794 NetCon circuit pack
DEFINITY R7.1 or later 
Carrier/Backplane Equipment Notes
SCC Processor Cabinet J58890L-2 List 25 This replaces List 10 
SCC Processor Cabinet 
(Survivable Remote)J58890L-2 List 31 This replaces List 30 
SCC Processor Cabinet (Knock 
Down)J58890L-2 List 52 This replaces List 51 
Backplane for the...

Page 32

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-6 Task Table 
1
Ta s k  Ta b l e
Table 1-3 lists the high-level tasks to perform the upgrades. Refer to the 
appropriate page for instructions for each step.
Table 1-3. Tasks to Upgrade to Release 8si
áTask Description Page
Unpack and Inspect Control Cabinet1-7
Install Control Cabinet1-8
Add Earthquake Protection1-8
Label Existing Cables1-8
Install TDM/LAN Bus...

Page 33

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-7 Upgrade to Release 8si 
1
Upgrade to Release 8si
Unpack and Inspect Control Cabinet 
1. Unpack the J58890L-1 L5 Single-Carrier Control Cabinet and verify  
comcode vintage of the control carrier.
!CAUTION:
Take care to avoid injury while cutting and removing bands.
NOTE:
Verify the vintage of the control carrier and check it against Table 1-2. 
If your carrier is NOT...

Page 34

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-8 Upgrade to Release 8si 
1
Install Control Cabinet
1. Position the control cabinet at the desired location (as close to the Main 
Distribution Frame [MDF] as possible).
!CAUTION:
The cabinet may weigh as much as 130 pounds (58 kg). Use lifting 
precautions to avoid injury.
2. If earthquake protection is not required, install hole plugs (provided with 
cabinet) in the holes...

Page 35

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-9 Upgrade to Release 8si 
1
Figure 1-1. Location of TDM/LAN Bus Terminators
Swing Existing System into Maintenance Position
1. While lifting on the left side of the existing cabinet, allow the left side to 
swing outward and to the right.
Check SPE
Ty p e  status system 1 and press En te r to check the health of the system. 
Disable Scheduled Maintenance and Alarm...

Page 36

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-10 Upgrade to Release 8si 
1
If scheduled maintenance has not begun, set the Start Time field to a 
time after the upgrade is completed. For example, if you start the upgrade 
at 8:00 p.m. and the upgrade takes 90 minutes, set the Start Time field 
to 21:30.
!CAUTION:
If you do not disable Alarm Origination, the system may generate 
alarms, resulting in unnecessary trouble...

Page 37

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-11 Upgrade to Release 8si 
1
Save Translations 
1. Type save translation and press En t e r to write all translation information 
from memory to the original translation flashcard, which takes about 10 
minutes.
When the save translations command is successful, the error code must be 
a zero; otherwise, the translations are not copied. If the translations were 
corrupted,...

Page 38

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-12 Upgrade to Release 8si 
1
7. For each link where the Prot field is set to ISDN, set the Enable field to n 
and press 
En t e r.
8. Type display communication-interface processor-channels and press 
En t e r.
9. For each processor channel where the Application field is set to ISDN, 
record the information in all fields (in case you need to back out of the 
upgrade). 
10....

Page 39

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-13 Upgrade to Release 8si 
1
2. If administered recorded announcements are listed, type save 
announcements 
cabinet carrier slot and press En te r. For example, 
01
D03. This takes about 30 minutes.
NOTE:
For some software loads, type save announcements from cabinet 
carrier slot
. Type help and press En t e r for complete command 
syntax.
Verify Software Version
If...

Page 40

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3vs (w/Intel 386) to R8si 
1-14 Upgrade to Release 8si 
1
Power Down Existing System
!CAUTION:
Powering down the control cabinet causes important system data, such as BCMS data, 
records of queued ACD calls, Automatic Wakeup request, and Do Not Disturb requests, 
to be lost. 
1. Behind the G3vs cabinet, set the circuit breaker to OFF. See Figure 1-2
.
Figure 1-2. Rear of G3vs System Cabinet Figure...