Page 81

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-3 Read this First 
3
Software Upgrade 
Although the translations upgrade automatically to Release 8si, several features 
require special attention because of screen changes or potential naming conflicts 
in the update or upgrade procedure.
Between customer confirmation and the actual update or upgrade, check the 
screens to ensure the translations meet the customer’s...

Page 82

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-4 Read this First 
3
Required Hardware
The equipment in Table 3-1 must be on site before the upgrade begins. To place a 
claim for missing equipment, as part of the Streamlined Implementation process, 
call 1-800-772-5409, or the number provided by your Lucent Technologies 
representative.
Table 3-1. Required Hardware
Quantity
Equipment Description Standard High/Critical...

Page 83

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-5 Task Table 
3
Ta s k  Ta b l e
Table 3-2 provide the high-level tasks to perform the upgrades in this chapter. 
Refer to the appropriate page for instructions for each step. The upgrade 
procedure is similar for both the standard and high or critical reliability system with 
a few exceptions. These exceptions are noted as you go through the steps.
Table 3-2. Tasks to...

Page 84

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-6 Upgrade the Software and Hardware 
3
Upgrade the Software and Hardware
Check  SPE
Ty p e  status system 1 and press En te r to check the health of the system. 
Disable Scheduled Maintenance and Alarm 
Origination to INADS
1. Type change system-parameters maintenance and press En te r to prevent 
scheduled daily maintenance from interfering with the update or upgrade.
2....

Page 85

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-7 Upgrade the Software and Hardware 
3
Disable TTI
NOTE:
Do this step only if the Terminal Translation Initialization (TTI) is disabled 
and you want it enabled.
!CAUTION:
If you do not disable the TTI, the translations can be corrupted.
1. Type change system-parameters features and press En te r. 
2. On the second screen, set the TTI Enable? field to n to de-activate the...

Page 86

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-8 Upgrade the Software and Hardware 
3
NOTE:
The save translation command cannot function if the translation 
corruption message appears. Refer to ‘‘Translation Corruption 
Detected’’ on page B-5 to clear the problem.
NOTE:
This translation card may or not be used in the remainder of the upgrade 
procedure, depending on the outcome of the Remove ISDN Interface Links 
step....

Page 87

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-9 Upgrade the Software and Hardware 
3
13. For each PI extension where the Prot field is set to ISDN:
a. Set the Est Conn field to n.
b. Set the Prot field to bx25.
c. Set the DTE/DCE field to dte.
d. Leave the Identification field blank and press 
En te r.
14. For 
each PI extension where the Prot field was set to ISDN:
a. Type display data-module 
PI Ext number and press...

Page 88

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-10 Upgrade the Software and Hardware 
3
Verify Software Version
If standard reliability:
1. Type list configuration software-version and press 
En t e r. Under the 
UPDATE FILE column, note whether any patches have been applied.
NOTE:
If you restore the system to the old software, you must download 
these patches onto the system.
If high or critical reliability:
1. Type...

Page 89

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-11 Upgrade the Software and Hardware 
3
Remove the Circuit Packs
NOTE:
More detailed information on removing and adding circuit packs is in Chapter 6, 
‘‘Adding or Removing Hardware’’
NOTE:
If this is a duplicated system, remove the circuit packs in both carriers
1. Remove the TN777/B Network Controller (NETCON) circuit pack and place 
it in antistatic packing material....

Page 90

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Upgrading G3s/si (w/Intel 386) to R8si 
3-12 Upgrade the Software and Hardware 
3
Figure 3-1. TN794/TN2400 Network Controller Interface Assembly
3. Install apparatus blanks in any vacated slots.
4. Check the software load number on the TN790B Processor label. Insert the 
appropriate flashcard into the TN794/TN2400 assembly based on the 
following parameters:
nIf the load number is the Release 8 load number, insert...
Start reading Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual