Page 181

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-47 Add IP Interface Assembly 
6
Administration Steps
NOTE:
Refer to the DEFINITY Enterprise Communications Server 
Administration for Network Connectivity for Release 8
 for specific 
information.
1. Log in as craft.
2. Type change node-names and press 
En t e r.
3. On screen 2, type in the node name and IP address for the TN802B.
4. Type change circuit-pack and press 
En t e r.
5....

Page 182

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-48 Add IP Interface Assembly 
6
6. If not, type MEDPRO in the slot just above TN802B slot and press En t e r. 
Changing the one entry automatically changes the entry above it. If it is in 
IP Trunk mode, you get the following error message:
MedPro type requires TN802 with application. Type 
MEDPRO on circuit-packs form.
7. Type change ip-interfaces and press 
En te r. 
8. Type in the...

Page 183

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-49 Add IP Interface Assembly 
6
2. Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press En te r. 
The variable 
nnn.nnn.nnn.nnn is the IP address of the customer’s 
gateway and 
UUCSS is the cabinet, carrier, and slot of the TN802B IP 
Interface.
3. Type ping ip-address 
nnn.nnn.nnn.nnn board UUCSS and press En te r. 
The variable 
nnn.nnn.nnn.nnn is the IP address of another...

Page 184

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-50 Add IP Interface Assembly 
6
nAn analog telephone line reserved for the IP Interface diagnostic modem
nA valid telephone number reserved for the IP Interface diagnostic modem
If non-U.S. customer:
nModem comparable to a U.S. Robotics, Inc. Sportster Model USR 33.6 
EXT.
nA cable from the modem to the TN802B external cable assembly.
We recommend that you protect the cabinet where...

Page 185

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-51 Add IP Interface Assembly 
6
The TN802B external cable assembly is a bundle of cables with an amphenol 
connector at the end of the bundle and various PC-type connectors (VGA, 
Universal Serial Bus [USB], mouse, keyboard, Ethernet, modem, and COM2) at 
the ends of the individual cables. See Figure 6-19
. Look for the label where the 
bundle enters the amphenol connector.
Figure...

Page 186

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-52 Add IP Interface Assembly 
6
Connect the Modem
NOTE:
These instructions are for connecting the U.S. Robotics modem supplied to 
U.S. customers only. If using a different modem, follow the manufacturer’s 
instructions on connecting the modem.
1. Connect the RS232 por t of the modem to the MODEM connector of the 
TN802B external cable assembly. 
NOTE:
Check the labels near the...

Page 187

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-53 Add IP Interface Assembly 
6
Connect the Monitor, Keyboard, and Mouse
NOTE:
Only make these connections if administered locally. Not necessary if 
administered remotely.
You must connect these before inserting the TN802B IP Interface.
1. Attach a VGA monitor to the VGA connector of the TN802B IP Interface 
external cable assembly.
2. Attach the keyboard to the KEYBOARD connector...

Page 188

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-54 Add IP Interface Assembly 
6
Connect the Ethernet
1. Connect the network cable to the ETHERNET connector on the TN802B 
external cable assembly.
NOTE:
You need a CAT5 or better cable for 100-Mbyte operation.
Install the Circuit Pack
!CAUTION:
When adding or replacing any hardware, be sure to ground yourself against 
electrostatic discharge (ESD) by wearing a grounded wrist strap....

Page 189

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-55 Add IP Interface Assembly 
6
Figure 6-21. TN802B IP Interface faceplate
NOTE:
To properly seat the circuit pack, push firmly on the front of the faceplate 
until the latch reaches the bottom rail of the carrier. Then close the latch until 
it is fully engaged.
1. Insert the TN802B IP Interface into the rightmost of the three slots you 
reserved for it (see Figure 6-22
).
When you...

Page 190

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-56 Add IP Interface Assembly 
6
Figure 6-22. J58890MA-1 L30 IP Interface Assembly
Test the Modem
1. Check for dial tone.
2. Contact Lucent Technologies Customer Support and ask a representative 
to dial into your IP Interface server. 
Administer the IP Interface
Adminstration is done either locally or remotely. If administered locally, proceed 
with the following adminstration steps...