Adding or Removing Hardware 
6-107 Installing an Integrated Channel Service Unit (ICSU) Module 
6
!CAUTION:
Do not plug the 120A into any circuit pack other than a TN474F or TN777E 
or later release/vintage. Do not connect the 120A to any interface other than 
a network smart jack.
Be sure the DS1 circuit pack is set for 24-channel operation (1.544 Mbps). 
The 120A does not operate with the 32-channel interface. A...

Page 242

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-108 Installing an Integrated Channel Service Unit (ICSU) Module 
6
nNever use quad cable (untwisted two pair telephone cable) in a DS1 
line.
nAvoid mixing wires of different gauges in a DS1 line.
6. If using external alarm equipment, attach the supplied DW8 cable to the 
120A and the external equipment. The maximum length of this cable 
depends on the alarm equipment.
7. If a TN474F...

Page 243

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-109 Installing a 3150/3170 Channel Service Unit 
6
Installing a 3150/3170 
Channel Service Unit
1. Install the CSU as shown in Figure 6-41. For some installations (such as a 
DS1 converter), use a Y-cable to connect the DEFINITY System to the 
quad cable. Table 6-17
 shows the Y-cable lengths. Be sure to label all 
cables. 
Figure 6-41
 shows a typical connection from the H600-348...

Page 244

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-110 Installing a 3150/3170 Channel Service Unit 
6
Figure 6-41. 3150/3170 Channel Service Unit Connections 
1. H600-348 q uad  c ab le
2. 15-p in male “ D”  c onnec tors (to DTE jac ks on CSU)
3. Channel servic e unit (CSU)
4. H600-307 c ab le (RJ-48C to RJ-48C)5. Network interfac e
6. Smart jac k (if p rovid ed)
7. Cable A
8. Cable B9. Cab le C
10. Cab le D
3150csu RBP 062696...

Page 245

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-111 Installing a 3150/3170 Channel Service Unit 
6
Figure 6-42. DS1 Converter Connections Using Double-Headed cable
1. Port c arrier
2. DS1 c onverter c onnec tor
3. 50-p air female c onnec tor to DEFINITY System
4. 14-Inc h (35.57 c m) “ Y”  c ab le5. 50-Pin Male/50-p in female d ouble-headed   
c onnec tor c ab le
6. Quad c ab le (with 50-pin male c onnec tor) c onnec ts 
to the c...

Page 246

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Adding or Removing Hardware 
6-112 Installing a 3150/3170 Channel Service Unit 
6 

Page 247

Administering and Using ASG 
A-1 Using the ASG Mobile 
A
DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
A
Administering and Using ASG
This appendix provides information on how to administer and use the Access 
Security Gateway (ASG). ASG employs a challenge/response protocol to confirm 
the validity of a user and reduce the opportunity for unauthorized access. ASG 
authentication is imposed for Lucent services logins as indicated below: 
ninit - all types of...

Page 248

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Administering and Using ASG 
A-2 Using the ASG Mobile 
A
5. Use your communications package (for example, DNA, ProComm, or 
TerraNova) to dial the switch you need to contact.
6. Log into your communications package window as either init, inads, or 
craft. Instead of a password prompt, a seven-digit (challenge) number 
appears in the window of your communications package.
7. Move to the ASG Mobile V1.1...

Page 249

Troubleshooting an Upgrade 
B-1 New for Release 8 
B
DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
B
Troubleshooting an Upgrade
This appendix provides information to correct some problems when upgrading a 
system. The information in this appendix is a compilation of the most commonly 
repor ted troubles received by Tier 4 Support at Lucent Technologies. For general 
information on troubleshooting associated with maintenance procedures, see one 
of the...

Page 250

DEFINITY ECS Release 8.2
Upgrades and Additions for R8.2si  555-233-122  Issue 1
April 2000
Troubleshooting an Upgrade 
B-2 New for Release 8 
B
ATM Expansion Interface (ATM-EI)
The ATM-EI maintenance object covers the ATM circuit pack administered as an 
ATM-Port Network Connectivity (PNC) Expansion Interface (ATM-EI). The ATM-EI 
provides PNC between a DEFINTY PPN and all the EPNs through the ATM 
switch.
The circuit packs listed below are ATM-EI boards 
if they are administered to serve 
the ATM Port...