Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 151
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-45 Administer Fiber Links (Release 8r Only) 3 NOTE: When you ad minister DS1 Converter TN1654 c irc uit p ac ks, d ifferent field s display. For field d efinitions of the field s d isp layed on p ag e 3 of the Fib er Link Ad ministration form, refer b ac k to the p revious sec tion. DS1 Converter Complex Administration for T1 TN1654 Circuit Packs. Screen...
Page 152
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-46 Administer Fiber Links (Release 8r Only) 3 estab lishes a link on a T1/E1 fac ility. The initial id le c od e used b y the TN1654 is overwritten b y the c enter stag e switc h to an “ all ones” p attern onc e framing is estab lished on that T1/E1 fac ility. nFraming Mode — For TN1654 with 1.544 Mb p s Bit Rate, this is a d isp lay-only field ....
Page 153
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-47 Administer Fiber Links (Release 8r Only) 3 nBit Rate — Disp lays when the DS1 Converter c irc uit pac k is TN1654. Enter either 1.544 for d omestic T1 op eration or 2.048 for international E1 op eration. NOTE: Sinc e one b it rate ap p lies for all fac ilities within the same DS1 Converter c omp lex, Bit Rate d isp lays only und er Fac ility A. To...
Page 154
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-48 Reboot High Reliability System 3 Reboot High Reliability System 1. Type reset system 4 and p ress En t e r. 2. When the login: prompt appears, login as craft. 3. Ab out eig ht minutes after b ooting and at the Command: p rompt, typ e status spe and press En t e r. 4. Verify that handshake, shadowing, and refreshed are all shown to b e either yes...
Page 155
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-49 Save Translations 3 Save Translations Save Translations (Release 8si) For stand ard reliab ility systems, 1 translation c ard p lus 1 b ac kup is required . For high or c ritic al reliab ility systems, 2 translation c ard s p lus 2 b ac kup s are req uired . !CAUTION: Do not attemp t to save translations on the orang e-lab eled , 10 MB memory c ard ....
Page 156
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-50 Installation Completion 3 Installation Completion 1. The system must now b e tested for p rop er op eration. See Chap ter 4, ‘‘Te s t the System’’. 2. After c omp letion of the system tests, install the telep hones and other eq uip ment. See Chapter 5, ‘‘ Install and Wire Telep hones and Other Eq uip ment’’. 3. Ad minister the system b y ad d ing...
Page 157
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-51 DEFINITY AUDIX Power Procedures 3 nIf the AUDIX remained in the c ab inet b ut p ower was removed from the c ab inet: 1. Power up the c ab inet. The AUDIX reb oots automatic ally. 2. Check for AUDIX System errors. nIf the AUDIX remained in the c ab inet and the c ab inet was not p owered down: 1. At the AUDIX c onsole, hold the crtl key and enter...
Page 158
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-52 DEFINITY AUDIX Power Procedures 3
Page 159
Test the System 4-1 4 DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 4 Test the System The following tests p rovid e verific ation of the TDM b us c ables and terminators, and fib er op tic inter-c ab inet c ab les. If a FAIL result c od e is seen or other p rob lems are ind ic ated , c hec k these c ab les. If p rob lems c ontinue, refer to DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8r or DEFINITY Enterp...
Page 160
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Test the System 4-2 Check System Status for Each Cabinet 4 Check System Status for Each Cabinet 1. Verify the terminal sc reen d isp lays: Command: 2. Type status cabinet and press En t e r. 3. Verify the sc reen d isp lays system status sc reens similar to Sc re e n 4 - 1 : Screen 4-1. Example System Status Screen for Cabinet 1 Check Circuit Pack Configuration 1. Verify the sc reen d isp...