Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 191
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-17 Connect External Alarm Indicators 5 Connect External Alarm Indicators Alarm Input Alarms can be generated on adjunct equipment, sent to the DEFINITY System, and recorded and reported as “external alarms.” A typical major alarm input is from an Uninterruptible Power Supply (UPS). 1. Connec t 1 major and 1 minor alarm inp ut p air to the...
Page 192
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-18 Connect Power Distribution Unit External Alarm Wires 5 Emergency Transfer and Auxiliary Power Connect emergency transfer power and auxiliary power as shown in Ta b l e 5 - 7. Auxiliary power includes power to an attendant console or adjunct device. Connect Power Distribution Unit External Alarm Wires The external alarm plug should already...
Page 193
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-19 Connect Power Distribution Unit External Alarm Wires 5 7 Not Used 33 RFA2 + Rec tifier Failure (p ositive) 8 RFA2 - Rec tifier Failure (neg ative) 34 ACF2 + AC Failure (p ositive) 9 ACF2 - AC Failure (neg ative) 35 BIF2 + Battery Interfac e Failure (p ositive) 10 BIF2 - Battery Interfac e Failure (neg ative) 36 BOD2 + Battery On Disc harg e (p...
Page 194
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-20 Remote Network Interface 5 NOTE: RS-232 alarms (RXD, DTR, DSR, TXD, RS-232 GRD, and RTS) are not sup p orted on the BU3200A Battery Interfac e Unit. 1. Choose an alarm to c onnec t (suc h as Battery Interfac e Failure). 2. Choose the p ort c irc uit p ac k to use and its c arrier and slot numb er (from Tab le 5-3 ). For example TN2183...
Page 195
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-21 TN1654 DS1 Converter (R8r Only) 5 the TN1648 System Access/Maintenance (SYSAM) circuit pack through the remote network interface terminals at the trunk/auxiliary Main Distribution Frame (MDF). Figure 5-10 shows a typical network interface trunk installation. 1. Determine the network interfac e trunk ap pearanc e at the g reen trunk/auxiliary...
Page 196
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-22 TN1654 DS1 Converter (R8r Only) 5 Set Circuit Pack Switches The configuration switches on the TN1654 must be set before the circuit pack is installed. The TN1654 can be configured for either T1 or E1 operation. All 4 facilities on the circuit pack are configured as a group. It is not possible to have T1 and E1 facilities supported on the same...
Page 197
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-23 TN1654 DS1 Converter (R8r Only) 5 . 1. Set the c onfig uration switc hes on the TN1654 as req uired p er site. 2. Set Switc h 6 d own (d isab led ). Switc h 6 may not b e p resent (or ac tive) on all TN1654 DS1 Converter c irc uit p ac ks. 3. Set Switc h 1 up for T1 fac ilities. All sub seq uent fac ility switc h setting s (Switc hes 2-5)...
Page 198
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-24 TN1654 DS1 Converter (R8r Only) 5 Install the Circuit Pack and Cabling (T1 Only) The following installation instructions are provided as examples only. NOTE: Be sure to lab el all of the c ab les as they are installed . Port Carrier 1. Install the TN1654 c irc uit p ac k in any slot in a Port Carrier c lose to a TN570C Exp ansion Interfac e c...
Page 199
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-25 TN1654 DS1 Converter (R8r Only) 5 Figure 5-12. DS1 Converter Connections — Part 1 Switch Node Carrier You can install up to 2 TN1654 circuit packs in a Switch Node Carrier. 1. Install the TN1654 c irc uit p ac k in either slot 1 or 21 of the Switc h Nod e Carrier c lose to a TN573B SNI c irc uit pac k. !CAUTION: Install the TN1654 c irc uit p...
Page 200
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-26 TN1654 DS1 Converter (R8r Only) 5 !CAUTION: The Y c ab le used with the TN1654 c irc uit p ac k is d ifferent than the Y c ab le used with the TN574 c irc uit p ac k. These c ab les are NOT interc hangeab le. 3. Connec t an H600-348 Quad c able to the other sid e of the Y c able. 4. Skip to ‘‘ Channel Servic e Unit Cab ling’’. Port Carrier...