Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual
Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 231
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-57 1151A1 Power Supply 5 !CAUTION: The p ower sup p ly c an be used only with telec ommunic ations equip ment, indoors, and in a c ontrolled environment. The power supply has a single output of -48 VDC, 0.4 Amps, and can operate from either a 120 VAC 60 Hz power source (105 to 129 VAC) or a 220/230/240 VAC 50 Hz power source (198 to 264 VAC)....
Page 232
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-58 BRI Terminating Resistor 5 BRI Terminating Resistor The resistors balance the cable plant between the receiver and the transmitter on the interface. When using the TN2198 ISDN-BRI 2-Wire U Interface circuit pack, an NT1 is required. A terminating resistor is always required near the terminal when the BRI S-type interface circuit pack (TN556...
Page 233
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-59 BRI Terminating Resistor 5 Figure 5-26. 8-Wide Terminating Resistor Adapter (440A4) Closet Mounted (110RA1-12) The 110RA1-12 terminating resistor block is designed to mount in the telecommunications wire closet. It consists of twelve 2-pair circuits and provides the 100 Ohm termination used for ISDN-BRI circuits. Figure 5-27 shows the wiring...
Page 234
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-60 BRI Terminating Resistor 5 Figure 5-27. Terminating Resistor Block (110RA1-12) Figure 5-28 shows the wiring connections for the 110RA1-12 terminal block. The TN556 Basic Rate Interface (BRI) switch port is terminated to bottom row C. Figure Notes 1. Circuit 1 2. Circ uit 12 3.Outp ut Row “A” 4. Output Row “B”5. Inp ut Row “ C” 6. Only First...
Page 235
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-61 BRI Terminating Resistor 5 Figure 5-28. Typical Installation of Terminating Resistor Block (110RA1-12) For point-to-point wiring, the top row connects to the blue station field. The pair connects from the 110RA1-12 to the standard 4-pair circuit. Pair 1 from the 110RA1-12 connects to Pair 1 of the station field, and Pair 2 connects to Pair 3...
Page 236
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-62 Multi-point Adapters 5 Multi-point Adapters Multi-point Adapters are used to provide signal fanout of the T-interface. Fanout can be performed at the work station by the BR851-B or the 367A. These adapters support more than one ISDN terminal per horizontal 4-pair D-inside wire (DIW). To support multiple horizontal runs, perform fanout in the...
Page 237
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-63 Multi-point Adapters 5 367A Adapter The 367A adapter provides fanout. See Figure 5-30. It can provide inputs to up to 7 terminals. The 367A is an 8-conductor adapter and can be is used at the work location for bridging 3 to 7 terminals. Figure 5-30. Wiring Diagram of 367A Basic Multipoint Installation Distances Figure 5-31 provides cabling...
Page 238
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-64 Multi-point Adapters 5 Figure 5-31. Basic Multi-point with 1 Work Location Figure Notes 1. S-Interfac e Sourc e (TN556) 2. Terminating Resistor 3. Satellite Closet 4. Maximum Distanc e from S-Interfac e Sourc e to Work Loc ation (1600 Feet) (488 m) 5. Maximum Distance From Satellite Closet to Work Loc ation (250 Feet) (76 m)6. System Cab...
Page 239
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-65 Add Circuit Packs 5 Add Circuit Packs When installing additional features or equipment, it may be necessary to install additional port circuit packs. See Table 5-19 for a list of circuit packs. This is a general procedure to use when adding features or equipment that require adding circuit packs. !CAUTION: The c ontrol c irc uit p ac ks with...
Page 240
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-66 List of Circuit Packs 5 Table 5-19. Circuit Packs and Circuit Modules Apparatus Code Name Type 631DA1 AC Power Unit (MCC) (+ 5V, 60A) Power 631DB1 AC Power Unit (MCC) (-48V/-5V,8A) Power 644A1 DC Power Unit (MCC) (+ 5V, 60A) Power 645B1 DC Power Unit (MCC) (-48V, 8A) Power 649A DC Power Unit (MCC) (-5, + 5, -48V) Power 982LSCurrent Limiter...