Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 271
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-97 Add ISDN — PRI 5 Add ISDN — PRI North American 1. Use a TN767E (or later) DS1 or a TN464F DS1/E1 c irc uit p ac k for a sig naling link and up to 23 ISDN — PRI Trunk Group members. 2. Install a TN768, TN780, or TN2182B Tone-Cloc k c irc uit p ac k to p rovid e sync hronization for the DS1 c irc uit p ac k. If a TN464 is used, packet bus...
Page 272
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-98 Add ISDN — PRI 5 Add Circuit Packs 1. Determine port assig nment of c irc uit p ac ks to be ad d ed . 2. Install the DS1 Interfac e c irc uit p ac k in the assig ned c arrier slot. 3. Install a TN748B (or later) (or the international TN420B/C) Tone Detec tor circuit pack if required. Install Cables 1. Install c ab les from c ab inet to MDF as...
Page 273
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-99 Add Packet Bus Support 5 Add Packet Bus Support NOTE: This p roc ed ure is valid for G3si systems only. It d oes not ap p ly to G3r systems. Standard Reliability Service Interruption 1. If packet bus support for G3si must be added and TN750s must be installed as part of that support, then adding Packet Bas Support requires a servic e...
Page 274
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-100 Add Packet Bus Support 5 Install Circuit Packs 1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-23. Power Up System 1. At the EPN, set the main c irc uit b reaker to ON. 2. At the PPN, set the main c irc uit b reaker to ON. 3. The system p erforms a level 4 reb oot, load ing the system translations from the translation c ard s....
Page 275
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-101 Add Packet Bus Support 5 Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the reg ional Customer Software Ad ministration to c omp lete the step s in the shad ed b ox. See ‘‘ Where to Call for Tec hnic al Sup p ort’’ on page -xvii for telep hone numb ers....
Page 276
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-102 Add Packet Bus Support 5 Disable Alarm Origination 1. Type change system-parameters maintenance and press En t e r. 2. Set the Alarm Origination Activated to OSS Numbers field to n . !CAUTION: If you d o not d isab le Alarm Orig ination, the system may g enerate alarms, resulting in unnec essary troub le tic kets. 3. For some releases of...
Page 277
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-103 Add Packet Bus Support 5 Install Circuit Packs 1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-24. Power Up System 1. At the EPN, set the main c irc uit b reaker to ON. 2. At the PPN, set the main c irc uit b reaker to ON. 3. The system p erforms a level 4 reb oot, load ing the system translations from the translation c ard s....
Page 278
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-104 Add Packet Bus Support 5 3. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e restore announcements and press En t e r. 4. Up d ate b ac kup c ard s, if nec essary. Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the reg ional...
Page 279
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-105 Add CallVisor ASAI 5 Add CallVisor ASAI Service Interruption 1. If ad d ing the pac ket b us sup p ort and TN570s must b e installed as part of that sup p ort, then ad d ing CallVisor ASAI req uires a servic e interrup tion. Notify the c ustomer in ad vanc e as to when the ad d ition will take p lac e. See ‘‘ Add Packet Bus Support’’ on...
Page 280
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-106 Add ISDN—BRI 5 The TN748B (or later) or TN744/C/D Call Classifier c irc uit p ac k is req uired . The TN744 is req uired for those c ustomers who d esire switc h c all c lassific ation. A vac ant p ort is req uired on a TN556/B ISDN—BRI circuit pack. Install Cables 1. Install c ab les from c ab inet to the MDF as req uired . Enter Added...