Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 201
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-27 TN1654 DS1 Converter (R8r Only) 5 Figure 5-13. DS1 Converter Connections for T1 Service — Part 2 1. Connec t the H600-348 Quad Cab le to the DTE jac ks on eac h of the 4 CSUs. NOTE: You may need an ad ap ter c ab le to c onnec t the H600-348 c ab le to the CSU (see Tab le 5-12 ) Figure Notes 1. H600-348 Quad Cable 2. 15-Pin Male D Connec...
Page 202
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-28 TN1654 DS1 Converter (R8r Only) 5 2. Connec t one end of the H600-383 c able to the network jac k on the CSU and the other end to the smart jac k. Connection to the remote-located system is the same as that shown in Figure 5-12 and Figure 5-13. Table 5-13 shows the Y cable lengths and associated comcode numbers. NOTE: The d istinc tion b...
Page 203
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-29 TN1654 DS1 Converter (R8r Only) 5 Customer-provided CSU Cabling For certain markets with 120-ohm E1 service, the service provider provides a unit comparable to the CSU. Figure 5-14 shows a typical connection from the H600-348 Quad Cable customer-provided network-interface equipment. 1. Connec t the H600-348 Quad Cab le to the DTE jac ks on...
Page 204
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-30 TN1654 DS1 Converter (R8r Only) 5 75-ohm E1 Interface Cabling For certain markets with 75-ohm E1 service, the DS1 converter requires an adapter to convert the 120 ohms to 75 ohms. Figure 5-15 shows the 127A BALUN coaxial adapter. NOTE: Althoug h the TN1654 DS1 c onverter sup p orts 75 ohms, use the 127A BALUN to c onvert the 120 ohms to 75...
Page 205
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-31 TN1654 DS1 Converter (R8r Only) 5 Figure 5-16 shows a typical connection. Figure 5-16. DS1 Converter Connections for E1 75-ohm Service — Part 2 Mounting Procedure 1. Mount the 127A vertic ally near the main distrib ution frame (MDF). The 127A c ase has tab s for sc rew-mounting and c utouts for snap -mounting the unit in a 89-typ e...
Page 206
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-32 Off-Premises Station Wiring 5 5. Insert the other end into the sc rew-c onnec tion in the end of the 127A and sec ure. See Fig ure 5-15 . NOTE: In Norway, Swed en, Denmark, and Finland , the 127A c an b e used only with MCCs or DC-p owered SCCs. 6. Connec t the H600-348 Quad Cab le to the 4 DB-15 c onnec tors p rovid ed on the 127A ad...
Page 207
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-33 Off-Premises or Out-of-Building Stations 5 Analog Off-Premises Stations Figure 5-17 shows the connections for 1 to 8 off-premises analog telephones. Only analog telephones connected to TN742, TN746B, TN2183, or TN769 Analog Line circuit packs can be installed out-of-building. The maximum distance from the system cabinet to the out-of-building...
Page 208
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-34 Off-Premises or Out-of-Building Stations 5 Figure 5-18 shows the connections for up to 24 off-premises analog telephones. Concentrations of analog line pairs are used at both buildings to minimize the off-premises wiring required. At the MDF, connect jumpers between 1 row/connecting block in the white field and up to 3 rows/connecting blocks...
Page 209
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-35 Off-Premises or Out-of-Building Stations 5 Carbon block, or equivalent protection is required at both building entrances. Also sneak current protection is required. Protection can be provided by a 4-type protector or a 3-type protector plus a separate sneak current protector. The 4-type protector is equipped with a heat coil. The 4-type...
Page 210
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-36 Off-Premises or Out-of-Building Stations 5 Digital Out-of-Building Voice Terminals Protection is required at both building entrances for digital out-of-building voice terminals. There are 2 different types of protectors that can be used to protect digital voice terminals and digital line circuit packs in an out-of-building environment. The 2...