Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 111
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-5 Access the System 3 Connecting a PC You c an c onnec t your PC or lap top to the DEFINITY ECS R8si/R8c si/R8r either d irec tly (50 ft [ 15 m] or less) or remotely throug h a d ata mod ule or a mod em. Connecting directly to the DEFINITY ECS You c an c onnec t d irec tly from the PC if it is 50 ft (15 m) or less from the DEFINITY ECS. 1. Connec t the...
Page 112
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-6 Access the System 3 Connecting remotely to the DEFINITY ECS To c onnec t remotely to the system, you need one of the following p iec es of hard ware: nConnec ting throug h a data mod ule nConnec ting b y analog mod em to INADS p ort Connecting through a data module If more than 50 ft (15 m) from the DEFINITY ECS, you c an c onnec t the PC throug h a...
Page 113
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-7 Access the System 3 NOTE: With a 7400A or 7400B+ data mod ule, use a 4-wire d ig ital line c irc uit p ac k. With the 8400B+ d ata mod ule, use a 2-wire d igital line c irc uit p ac k. In p lac e of a 7400B+ d ata mod ule, you c an use a 7400A d ata mod ule. If you do, set the 7400A to DCE Mod e. 2. Wire the d ig ital line c irc uit p ac k to the wall...
Page 114
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-8 Access the System 3 Testing Hardware Connections In the following tab le, find your d ata mod ule and follow the instruc tions for testing and troub leshooting it. . Setting the Data Module Operating Mode 1. Connec t an RS-232 c ab le from the DSA/DNA c omp uter to the d ata mod ule. If you are using an 8400B+ , c onnec t the DSA/DNA c omp uter to...
Page 115
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-9 Access the System 3 Setting the 7400B+ Options 1. Set the DIP switc hes for the 7400B+ using Tab le 3-3. The DIP switc hes are loc ated insid e the unit. To ac c ess them a. Remove the p ower c ord from the unit. b . Remove the c over from the top rear of the unit. c . Set the d ip switc hes. d . Rep lac e the c over. e. Connect the power c ord.The...
Page 116
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-10 Access the System 3 1. Connec t the eq uip ment as shown in Fi g u re 3 - 5. Figure 3-5. A typical remote connection through a modem to access a remote DEFINITY ECS Follow these step s to c onnec t to the DEFINITY ECS through a mod em. 1. Connec t the c omp uter to the mod em. 2. Connec t an analog telephone line to the left most analog -line p ort on...
Page 117
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-11 Access the System 3 4. Plug the mod em into an AC p ower outlet. 5. Turn on the modem. 6. Set the following p ort setting s: Table 3-4. U.S. Robotics Modem Dip Switch Settings Dip Switch Setting Description 1UP DOWNData Terminal Read y normal Data Terminal Ready override 2UP DOWNVe r b a l r e s u lt c o d e s Numeric result codes 3UP DOWNSuppress...
Page 118
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-12 Activate the System 3 Activate the System Instruc tions are p rovid ed to ac tivate Release 8 and later systems. To ac tivate a G3V4 and earlier system, refer to DEFINITY Communic ations System Generic 3 Installation and Test. NOTE: To p revent unnec essary troub le tic kets, d o not enab le the system alarms (Alarm Orig ination feature) until all...
Page 119
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-13 Activate the System 3 Figure 3-6. TN2211 Optical Drive NOTE: Make sure the formatted removab le med ia is not write-p rotec ted (see Fig ure 3-7 ) b efore plac ing it into the op tic al d rive. Figure 3-7. Make sure the disk is not write protected Figure Notes 1. Not write protec ted 2. Write p rotec ted Red Green Yellow fpdf2211 KLC 010600TN2211 OPTICAL...
Page 120
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-14 Activate the System 3 Power Up the System AC-Powered System 1. Set the c irc uit breakers on the AC p ower p anel to ON. If the system is hig h or c ritic al reliab ility, p ower-up the EPN c ab inet first, then the PPN c ab inet. Always p ower up the PPN c ab inet last. 2. Set the c ab inet c irc uit breakers to ON. This starts the system initialization...