Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 91

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-35 Station Circuit Distribution from Equipment Room 
2
The 4-p air station c ab les c an b e run d irec tly from the eq uip ment room to the 
information outlets if 4-p air terminal b loc ks are used  in the d istrib ution field . See 
Figure 2-20
. The station c ables must b e field -terminated  on the 110-typ e terminal 
blocks.
Figure 2-20. 4-Pair Run to...

Page 92

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-36 Station Circuit Distribution from Equipment Room 
2
If 110-type terminal b loc ks are used  with a mod ular p lug -end ed  station c ab le, an 
ad ap ter c an be c onnec ted  d irec tly to the 110-typ e terminal b loc k c onnec tors. 
See Fig ure 2-21
.
Figure 2-21. 4-Pair Run to Equipment Room or Satellite Location Figure Notes:
1. Part of MDF
2. 3-Pair...

Page 93

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-37 Station Circuit Distribution from Equipment Room 
2
3-Pair to 4-Pair Station Circuit Distribution
Fi g u re  2 - 2 2 shows the 3-p air c irc uit distrib ution from an eq uipment room MDF to 
a satellite loc ation using  110-typ e hard ware. Four-p air c irc uits are d istrib uted  
from the satellite loc ation to the information outlets.
Figure 2-22. 3-Pair...

Page 94

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-38 Station Circuit Distribution from Equipment Room 
2
Three-p air c irc uits c an also b e run direc tly from the eq uip ment room MDF to a 
356A ad ap ter as shown in Fig ure 2-23
. Four-p air station c ab les c onnec t the 
ad ap ter to the information outlets. Four-p air station c ables c an b e run d irec tly 
from a satellite loc ation to the information...

Page 95

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-39 Layout 
2
Layout
Locate Information Outlets
The customer or marketing representative must provide floor plans showing the 
information outlet loc ations and  typ es (flush- or surfac e-mounted ) req uired . The 
floor plans must also show a c omplete overview of all c onduit and cabling 
fac ilities in the b uild ing.
Locate Satellites and Sites
Use the...

Page 96

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-40 Layout 
2
Sizing 25-Pair and Multiple 25-Pair Station 
Cables
Use the sc ale of the floor p lan to d etermine the ap p roximate leng th of eac h 
25-p air station c ab le. The c ables must b e selec ted and  p rop erly sized  to make 
maximum use of the hard ware at the equip ment room or satellite loc ation.
Use 25-p air B25A c ab les to c onnec t ad ap ters...

Page 97

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-41 Voice and Data Terminals 
2
Voice and Data Terminals
The system c an c onnec t to all DTE terminals and  have RS-232 (or EIA-232) or 
DCP interfac es. Ta b l e  2 - 4
 lists some of the terminals that c an c onnec t to the 
system. Contac t your Luc ent Tec hnolog ies rep resentative for more information.
Table 2-4. Voice and Data Terminals
Station Type Type...

Page 98

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-42 Voice and Data Terminals 
2
Dig ital set — 7401D/7401+
Dig ital set — 7403D
Dig ital set — 7404D
Dig ital set — 7404D w/d isp lay
Dig ital set — 7405D
Dig ital set — 7405D w/d isp lay
Dig ital set — 7405D w/c ov
Dig ital set — 7406D
Dig ital set — 7406D w/d isp lay
Dig ital set — 7406+
Dig ital set — 7406+  w/d isp lay
Dig ital set — 7407D 
Dig ital set —...

Page 99

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-43 Voice and Data Terminals 
2
The following notes ap p ly to the b utton and  d ata mod ule rec ord s in Ta b l e  2 - 4:
nAny DCP p hone (exc ep t 6400- and  8400-series) c an ad d  a 7400B, 
req uiring 1 d ata module rec ord .
nA d ata mod ule c an b e ad d ed  to a 7403D or 7405D, req uiring  1 d ata 
mod ule rec ord .
nA d ata mod ule (ADM-T) c an b e ad...

Page 100

DEFINITY ECS Release 8.2 Installation and Test
for Multi-Carrier Cabinets  555-233-114  Issue 1
April 2000
Install Telecommunications Cabling 
2-44 Label the Main Distribution Frame 
2
Administration Terminals
Tab le 2-5 lists the ad ministration terminals that c an b e c onnec ted  to the system.
NOTE:
The 715 BCS (406803148 and 406803155), has a 6-p in mini-DIN keyb oard 
c onnec tor. The 2900/715 BCS (4073113881 and  407313899), has a 6-p in 
RJ-11 keyb oard  jac k loc ated  on the sid e of the...