Page 111

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-19 Remote Machine Test 
6
Tab le 6-12 shows test results for normal mod e 1 and  3 c alls.
Table 6-12. Test Results for Normal Mode 1 and 3 Calls
Most Recent Test 
Result
(Last Step that 
Completed)Most Recent Test Result 
(Failure) Possible Problem Corrective Action
R Seizing  Pass F Dialing-Denied Numb er of the Remote 
AUDIX Networking  Port 
incorrectChec k the numb er in the d ial 
string .
R Seizing  Pass F...

Page 112

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-20 Remote Machine Test 
6
Tab le 6-13 shows test machine results.
Table 6-13. Test Machine Results 
Test Name Test Result Repair Action
Test c onnec tion P Test Done-Pass na (Test d one suc c essfully)
R p ort b usy, waiting Use other port or c ontinue waiting.
R Starting Starting  the test
A p ort is OOS-F Fix network port alarm, try ag ain.
A p ort is OOS-R Fix MF-BD or software alarms, try ag ain.
A p ort is OOS-C...

Page 113

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-21 Remote Machine Test 
6
Test c onnec tion R Starting  DSPLike is says, “starting  DSP”
R Dialing xxx Eac h d ial stag e is disp layed  as it is sent to 
the mod em.
R Ok Disp lays if the modem ac c epts the init 
string .
R Send ing  BREAK Send ing break to remote data mod ule 
p rior to last d ial stage
R Connec ted Loc al mod em is c onnec ted to remote 
modem.
R Ring ing Remote AUDIX or mod em is ring ing .
R...

Page 114

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-22 Remote Machine Test 
6 

Page 115

Filesystems 
7-1  
7
DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
7
Filesystems
Minor and  major alarms ag ainst the filesystems g enerally req uire system 
initialization. If a serious p rob lem oc c urs d uring  normal system op eration, an 
alarm is raised  and  no c orrec tive ac tion is taken until the system is reb ooted . The 
alarm is retired  b y the reb oot. 
If the filesystem c annot b e rep aired during  initialization, more drastic  rep air 
ac tion will b e req uired ,...

Page 116

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Filesystems 
7-2 Customer Storage Problems 
7
Customer Storage Problems
Re f e r  t o  Table 7-1, Storag e Filesystem Alarms and  Rep air Proc ed ures, for a list of 
alarms and  repair p roc ed ures ad d ressed  to the storag e filesystem. Perform 
d ashed  rep air ac tions one at a time until the p rob lem is solved . Alarms ap p ear in 
the 
DISPLAY ALARMS sc reen und er the resourc e typ e:
STORAGE
Table 7-1. Storage Filesystem Alarms...

Page 117

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Filesystems 
7-3 Customer Storage Problems 
7
Tab le 7-2, Storag e Filesystem Errors, lists the errors log g ed  in the D I SPL AY ERRO RS 
sc reen. If these errors exc eed a c ertain threshold , they may g enerate the ab ove 
alarms. Note that pseud onyms of listed  error resourc es may app ear in the error 
log; these 
hidden resourc es are listed in parenthesis with their related resourc es.
 
4
Ac tive announc ement 
set is inac c...

Page 118

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Filesystems 
7-4 Master Data Problems 
7
Master Data Problems
Refer to Ta b l e  7 - 3, Master Data Filesystem Faults and  Rep air Proc ed ures, for a 
list of alarms and  rep air p roc ed ures add ressed  to the Master Data filesystem. 
Alarms ap p ear in the 
D I SPL AY A L A RM S sc reen under the resourc e typ e:
The system must b e b rought to the OA&M state b efore rep air on this filesystem 
can begin. 
Tab le 7-4, Master Data...

Page 119

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Filesystems 
7-5 Master Data Problems 
7
Table 7-4. Master Data Filesystem Errors
Error
ResourceError
Code DescriptionFault
ResourceFault
Code
M_DATA 81
Period ic  MP 34 failed (c hec k file thresholds)M_DATA 1
FILESYSTEM 132
System FS d river — Filesystem c orrup ted  M_DATA 2
FILESYSTEM 133
System FS d river — no free spac e M_DATA 0
FILESYSTEM 134
Filesystem is out of free i-nodes M_DATA 3
FILESYSTEM 135
System FS d river — internal s/w...

Page 120

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Filesystems 
7-6 System Data Problems 
7
System Data Problems
Refer to Tab le 7-5, System Data Faults and  Rep air Proc ed ures, for a list of alarms 
and  rep air proc ed ures ad d ressed  to the System Data filesystem. Alarms ap p ear 
in the 
DISPLAY ALARMS sc reen und er the resourc e typ e:
Exc ep t for fault c od e 4, the system must b e broug ht to the OA&M state before 
repair can begin.
S_DATA
Table 7-5. System Data Faults and...
Start reading Lucent Technologies Definity Audix System Release 4.0 Maintenance Guide