Page 151
Audits, Shutdown Codes 9-1 Audits 9 DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 9 Audits, Shutdown Codes Audits The aud its that automatic ally keep the DEFINITY AUDIX System sane, c onsistent, and c lean are alarmed ac c ord ing to whether they are p erformed nig htly or weekly. Table 9-1, Pe r io d i c Au d i t s, lists the typ es of aud its that run d uring system op eration. Most of the aud its c an also b e p erformed on a demand b asis as indicated below and...
Page 152
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Audits, Shutdown Codes 9-2 Audits 9 When the system is op erating normally, d emand aud its need not be run. Only the RSC would run an aud it should the system c rash, or to ob serve p rob lems c onc erning voic e spac e, filesystem threshold s, remote messag e add ressing , sub sc rib er log in diffic ulties, and so forth. Note in Ta b l e 9 - 2 that it would b e p ermissib le for the c ustomer to run Selec ted Aud its in an...
Page 153
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Audits, Shutdown Codes 9-3 Audits 9 4 Switc h translation audit failedMINORNIGHT_AUD or WEEKLY _AUDResolved if the next nightly switc h translation aud it passes. Run audit switc h translations. 5 MaiIb ox aud it failedMINORNIGHT _AUD or WEEKLY_AUD— Resolved if the next nig htly aud it p asses — Run aud it mailboxes. — If the alarm remains, alert the RSC. 6 Network d ata audit failedMINORNIGHT_AUD or WEEKLY_ AUD— Resolved if...
Page 154
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Audits, Shutdown Codes 9-4 Audits 9 Tab le 9-3, Audit Errors, lists the errors that may trig ger the ab ove alarms. Table 9-3. Audit Errors Error ResourceError Code DescriptionFault ResourceFault Code NIGHT_AUD 81 Sc hed uled MP 39 failed (g et names d irec tory from switc h)AUDIT 2 NIGHT_AUD 81 Sc hed uled MP 40 failed (aud it messag e waiting ind ic ators)AUDIT 3 NIGHT_AUD 81 Sc hed uled MP 41 failed (aud it d elivery queues)AUDIT...
Page 155
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Audits, Shutdown Codes 9-5 Audits 9 Tab le 9-4, Demand Aud it Test Results, lists d emand aud its, ind ivid ual tests that are p erformed, and any ac tions that need to b e p erformed . NOTE: A d emand aud it and the TEST MO func tion c annot b e run at the same time. Table 9-4. Demand Audit Test Results Te s t N a m eTe s t Result (Passed) Test Result (Failed)Test Result (Aborted) Action Aud it Mailb oxes P Passed F Fa il e...
Page 156
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Audits, Shutdown Codes 9-6 Shutdown Codes 9 Shutdown Codes Fault c od es are g enerated from the DEFINITY AUDIX System flashware whenever the system shuts d own and goes into firmware mod e. These c odes ap p ear automatic ally on the loc al and/or remote maintenanc e terminal. Whenever the DEFINITY AUDIX System reinitializes, the c od es will ap p ear in the event log . Ta b l e 9 - 5, System Shutd own Cod es, lists these faults...
Page 157
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Audits, Shutdown Codes 9-7 Shutdown Codes 9 f02a Shutdown from software Major Look at the old shutd own reason on the maintenanc e terminal. The only c odes need ing rep air ac tions are: d a01 — Restore from generic . d 7xx — Failed installation. Attemp t reinstallation. f02b Software system error Major Contac t Luc ent servic es f050 15 c onsec utive disk failures or system failed to b oot from d iskMAJOR 1. Chec k b oard — If...
Page 158
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Audits, Shutdown Codes 9-8 Shutdown Codes 9 f054 Bad disk drive or SCSI c onnec tionMAJOR— Chec k the SCSI c abling . — Rep lac e the hard disk, SCSI c ab le, and the TN568, in that ord er. f055 Bad load er/p artition or b oot c ontrolMAJOR Reinstall from g eneric MO disk and restore b ac kups. f058 Cannot boot from a write- p rotec ted disk.None — Chec k the SCSI c abling to the hard d isk. — Rep lac e the hard d isk. f059...
Page 159
Utilities, On-Site Diagnosis 10-1 Standalone Utilities 10 DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 10 Utilities, On-Site Diagnosis This c hapter d esc rib es the utilities p rovid ed for the DEFINITY AUDIX System. Note that most of the utility p roc ed ures should b e d one b y the on-site tec hnic ian and not attemp ted b y the c ustomer. Standalone Utilities Stored on the g eneric MO d isk, the Stand alone Utilities are used when the system will not b oot to the...
Page 160
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Utilities, On-Site Diagnosis 10-2 Standalone Utilities 10 Table 10-1. Standalone Utilities Options Option Description Exit Exits from the utilities b ac k to firmware mode. Initialize Disk (5 sec ond s) nCreates a valid d isk boot bloc k and writes it to the d isk nBuild s a d efault p artition map and writes it to the d isk Mod ify Partition Map (5 sec ond s) This selec tion bring s up a sec ond level of menu op tions. These...