Page 131

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-9  
8
5002
The filesystem is 
c orrupted .  
Detec ted by the 
filesystem d river 
after the system is 
up  and running .  
Op erations 
c ontinue b ut the 
filesystem will b e 
marked  unc lean 
when unmountedMINORUNIX_FS
Invoke the RESET SYSTEM REBOOT sc reen 
whic h will c ause 
fsc k to run ag ainst the 
filesystem and  c lean it up .
5003
No free i-nod es WARNINGUNIX_FS
This is a symptom of some other p roblem in 
th e  sys...

Page 132

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-10  
8
5200
Proc ess d eath MAJORALOG
System automatic ally restarts twic e, then 
reboots twic e. If this fails,
— Restore g eneric  filesystems using  
Stand alone Utilities. 5201
Proc ess 
initialization failureMAJORALOG
5202
Proc ess sanity 
failedMAJORALOG
5203
Proc ess error 
rep orted  No alarmALOG
Used  internally. Alarm is never ac tive.
5204
Unab le to op en the 
ac tivity log  file. The 
ac tivity log  feature 
is not...

Page 133

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-11  
8
5500
Post b ox lib rary 
timeoutMAJORAUDIT_PBOX
System automatic ally restarts twic e, then 
reboots twic e. If this fails,
— Restore g eneric  filesystems using  
Stand alone Utilities. 5501
Cannot make p ost 
boxMAJORAUDIT_PBOX
5502
Post b ox is not 
p resentMAJORAUDIT_PBOX
5600
Post b ox lib rary 
timeoutMAJORPHANT
5601
Proc ess error 
rep orted  No alarmPHANT
Used  internally. Alarm is never ac tive.
5700
Proc ess d...

Page 134

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-12  
8
6103
Sanity up d ate 
failedMAJOROAMSTATE
— Restore from the generic  MO d isk
— If system d oes not return to AUDIX state, 
or error/fault reoc c urs, shut d own the system 
via the c onsole or b y using the shutd own 
button, and rep lac e the MFB.
6106
Angel problems MAJOROAMSTATE
— Restore from the generic  MO d isk.
— If system d oes not return to AUDIX state, 
or error/fault reoc c urs, shut d own the system 
via...

Page 135

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-13  
8
Tab le 8-2, Sof t w are  Er ro rs, lists the errors logg ed  in the D ISPL AY ERRORS log . These 
errors g enerate the ab ove faults. Note that p seud onyms of listed error resourc es 
may app ear on the error log ; these “ hid d en”  resourc es are listed  in p arenthesis 
with their related  resourc es. 
6500
Post b ox lib rary 
timeoutMAJORCLT_PBOX
System automatic ally restarts twic e, then 
reboots twic e. If this...

Page 136

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-14  
8
ADATA 116
Proc ess error SOFTWARE 3
ADATA_PBOX 80
Initialization MP 10 ab orted (make a p ost b ox)SOFTWARE 101
ADATA_PBOX 81
Diag nostic  MP 10 failed (make a p ost b ox)SOFTWARE 101
ADATA_PBOX 81
Diag nostic  MP 12 failed (c hec k if p ost b ox is 
op erational)SOFTWARE 102
ADATA_PBOX 81
Diag nostic  MP 75 failed (restart the system)SOFTWARE 100
ADATA_PBOX 81
Initialization MP 10 failed  (make a p ost b ox)SOFTWARE 101...

Page 137

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-15  
8
AFIO 81
Period ic  MP 15 failed (c hec k p roc ess sanity)SOFTWARE 402
AFIO 112
Proc ess d ied  SOFTWARE 401
AFIO 116
Proc ess error SOFTWARE 403
AFIO_PBOX 80
Initialization MP 10 ab orted (make a p ost b ox)SOFTWARE 501
AFIO_PBOX 81
Diag nostic  MP 10 failed (make a p ost b ox)SOFTWARE 501
AFIO_PBOX 81
Diag nostic  MP 12 failed (c hec k if p ost b ox is 
op erational)SOFTWARE 502
AFIO_PBOX 81
Diag nostic  MP 75 failed...

Page 138

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-16  
8
ALOG 70
Ac tivity log  seek errorSOFTWARE 5207
ALOG 71
Ac tivity log  open suc c eed edSOFTWARE 5204
ALOG 72
Ac tivity log  read  suc c eededSOFTWARE 5205
ALOG 73
Ac tivity log  write suc c eed edSOFTWARE 5206
ALOG 74
Ac tivity log  seek suc c eed edSOFTWARE 5207
ALOG 80
Initialization MP 13 ab orted (make a p roc ess)SOFTWARE 5201
ALOG 80
Initialization MP 15 ab orted (c hec k p roc ess 
sanity)SOFTWARE 5202
ALOG 81
Diag...

Page 139

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-17  
8
ANET 116
Proc ess error SOFTWARE 903
ANET_PBOX 80
Initialization MP 10 ab orted (make a p ost b ox)SOFTWARE 1001
ANET_PBOX 81
Diag nostic  MP 10 failed (make a p ost b ox)SOFTWARE 1001
ANET_PBOX 81
Diag nostic  MP 12 failed (c hec k if p ost b ox is 
op erational)SOFTWARE 1002
ANET_PBOX 81
Diag nostic  MP 75 failed (restart the system)SOFTWARE 1000
ANET_PBOX 81
Initialization MP 10 failed  (make a p ost b ox)SOFTWARE...

Page 140

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Software 
8-18  
8
AUDIT 81
Diag nostic  MP 75 failed (restart the system)SOFTWARE 5400
AUDIT 81
Initialization MP 13 failed  (make a p roc ess)SOFTWARE 5401
AUDIT 81
Initialization MP 15 failed  (c hec k p roc ess sanity)SOFTWARE 5402
AUDIT 81
Period ic  MP 15 failed (c hec k p roc ess sanity)SOFTWARE 5402
AUDIT 112
Proc ess d ied  SOFTWARE 5401
AUDIT 116
Proc ess error SOFTWARE 5403
AUDIT_PBOX 80
Initialization MP 10 ab orted (make a p...
Start reading Lucent Technologies Definity Audix System Release 4.0 Maintenance Guide

Related Manuals for Lucent Technologies Definity Audix System Release 4.0 Maintenance Guide

All Lucent Technologies manuals