Page 91

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Voice, Control, and LAN Links 
5-17 LAN Problems 
5
Tab le 5-15, Test LAN Results, lists ind ivid ual Loc al Area Network tests and  test 
results when 
TEST L AN is run, and  p ossib le rep air ac tions. 
Table 5-14. Local Area Network (LAN) Errors 
Error
ResourceError
Code DescriptionFault
ResourceFault
Code
LANINTF 81
Diag nostic  MP 160 failed  (resets LAN interfac e 
chip)LANINTF 0
LANINTF 81
Diag nostic  MP 162 failed  (firmware...

Page 92

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Voice, Control, and LAN Links 
5-18 LAN Problems 
5
External loop  aroundP Pa s se d
F Failed See fault c od e 3 rep air ac tions
A Ethernet 
hard ware failedInd ic ates hard ware loop test 
failed
A Firmware loop  
failedInd ic ates firmware loop test 
failed
A No g ateway 
IP add ressExamine 
system-p arameters 
imapi data
A (anything  
else)Call RSC (examine error log )
Get hard ware idP v2.02 
i0000a5c d 37
00v is fw version, i is...

Page 93

Digital Networking 
6-1 Networking Port Alarms 
6
DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
6
Digital Networking
This c hapter d isc usses Digital Networking  in the DEFINITY AUDIX System. It 
inc lud es alarms, rep air p roc edures, errors, and  tests for networking  p orts and  
remote mac hines.
Networking Port Alarms
Tab le 6-1 NET_PORT Alarms and  Rep air Proc ed ures, lists alarms and  rep air 
p roc ed ures ad dressed  to NET_PORT. Rep air ac tions are p erformed one at a...

Page 94

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-2 Networking Port Alarms 
6
Table 6-1. NET_PORT Alarms and Repair Procedures
Fault 
Code Fault
DescriptionAlarm
LevelError Log
ResourceRepair
Action
0 Software resourc es 
(ACCE p roc ess or its 
p ostb ox) assoc iated 
with the p ort c annot 
b e initialized  or the 
ACCE p roc ess d iedMAJOR NET_PORT,
ACCE, or 
ACCE_PBOX—  Proc ess restarts 
automatic ally. Manually 
reb oot.
— Restore from generic .
1 The c...

Page 95

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-3 Networking Port Alarms 
6
Networking Port Errors
Tab le 6-2 lists networking  port error and  fault c od es.
Table 6-2. Networking Port Errors
Error ResourceError 
Code Description Fault ResourceFault 
Code
NET_PORT 24 No switc h response NET_PORT 2
NET_PORT 80 MP 10 (make p ostbp ox for ACCE p roc ess) ab orted NET_PORT 0
NET_PORT 80 MP 11 (remove p ostbox for ACCE proc ess) ab orted NET_PORT 0
NET_PORT 80 MP 13 (c...

Page 96

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-4 Networking Port Test Results 
6
Networking Port Test Results
Th e  test network-port  c ommand  runs the d efault (short) network 
p ort test, whic h is a set of non-intrusive tests verifying  b asic  op eration of the 
network port and  assoc iated  DSP.
Tab le 6-3 lists network p ort results
 for the short network p ort test.
NOTE:
Th e  short test c hec ks most of the software and  the hard ware involved  in the...

Page 97

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-5 Networking Port Test Results 
6
NOTE:
Th e  Reset network port test 
ab orts unless the p ort is b usied  out.
Th e test network-port 
 64k-start-loop 
c ommand  runs the 
64k-start-loop  test whic h p uts the ind ic ated  p ort in 64kb ps loop around  mod e. 
The p ort is restored  to its normal mod e b y running  test network -port 
 
stop-loop
. Only run these tests if there is more than one d ig ital networking...

Page 98

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-6 Networking Port Test Results 
6
Tab le 6-5 lists network p ort results for the 64k-start-loop 
and 56k start-loop.
NOTE:
The 64k start loop  test ab orts unless the p ort is in-servic e and  id le.
test network-port 
 stop-loop 
c ommand  runs the stop -loop test whic h 
returns the ind ic ated  p ort to its normal mod e after having  b een p ut into 64k or 
56k loop around  via either the 
64k-start-loop or...

Page 99

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-7 Remote Machine Alarms 
6
Remote Machine Alarms
The following alarms may be raised  on resourc e MACHINE, c orresp ond ing to a 
sp ec ific  remote mac hine. In all c ases, the error log  resourc e is MACHINE. In the 
alarm, event, and  error log s, the loc ation for MACHINE resourc es is the remote 
mac hine’s voic e id  as d isp layed on the list mac hine form. Alarms ag ainst remote 
mac hines b elong  to alarm...

Page 100

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Digital Networking 
6-8 Remote Machine Errors 
6
Remote Machine Errors
Tab le 6-8 lists MACHINE errors and  fault c od es for remote mac hines.
Remote Machine Test
Test mac hine d oes not g enerate the alarm, it resolves the alarm b y:
nSp ec ifying  the mac hine b y voic e id  or b y name
nOptionally sp ec ifying  whic h p ort to use
nAutomatic ally c amp ing on if p ort is c urrently b usy
nDisp laying  q uasi real-time status of test c...
Start reading Lucent Technologies Definity Audix System Release 4.0 Maintenance Guide