Page 61
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 TN568 Circuit Pack 3-15 System Time 3 Tab le 3-8, Sy st e m Ti m e Er ro rs, lists the errors log g ed in the D ISPLAY ERRORS sc reen. These errors may g enerate the ab ove alarms. Table 3-8. System Time Errors Error ResourceError Code DescriptionFault ResourceFault Code SYS_TIME 80 Initialization MP 53 ab orted (valid ates system time)SYS_TIME 0 SYS_TIME 81 Diag nostic MP 31 failed (c hec ks switc h time ag ainst system...
Page 62
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 TN568 Circuit Pack 3-16 TN568 Board Replacement 3 TN568 Board Replacement Follow the step s b elow to rep lac e the TN568. !WARNING: Static elec tric ity c an b e destruc tive to system p arts. Use an anti-static wrist strap whenever removing or installing a DEFINITY AUDIX System. Also use an anti-static mat when taking the system ap art to rep lac e the c irc uit p ac k or storag e d evic es. 1. Ensure that the c ustomer knows...
Page 63
SCSI Devices 4-1 Magneto-Optical Drive Problems 4 DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 4 SCSI Devices This c hapter lists errors and alarms that may oc c ur to the MO d rive or hard d isk d rive. Refer to the alarm log tab le for rep air p roc ed ures and to the error log tab le to b etter und erstand what eq uip ment errors will trig ger eac h alarm. Magneto-Optical Drive Problems Errors that oc c ur d uring normal MO-drive op eration are rec ord ed in the system...
Page 64
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-2 Magneto-Optical Drive Problems 4 Th e STATUS MO-DISK c ommand rep orts the following : nif the MO d rive is eq uip p ed nthe vend or nthe model number nthe vend or’s revision numb er nif the MO d isk is eq uip p ed nif the MO d isk is writing enab led nthe MO disk capacity Refer to Ta b l e 4 - 1 for a list of alarms and repair p roc ed ures ad d ressed to the MO d rive. Perform rep air ac tions one at a time until...
Page 65
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-3 Magneto-Optical Drive Problems 4 Tab le 4-2 lists the MO d isk errors log g ed in the D I SPL AY ERRO RS sc reen. These errors may g enerate the ab ove alarms. 1 Hard ware (d evic e) Fa i lu r eMINORMO_DISK — Test the MO d rive using the STATUS MO-DISK sc reen. — Chec k the c ab les. — Insert another MO d isk. — Rep lac e the MO d rive. — Rep lac e the TN568. 2 Bac kup Job Failed WARNINGMO_DISK — Run a manual b ac...
Page 66
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-4 Magneto-Optical Drive Problems 4 Ta b l e 4 - 3 lists the test MO tests, what is shown on the sc reen when they p ass, fail or ab ort, and p ossib le rep air ac tions. SCSI_MO 182 A Bac kup Job Retry FailedMO_DISK 2 SCSI_MO 185 Corrup t FilesystemMO_DISK 3 SCSI_MO 186 Filesystem okMO_DISK 3 SCSI_MO 195 A Bac kup Job PassedMO_DISK 2 Ta b l e 4 - 3 . Te s t M O R e s u l t s Te s t N a m eTest Result (Passed)...
Page 67
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-5 Magneto-Optical Drive Problems 4 On-Site Task: MO Disk Replacement The system ad ministrator is req uired to rep lac e the MO d isk. Read /write MOP Passed F Fa i le d A Ad d mo-disk first Ad d mo-disk A Ad d mo-disk in progWait until ad d is d one. Chec k status mo-disk until inservic e id le. A Typ e is not Bac kup Remove g eneric MO disk and put in backup MO d isk. A Mo-d isk is write protChange write p rotec...
Page 68
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-6 Hard Disk Problems 4 Hard Disk Problems Except for normal inline error detection, and periodic background tests, which oc c ur every 30 sec ond s, no tests are manually p erformed on the hard d isk d rive using sc reens. The d isk drive c annot b e b usied out. Use the STATUS DISK c ommand to d isp lay the c urrent values of the d isk d rive, listed b elow. Bring ing up this sc reen will also invoke a d isk b ac...
Page 69
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-7 Hard Disk Problems 4 Tab le 4-5, Disk Drive Errors, lists the errors logg ed in the D ISPL AY ERRO RS sc reen. These errors may g enerate the ab ove alarms. Table 4-5. Disk Drive Errors Error ResourceError Code DescriptionFault ResourceFault Code SCSI_HD 80 Initialization MP 57 ab orted (aud its d isk files)DISK 1 SCSI_HD 81 Diag nostic MP 57 failed (aud its d isk files)DISK 1 SCSI_HD 81 Initialization MP 57 failed...
Page 70
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-8 Disk/MO Drive Replacement Procedures 4 Disk/MO Drive Replacement Procedures Refer to Fi g u re 4 -1, Sid e View of DEFINITY AUDIX System, when replacing the disk or MO drive. Figure 4-1. Side View of DEFINITY AUDIX System Emer Reset Shutdown ckdx568e LJK 020599 Hard disk drive standoffs (4)Magneto-optical disk drive LEDs Securing latch MO disk drive standoffs (4) Hard drive power cable Hard drive SCSI cable MO power...