Page 71

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
SCSI Devices 
4-9 Disk/MO Drive Replacement Procedures 
4
The only tool req uired  to remove the d isk d rive or the MO drive is either a 1/4-inc h 
nut d rive or a blad ed  flat-head  sc rewd river. To remove either the hard  d isk d rive 
or the MO d rive c omp lete the following  steps.
!WARNING:
Static  elec tric ity c an b e destruc tive to system p arts. Use an anti-static  wrist 
strap  whenever removing  or installing  a DEFINITY...

Page 72

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
SCSI Devices 
4-10 Disk/MO Drive Replacement Procedures 
4
Figure 4-2. Removing Standoffs from Back of Circuit Pack
7. Plac e the c irc uit p ac k to the sid e.
8. Remove the SCSI bus c ab le and  p ower c ab le from the d rive.
9. Remove the four stand offs from the d rive.
E
m
e
r R
e
s
e
t
S
h
u
td
ow
n
ckdx568c LJK 020599 

Page 73

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
SCSI Devices 
4-11 Disk/MO Drive Replacement Procedures 
4
To mount either d rive: 
1. Screw the four standoffs onto the new drive.
2. Alig n the c irc uit b oard  over the stand offs with the d rive in the c orrec t 
orientation. Insert the four sc rews that attac h the d rive to the c irc uit p ac k. 
For the MO drive, the slot for inserting  the MO d isk should  b e fac ing  the 
fac ep late. For the hard  d isk, the SCSI c onnec tion...

Page 74

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
SCSI Devices 
4-12 Disk/MO Drive Replacement Procedures 
4
Figure 4-3. Back View of Hard Disk Drive with Jumper locations
drdxsea LJK 021299
Jumper
location
Jumper
location
Jumper
location 

Page 75

Voice, Control, and LAN Links 
5-1 Voice Port Problems 
5
DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
5
Voice, Control, and LAN Links
Voice Port Problems
Alarms ag ainst a voic e p ort will d isap p ear: 
nWhen the system is restarted  
nIf it b ec omes unad ministered 
nWhen it is busied out (this c auses a warning alarm whic h will end  when the 
port is 
released) 
nWhen error c ond itions stop  over a period  of time (“ leaky b uc ket” ) 
nWhen an automatic  test of the alarm c...

Page 76

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Voice, Control, and LAN Links 
5-2 Voice Port Problems 
5
Table 5-1. Voice Port Alarms and Repair Procedures 
Fault
CodeFault
DescriptionAlarm
LevelError Log
ResourceRepair
Action
0
Unab le to restart 
Voic e Session 
ControllerMAJORVOICE_PT
The system automatic ally reinitializes the 
port. 1
VSC software 
manager fails to 
initializeMINORVOICE_PT
2
VSC p roc ess sanity 
failedMINORVOICE_PT
3
Switch port busied WARNINGVOICE_PT
Release the...

Page 77

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Voice, Control, and LAN Links 
5-3 Voice Port Problems 
5
Tab le 5-2, Vo i c e  Po r t  E r r o r s, lists the errors whic h, if exc eed ing  a c ertain 
threshold, may g enerate the listed  faults. They are log ged  in the 
D ISPL AY ERRO RS 
sc reen. Note that p seudonyms of listed error resourc es may ap p ear on the error 
log; these hid d en resourc es are listed  in p arenthesis with their related  resourc es. 
Refer to the list of ab...

Page 78

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Voice, Control, and LAN Links 
5-4 Voice Port Problems 
5
VOICE_PT 80
Initialization MP 24 aborted  (make p ost b ox for VSC)VOICE_PT 0
VOICE_PT 80
Initialization MP 29 aborted  (c all SD to c onfigure voic e 
port)VOICE_PT 4
VOICE_PT 80
Initialization MP 6 aborted  (c reate VSC p roc ess)VOICE_PT 1
VOICE_PT 80
Initialization MP 74 aborted  (c hec k sanity of VCS sanity)VOICE_PT 2
VOICE_PT 81
Diagnostic  MP 134 failed  (forc ib ly id les p...

Page 79

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Voice, Control, and LAN Links 
5-5 Voice Port Problems 
5
Fi g u re  5 - 3, Te s t  P o r t  R e s u l t s, lists ind ividual tests and  p ass/fail/ab ort information 
that ap p ear on the sc reen when 
TEST PO RT is run, and  p ossib le rep air ac tions.
VOICE_PT 81
Shutd own seq uenc e MP 5 failed  (kill VSC proc ess)VOICE_PT 0
VOICE_PT 81
Diagnostic  MP 127 failed  (reb oot system)VOICE_PT 11
VOICE_PT 81
Diagnostic  MP 142 failed  (test...

Page 80

DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
May 1999
Voice, Control, and LAN Links 
5-6 Voice Port Problems 
5
Ta b l e  5 - 3 . Te s t  P o r t  R e s u l t s  
Test Name (Passed) (Failed) (Abort) Action
Te st  Vo i c e  
Po r tP Pa ss e d
 F See Admin Log See ad min log
A c annot alloc  
portSwitc h has ac tivated a port while 
AUDIX has b usied  them out. 
(Chec k with RSC)
A Port not 
busiedBusyout p ort, try ag ain
A Test ac tive Someone else testing? (Chec k 
with RSC)
A Cannot b usy...