Page 211

INTER-TELPRACTICES 
IMX/GMX 416/832 INSTALLATION & -ANCE INSTALLATION 
Issue 1, November 1994 
FIGURE 3-71. INTER-TELDVK U/S-LINE KEYSET “SMALL” LCD 
INS’lALLATION 
FACEPLATE ASSEMBLY (INSIDE VIEW) 
DISPLAY 
WINDOW 
LCD 
CONNECTOR 
RIBBON 
CABLE 
LCD UNll 
CONTROL 
BOARD 
Page 3-127  

Page 212

INSTALLATION 
Issue 1. November 1994 INTER-TELPRACTICES 
IMX/GMX 416/832 INSTALLATION & MAINTENANCE 
Keyset Installation 
733 Install all Inter-Tel/DVK keysets as follows: 
NOTE: For information on installing the GX and GMX 
keysets, see appendixes A and B in the back of this 
manual. 
(1) Before mounting the modular jack assembly and 
connecting the keyset, measure the voltage on 
the RED terminal of the modular jack assembly 
with respect to the GREEN terminal. (The “com- 
mon” probe of the voltmeter...

Page 213

INTER-TELPRACTICES 
IMX/GMX 416/832 INSlALLATION & -ANCE INSTALLATION 
Issue 1, November 1994 
xl. 
0. 
S. 
t. 
ceiver via the primary voice path. (Display 
keysets show KTS SELF-TEST HOT 
HANDSET PRI.) 
While speaking into the handset transmitter, 
determine that sidetone is being received 
over the handset receiver. 
press and release the hookswitch. The hand- 
set transmitter is connected to the handset re- 
ceiver via the secondary voice path. (Display 
keysets show KTS SELF-TEST HOT 
HANDSET SEC.)...

Page 214

INSTALLATION 
Issue 1, November 1994 INTER-TELPRACTICES 
IMX/GMX 416/832 INSTALIATION & MAINTENANCE 
Optional Data Port Modules 
736 All Inter-Tel/DVK keysets may be equipped with 
optional Data Port Modules (refer to REPLACEMENT 
PARTS for the part number). The Data Port Module con- 
tains a four-conductor modular jack that can be used to 
connect either a data device (such as a personal comput- 
er with a direct-connect modem) or an LRA and an ex- 
ternal signaling device (such as a loud bell, horn,...

Page 215

INTER-TELPRACTICES INSTALLATION 
lMX/GMX 416/832 INsmLLATION & MAINTENANCE Issue 1, November 1994 
FIGURE 3-72. INTER-TELJDVK DATA PORT MODULE INSTALLATION 
SE-ITING FOR 
DATA DEVICE SElTlNG 
FOR LRA 
MODULAR 
JACK 
PLUG LOCATION 
(on keyset control 
bc=Jl 
Page 3-131  

Page 216

INSTALIAITON Issue 1, November 1994 INTER-TELPRACTICES 
JMX/GMX 416/832 INSTALLATION & MAINTENANCE 
7Al To connect a Loud Ringii Adapter (LRA): 
The optional Data Port Module can be used to connect 
external signaling equipment such as loud bells, horns, 
flashing lights, etc. to a keyset. This application is useful 
in areas where the normal ring tone of the keyset cannot 
be heard, such as warehouses and loading docks. The 
signaling device follows the normal ringing patterns of 
the keyset. 
NOTE...

Page 217

INTER-TELPRACTICES 
IMX/GMX 416/832 INSTALLATION & MAINTENANCE INSTALLATION 
Issue 1, November 1994 
D. IMX 416/832 DIGITAL DSS/BLF UNlT 
INSTALLATION 
7.44 Up to 50 digital keysets can be equipped with up 
to four digital Direct Station Selection/Busy Lamp Field 
(DWBLF) Units each. Each single DSWBLF Unit has 
60 keys for directly accessing up to 60 numbers. The 
numbers can be station extension numbers, hunt group 
pilot numbers, or other system features. 
NOTE: The system can have as many as 50...

Page 218

DBTALLATION 
Issue 1, November 1994 lNTER-TEL4PRACTIcES 
JMX/GMX 416/832 INS’IALLATION & MAINTENANCE 
FIGURE 3-74. BACK OF DIGITAL DSS/BLF UNIT 
RS-232-C RS-232-C 
CONNECTOR CONNECTOR 
TO KEYSET PC DATA TO 2ND DSS/BLF 
PORT MODULE UNn; IF INSTALLED 
I 
POWER CONNECTOR 
TO AC TRANSFORMER 
/ 
I 
I / Y 
b 
J2 / 
/ 0 
, 
/ 
 
INSIDE OF BASEPLATE BACK OF DIGITAL DSS/BLF UNIT 
‘.. 
 
A ::z: 
J1 A El g$; 
.,.. .v,.,.,.,...,.,. ,.,........ .,.,..... 
B 
0 .::&>: 
.A...& 
‘.:~:;:~:.. m 
Q 
Q 
Page 3-134  

Page 219

INTER-TELPRACTICES 
IMX/GMX 416/832 INSTALLATION % MAINTENANCE INSTALLATION 
Issue 1, November 1994 
E. ITMX 416/832 ANALOG DSS/BI,F UNIT 
INSTALLATION 
m 7.48 
Up to 50 IMX Direct Station Selection/Busy 
Lamp Field (DSWBLF) Units can be installed on the 
IMX 416/832 System. A Keyset Card (KSC or KSC-D) 
can support up to four analog units. Each DSS/BLF Unit 
has 60 keys for directly accessing up to 60 numbers. The 
numbers can be station extension numbers, hunt group 
I pilot numbers, or other system...

Page 220

INSTALLATION Issue 1, November 1994 INTER-TELPRACTICES 
IMWGMX 416/832 INSTALLATION 8z MAINTENANCE 
F. GMX-416/832 ANALOG DSS/BLF TJNlT 
INSTAUATION 
1 752 Up to 50 single or tandem Direct Station Selec- 
tion/Busy Lamp Field @SS/BLF) Units can be installed 
on the system. A Keyset Card can support up to four 
units. Each single DSS/BLF Unit has 60 keys for direct- 
ly accessing up to 60 numbers. The numbers can be ei- 
ther station extension numbers or hunt group pilot 
numbers. The numbers can be...
Start reading Inter-Tel Imx/Gmx 416/832 Installation Manual

Related Manuals for Inter-Tel Imx/Gmx 416/832 Installation Manual

All Inter-Tel manuals