GE S5 Service Manual
Have a look at the manual GE S5 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Appendix B, ElectroMagnetic Compatibility B-5 Document no. M1031517-02 Table 4 Recommended separation distances between portable and mobile RF communications equipment and the S/5™ CAM/ CCCM (1 For impedance RESP measurement. For invasive pressure measurement in M-series modules except M-PRE(S)TN. The invasive pressure measurement compliance level is dependent on the transducer used, and only the lower level is guaranteed for all transducers. (2 For BIS measurement in E-BIS/M-BIS, RESP measurement in M-(P)RE(S)TN and invasive pressure measurement in M-COPSv/E-COPSv and M-COP/E-COP modules. The invasive pressure measurement compliance level is dependent on the transducer used, and only the lower level is guaranteed for all transducers. Recommended separation distances between portable and mobile RF communications equipment and the S/5™ CAM/ CCCM. The S/5™ CAM/ CCCM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the S/5™ CAM/ CCCM can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the S/5™ CAM/ CCCM as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter WSeparation distance according to frequency of transmitter m 150 kHz to 80 MHz (1 80 MHz to 800 MHz (2 80 MHz to 800 MHz (2 0.01 0.12 0.35 (1 0.12 0.35 (2 0.23 0.70 (2 0.1 0.38 1.1 (1 0.38 1.1 (2 0.73 2.2 (2 11.2 3.5 (1 1.2 3.5 (2 2.3 7.0 (2 10 3.8 11 (1 3.8 11 (2 7.3 22 (2 100 12 35 (1 12 35 (2 23 70 (2 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. d1.2P = d3.5P = d1.2P = d3.5P = d2.3P = d7P =
All specifications are subject to change without notice. CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed medical practitioner. Outside the USA, check local laws for any restriction that may apply. Document no. M1031518-02 March, 2006 Datex-Ohmeda Inc. P.O. Box 7550 Madison, WI 53707-7550, USA Tel: +1 608 221 1551 Fax: +1 608 222 9147 GE Healthcare Finland Oy Helsinki, Finland P.O. Box 900 FI-00031 GE, FINLAND Tel: +358 10 39411 Fax: +358 9 1463310 www.gehealthcare.com Copyright 2006 General Electric Company Datex-Ohmeda S/5 TM Compact Anesthesia Monitor S/5 TM Compact Critical Care Monitor Planned Maintenance Instructions
Table of contents i Document no. M1031518-02 Table of contents Table of contents i 1 Planned maintenance instructions 1 1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Recommended tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2.1 Hemodynamic patient simulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.3 Recommended parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.4 Planned maintenance parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.4.1 PM parts for Compact Airway Modules, E-CXXXXX/ M-CXXXXX without CO2 absorber - Anesthesia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.4.2 PM parts for Compact Airway Modules, E-CXXXXX/ M-CXXXXX without CO2 absorber - Critical Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.4.3 PM parts for Compact Airway Modules, E-CXXXXX/ M-CXXXXX with CO2 absorber - Anesthesia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4.4 PM parts for Compact Airway Modules, E-CXXXXX/ M-CXXXXX with CO2 absorber - Critical Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4.5 PM parts for Airway Module, E-miniC/ M-miniC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 Planned maintenance check list 8 2.1 Visual inspection/preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1.2 Compact Airway Module, E-CXXXXX/ M-CXXXXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1.3 Single-width Airway Module, E-miniC/ M-miniC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.1.4 Tonometry Module, E-TONO/ M-TONO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.1.5 Recorder Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.1.6 Modules with NIBP measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 2.2 Functional inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 2.2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 2.2.2 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 2.2.3 Keyboard(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 2.2.4 Display Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 2.2.5 Frame Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 2.2.6 Compact Airway Module, E-CXXXXX/ M-CXXXXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 2.2.7 Single-width Airway Module, E-miniC/ M-miniC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 2.2.8 Tonometry Module, E-TONO/ M-TONO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 2.2.9 Multiparameter Hemodynamic Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 2.2.10 EEG Module, E-EEG/ M-EEG and EEG Headbox, N-EEG. . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 2.2.11 BIS Module, E-BIS/ M-BIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 2.2.12 Entropy Module, E-ENTROPY/ M-ENTROPY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 2.2.13 Pressure/Pressure Temp Modules, E-P, E-PT, M-P, M-PT. . . . . . . . . . . . . . . . . . . . . . . . . . . .19 2.2.14 Dual pressure Module, E-PP, M-PP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 2.2.15 Cardiac Output Modules, E-COP, E-COPSv, M-COP, M-COPSv . . . . . . . . . . . . . . . . . . . . . . .19 2.2.16 NIBP module, M-NIBP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 2.2.17 NeuroMuscular Module, E-NMT, M-NMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 2.2.18 Nellcor Compatible Saturation module, E-NSAT, M-NSAT. . . . . . . . . . . . . . . . . . . . . . . . . . .21 2.2.19 Datex-Ohmeda Oxygen Saturation module, M-OSAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors ii Document no. M1031518-02 2.2.20 Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 2.2.21 Recorder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 2.2.22 Network Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 2.2.23 Wireless Network Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 2.2.24 Interface Module, E-INT, M-INT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 2.2.25 Device Interfacing Solution, N-DISxxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 2.2.26 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Appendix A: Planned maintenance check form, S/5 Compact Monitors A-1
Planned maintenance instructions 1 Document no. M1031518-02 1 Planned maintenance instructions 1.1 Introduction These instructions include procedures for planned maintenance (PM) for the Datex-Ohmeda S/5 Compact Anesthesia Monitor and S/5 Compact Critical Care Monitor. The Planned maintenance should be performed once a year. These instructions include “Planned maintenance check form, S/5 Compact Monitors” to be filled in when performing the corresponding procedures. The symbol in the instructions means that the procedure performed should be signed in the check form. The procedures should be performed in ascending order, bypassing those that are not applicable for a particular monitor. If you need further information on how to perform a certain Planned maintenance procedure, please refer to the corresponding slot in the Technical Reference Manual. All menu selections related to the Datex-Ohmeda monitors are written in the following typeface: e.g. Parameters - Gas Unit As you enter the service menus, you need following passwords: Monitor Setup - Install/Service (password 16-4-34) - Service (password 26-23-8) In case you evaluate the measurement accuracy with a patient simulator, add the simulator’s accuracy specification to the one for the monitor. 1.2 Recommended tools For product(s) Tool Order No. All Airway modulesFlowmeter Compact Airway Module, E-CAiO(VX)/ M-CAiO(VX)Calibration gas and regulator 755583/755534* Compact Airway Module, E-COVX/ M-COVX Calibration gas and regulator 755587/755534* Compact Airway Module, E-CO(V), M-C, M-CO(V)Calibration gas and regulator 755581/755534* E-miniC/ M-miniC Calibration gas and regulator 755580/755534* Compact Airway Module, E-COVX, E-CAiOVX, M-COVX, M-CAiOVXSampling line, 2 m 73318 All Airway modules w/ (V) Spirometry tube, 2 m 890031 All Airway modules w/ (V) D-lite 733950 All Airway modules Sampling line, 6 m/19.7 ft 73306 Hemodynamic modules Hemodynamic modules w/ (P), M-NIBPNIBP cuff and hose 2753E (cuff) 877235 (hose)
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 2 Document no. M1031518-02 Hemodynamic modules w/ (P) InvBP transducer 70077-001 Multi-Link ECG accessories, IEC E-PSM(P)/ E-PRESTN/ M-PRESTN - Multi-link 3-leadwire set 412682-003 - Multi-link 5-leadwire set 412681-003 - Multi-link 5-leadwire set, C2-C6 416467-004 E-PRESTN/ M-PRESTN w/ (E12) - Multi-link 12-lead ECG trunk cable 416035-002 or Multi-Link ECG accessories, AHA E-PSM(P)/ E-PRESTN/ M-PRESTN - Multi-link 3-leadwire set 412682-001 - Multi-link 5-leadwire set 4162681-001 - Multi-link 5-leadwire set, V2-V6 416467-003 E-PRESTN/ M-PRESTN w/ (E12) - Multi-link 12-lead ECG trunk cable 416035-001 M-NESTPR 3-lead ECG trunk cable 545302 M-NESTPR 5-lead ECG cable 545303 M-NE12STPR 10-leadwire ECG cable 545324 E-PSM(P)/ E-PRESTN SpO 2 finger probe OXY-F-UN SpO 2 Interconnect Cable OXY-ES3 M-PRESTN SpO 2 finger probe OXY-F4-N or SAS-F4 E-NSAT/ M-NSAT Nellcor SpO 2 probe Hemodynamic modules w/ (T) Temperature test set 884515 Hemodynamic E-Modules w/ (NIBP) Adult NIBP cuff hose with cuff ID 2021285-001 Infant cuff hose without cuff ID 414874-001 Hemodynamic M-Modules w/ (NIBP) Adult NIBP cuff 572435 Adult NIBP cuff hose 877235 E-COP, E-COPSv, M-COP, M-COPSv C.O. Catheter cable 16590 E-COPSv/ M-COPSv SvO 2 simulator 890121 Tonometry Module, E-TONO/ M-TONO Calibration gas and regulator 755580/755534 Sampling line 733251 Luer plug Pressure manometer Tonometrics TM catheterTONO-14F or another suitable TONO-_F catheter EEG Module, E-EEG/ M-EEG Earphones EEG simulator 90502 For product(s) Tool Order No.
Planned maintenance instructions 3 Document no. M1031518-02 NOTE: * Ensure that the calibration gas and regulator are functioning properly before calibration. Perform annual maintenance on the regulator as required. For more information see section “Adjustments and calibrations” in Compact Airway modules slot. 1.2.1 Hemodynamic patient simulators The following tables present the patient simulators’ compatibility with each hemodynamic module, and the accessories needed: Table 1 Patient simulators’ compatibility with each hemodynamic module BIS Module, E-BIS/ M-BIS BIS simulator or BIS Sensor simulator900509 900508 E-ENTROPY/ M-ENTROPY Simulator for M-ENTROPY N-ES Entropy sensor cable 8002964 E-NMT/ M-NMT NMT simulator 871251 NMT ElectroSensor 888416 NMT sensor cable 888415 MemCard – Menu 893860 (English) MemCard – Data 887045 (English) All M-Modules Screwdrivers All E-Modules Torx screwdrivers; T8, T10 Module ParameterPatient simulator M1010831 MedSim 874027 E-PSM(P),E-PRESTN ECG Ok Multilink ECG acc. Not compatible T402015-004 402015-004 and M1010832 InvBP OkM1010858 For product(s) Tool Order No. ECG
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 4 Document no. M1031518-02 Table 2 Adapter cables for hemodynamic patient simulators 1.3 Recommended parts M-PRESTN ECG Ok Multilink ECG acc. Not compatible TOkM1010832 M1010832 InvBP Not compatible Ok Ok M-NESTPR ECG Not compatible 300 series acc. Ok 12 lead ECG Not compatible 300 series acc. Not compatible TOkM1010832 M1010832 InvBP Not compatible Ok Ok Patient simulator Adapter cables for simulators Hemodynamic patient simulator Dual temperature adapter cable 402015-004 Hemodynamic patient simulator Dual Inv.BP adapter cable 2005772-001 Medsim Temperature adapter cable M1010832 Medsim Inv.BP adapter cable M1010858 Lionheart & MPS450 Temperature adapter cable M1010846 Lionheart & MPS450 Inv.BP adapter cable M1010862 For product(s) Part Order No. CM(C) Frame Unit Fan filter 896085 CM(C) Display Unit Fan filter 874594 Central Processing Board Battery for SRAM/Timekeeper 197230 Recorder paper 74205 Tonometry Module, E-TONO/ M-TONO 733382 Module ParameterPatient simulator M1010831 MedSim 874027 NIBP ECGSpO T1 T2P1 P2 2 Auto On/OffStart CancelZero P1Zero P2 T2 P1 P2T1 NIBP ECG+ RespSpO2