GE S5 Service Manual
Have a look at the manual GE S5 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Appendix A, Service check form, S/5 Compact Anesthesia Monitor, S/5 Compact Critical Care Monitor A-3 Document no. M1031520-02 MemCard Option S/N OK N.A. Fail OK N.A. Fail 34. Memory option recognition 35. Memories and PCMCIA controller test 36. Interface status 37. Menu Card recognition 38. Card type recognition 39. Data Card recognition 40. Save and Load Modes 41. Data Card functions Notes Network Option S/N OK N.A. Fail OK N.A. Fail 42. Connection to Network 43. Ethernet address ___________________ 44. Data counters 45. Data error counters 46. Hardware error counters 47. Disconnection recognition 48. ID-plug recognition Notes Wireless LAN option S/N OK N.A. Fail OK N.A. Fail 49. Signal strength 50. Configure access point ___________________ 51. Connection to the Network Notes
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors A-4 Document no. M1031520-02 General OK N.A. Fail OK N.A. Fail 52. Trend retaining 53. Service reset switch check 54. Battery capacity 55. Service Log reset 56. Electrical safety check 57. Final cleaning Notes Used spare parts Signature
All specifications are subject to change without notice. CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed medical practitioner. Outside the USA, check local laws for any restriction that may apply. Document no. M1044470-01 March, 2006 Datex-Ohmeda Inc. P.O. Box 7550 Madison, WI 53707-7550, USA Tel: +1 608 221 1551 Fax: +1 608 222 9147 GE Healthcare Finland Oy Helsinki, Finland P.O. Box 900 FI-00031 GE, FINLAND Tel: +358 10 39411 Fax: +358 9 1463310 www.gehealthcare.com Copyright 2006 General Electric Company Datex-Ohmeda S/5 TM Compact Anesthesia Monitor, F-CM1 (Rev. 04), F-CMREC1 (Rev. 01); Frame Unit AC/DC Power Supply Unit S/5 TM Compact Critical Care Monitor, F-CMC1 (Rev. 04), F-CMCREC1 (Rev.01); Frame Unit AC/DC Power Supply Unit Technical Reference Manual
Table of contents i Document no. M1044470-01 Table of contents Table of contents i Introduction 1 1 Specifications 2 2 Functional description 3 2.1 PMB connector board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.2 Connector board PMB-REC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.3 PMB (Power Management Board) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.4 Module motherboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.5 AC/DC Power Supply Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.6 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.7 Frame Unit Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.8 In-built Recorder Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.9 Connectors and signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.9.1 External Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.9.2 Serial Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 3 Service procedures 11 3.1 General service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3.2 Service check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3.2.1 Recommended tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3.2.2 Recommended parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3.2.3 Before beginning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 3.2.4 Visual inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 3.2.5 Functional inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 3.2.6 Recorder Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 3.2.7 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 3.3 Disassembly and reassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 3.3.1 To remove the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 3.3.2 To remove the AC/DC Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 3.3.3 To disassemble the Side Frame Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 3.3.4 To detach/remove the PMB Board (Power Managemet Board) . . . . . . . . . . . . . . . . . . . . . . .19 3.3.5 To detach/remove the Module Mother Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 3.3.6 To remove the Recorder Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 3.3.7 Adjustment and Calibrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 3.4 Internal battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 3.4.1 Battery time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 3.4.2 Refreshing the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 3.4.3 Replacing the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 4 Troubleshooting 23 4.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 4.2 Recorder Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 4.2.1 Troubleshooting chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 5 Earlier revisions 26
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors ii Document no. M1044470-01 Appendix A: Service check form, S/5 Compact Anesthesia Monitor, S/5 Compact Critical Care Monitor A-1
Frame Unit for F-CM(C)1 (rev. 04), F-CM(C)REC1 (Rev. 01) 1 Document no. M1044470-01 Introduction This section provides information about the maintenance and service of the following products: •S/5 Compact Anesthesia Monitor frame F-CM1 and S/5 Compact Critical Care Monitor frame F-CMC1 (including the AC/DC power unit, battery and Power Management Board). •S/5 Compact Anesthesia Monitor frame F-CMREC1 and S/5 Compact Critical Care Monitor frame F-CMCREC1 (in addition to the above mentioned parts also a built-in recorder). All the service menus related to the monitor are described in a separate “Service Menu” slot and the spare part lists in the “Compact Monitors Spare Parts” slot. NOTE: Printings on thermal paper may be destroyed when exposed to light, heat, alcohol, etc. Take a photocopy for archive.
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 2 Document no. M1044470-01 1 Specifications Dimensions 335 x 205 x 340 mm /13.2 x 8.1 x 13.4in (W x D x H) Weight 8.5 kg (19.4 lbs) (w/o modules) Electrical Requirements Power supply Rated voltage range and frequencies 100 to 240 VAC 50/60 Hz (limits 90-264 VAC) Stability ±10 % of nominal voltage Power consumption 140 VA (max) Fuses 2x2A, T/SLOW, 250 V Grounding Hospital grade Interruptability Data memory and alarm settings are saved up to 15 minutes after monitor standby Battery Battery type NiMH, 3.5Ah Battery charging time 10 hours to full capacity Battery operation up to 1.5 hours typical on full charge at 23 °C / 73 °F Recharging when connected to mains power Battery operaton alarm early warning ‘Battery low’ note final warning ‘Battery low’ alarm Battery state indicator Capacity bar displayed on the screen Environmental Requirements Operating temperature 10 - 35 °C / 50 - 95 °F Storage temperature -10 - 50 °C / 14 - 122 °F Atmospheric pressure 500 - 800 mmHg (660 - 1060 mbar, 66 - 106kPa) Humidity 10 - 90 % non-condensing In-built recorder Power consumption 3 W Principle Thermal array Print resolution Vertical 8 dots/mm (200 dots/inch) Horizontal 32 dots/mm (800 dots/inch) at a speed of 25 mm/s and slower Paper width 50 mm, printing width 48 mm Traces Selectable 1, 2, or 3 traces Print speed 1, 6.25, 12.5, 25 mm/s
Frame Unit for F-CM(C)1 (rev. 04), F-CM(C)REC1 (Rev. 01) 3 Document no. M1044470-01 2 Functional description The Frame Unit consists of the following parts: •PMB (Power Management Board) •PMB connector board(s) •connector board PMB-REC (in the side frame unit) •two batteries •AC/DC power unit •optionally in-built recorder The left side of the Frame Unit has places for two double-width modules or four single-width modules. The network signals are led through their own cables to the Frame Unit. The connectors are placed on the left side of the Frame Unit in frame version F-CM(C)1 (rev.04). In frame versions F-CM(C)(REC) (rev.00...03) the connectors are placed on the back plate of the Frame Unit. The serial data interface is led through the Frame Unit to the AC/DC power unit. The serial connector is located at the side of the AC/DC power unit.
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 4 Document no. M1044470-01 Figure 1 Frame block diagram 2.1 PMB connector board The PMB connector boards are small boards connected together by a ribbon cable and are both equipped with the D-25 connectors, one for AC/DC unit and the other for the Display Unit. The board with the Display Unit connector has also a 16-pin connector for the PMB board. The PMB connector boards route signals between the AC/DC unit, PMB board and Display Unit. Signals are transferred via a ribbon cable between the D-connector boards (connected to the AC/DC and DU). Power lines are transferred separately through the PMB. 2.2 Connector board PMB-REC The connector board PMB-REC is the one mounted in the Side Frame unit, and connected to the PMB board via a 15-pin D-connector when inserted into the frame. The connector board PMB-REC routes operating voltage and signals for the frame cooling fan and for the recorder unit (optional). PMB board Battery #1Battery #2 Fan Sideplate connector board Recorder 25-pin D-connector25-pin D-connector CM1 frame Module motherboard Module connectors CM1_frame_block_diag.vsd