GE Logiq P5 Service Manual
Here you can view all the pages of manual GE Logiq P5 Service Manual. The GE manuals for Medical Equipment are available online for free. You can easily download all the documents as PDF.
Page 201
GE HEALTHCARE DIRECTION 5394141, REVISION 1LOGIQ™ P5 SERVICE MANUAL Section 5-4 - Main Board Detail 5 - 59 Section 5-13Fast Polling 5-13-1 General This describes Fast Polling feature that will change the polling rate to 15 seconds for 10 minutes. 5-13-2 Enabling Fast Polling 1.) Right Click on “Con nect to GE” icon. 2.) Pressing “OK” will change the polling rate to 15 seconds for 10 minutes. Figure 5-63 Figure 5-64 Agent Configuration
Page 202
GE HEALTHCARE DIRECTION 5394141, REVISION 1LOGIQ™ P5 SERVICE MANUAL 5 - 60Section 5-4 - Main Board Detail This page was intentionally left blank.
Page 203
GE HEALTHCARE DIRECTION 5394141, REVISION 1 LOGIQ™ P5 SERVICE MANUAL Section 6-1 - Overview 6 - 1 Chapter 6 Service Adjustments Section 6-1 Overview 6-1-1 Purpose of this chapter 6 This section describes how to test and adjust the scanner. These tests are optional. You may use them to check the system for errors. Section 6-2 Regulatory Verify, where applicable, that any regulatory information or tests required by national law are present and accounted for, and any regulatory tests required by...
Page 204
GE HEALTHCARE DIRECTION 5394141, REVISION 1 LOGIQ™ P5 SERVICE MANUAL 6 - 2 Section 6-3 - Monitor Adjustments Section 6-3 Monitor Adjustments 6-3-1 Rotate and ti lt the monitor The monitor position can be adjusted for easy viewing. - The monitor can be rotated around its central pivot point. - The monitor can be tilted for the optimum viewing angle. - the monitor can be flipped up and down. NOTE: When moving the system, f lip down the monitor to its lowest possible position to improve stability....
Page 205
GE HEALTHCARE DIRECTION 5394141, REVISION 1 LOGIQ™ P5 SERVICE MANUAL Section 6-3 - Monitor Adjustments 6 - 3 6-3-2 Brightness and Contrast Adjusting the monitors contrast and brightness is one of the most important factors for proper image quality. If these controls are set incorrectly, th e Gain, TGC, Dynamic Range and even Power Output may have to be changed more often than necessary to compensate. The proper setup displays a complete gray scale. T he lowest level of black should just disappear...
Page 206
GE HEALTHCARE DIRECTION 5394141, REVISION 1 LOGIQ™ P5 SERVICE MANUAL 6 - 4 Section 6-3 - Monitor Adjustments 6-3-3 LCD Plastic filter 6-3-3-1 Tools • Common Phillips screwdrivers • Allen/Unbraco wrench • Stubby screwdriver (Flat tip and Cross tip) 6-3-3-2 Removal procedure 1.) Remove the Monitor cover set. Refer to the 8-2-2 Monitor cover set on page 8-5 and the figure below. 2.) Remove the LCD Plastic filter. 3.) Put the LCD plastic filter on the LCD monitor after detaching the tape of the LCD...
Page 207
GE HEALTHCARE DIRECTION 5394141, REVISION 1 LOGIQ™ P5 SERVICE MANUAL Section 6-3 - Monitor Adjustments 6 - 5 6-3-3-2 Removal procedure (cont’d) 4.) Perform the following functional tests. If all ar e successful, include the debrief script provided below. 6-3-3-3 Mounting Procedure 1.) Install the LCD monitor cover parts in the reve rse order of removal procedure. Refer to the 8-2-2 Monitor cover set on page 8-5 . 2.) Put the label on the rear of the LCD monitor. Table 6-2 Functional...
Page 208
GE HEALTHCARE DIRECTION 5394141, REVISION 1 LOGIQ™ P5 SERVICE MANUAL 6 - 6 Section 6-3 - Monitor Adjustments 6-3-4 Flexible LCD arm - locking mechanism Flexible LCD arm’s rotation movement can be adjusted by using the LCD arm’s locking mechanism. To unlock the LCD arm: 1.) Pull the LCD arm toggle knob and turn clockwise to unlock the LCD arm. To lock the LCD arm : 1.) Turn counter clockwise and push the LCD arm toggle knob and to lock the LCD arm. Figure 6-6 Unlocking the Flexible LCD arm Figure 6-7...
Page 209
GE HEALTHCARE DIRECTION 5394141, REVISION 1 LOGIQ™ P5 SERVICE MANUAL Section 6-4 - Trackball Cleaning 6 - 7 Section 6-4 Trackball Cleaning The trackball on the keyboard need to be cleaning periodically. 1.) Open the trackball Figure 6-8 Open Trackball Figure 6-9 Trackball Hole Remove dust inside of bucket
Page 210
GE HEALTHCARE DIRECTION 5394141, REVISION 1 LOGIQ™ P5 SERVICE MANUAL 6 - 8 Section 6-4 - Trackball Cleaning This page was intentionally left blank.