1. Configuration 
 
Chapter: PPG Configuration 
This chapter explains PPG configuration. 
 
1.
 Configuration 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CODE: 9BFPPGTOP-E01.2 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER  16-1: PPG Configuration 
MB9Axxx/MB9Bxxx  Series 
MN706-00002-1v0-E 
615  

Page 652

 
1. Configuration 
 
1. Configuration 
This section explains the unique PPG configuration. 
The following shows the unique PPG configuration. 
PPG output
GATE Signal Circuit
PPG1
PPG Trigger 
Enable Register
Timing Generator  Circuit 0
To interrupt unit
GATE signal (GATE0, GATE2, GATE4, GATE8, GATE10, GATE12)
RTO output
PPG module
PPG0
PPG2
PPG4
PPG3
PPG5
PPG7
PPG6
PPG8
PPG9
PPG10
PPG11
PPG12
PPG13
PPG14
PPG15
Multi Function Timer
Unit 0 
Multi Function TimerUnit 1 
RTO output
RTO output
RTO output
RTO...

Page 653

 
1. Configuration 
 FUJITSU SEMICONDUCTOR LIMITED 
Chapter: PPG Configuration 
FUJITSU SEMICONDUCTOR CONFIDENTIAL  4  
 Combinations of operation modes and  PPG channels with output enabled 
 
PPG channel 8-bit mode 8+8-bit mode  16-bit mode 16+16-bit mode 
PPG ch.0  PPG0 output PPG0 output 
PPG ch.1  Not available  PPG0 prescaler  PPG0 output 
PPG0 output 
PPG ch.2 PPG2 output PPG2 output 
PPG ch.3  Not available  PPG2 prescaler  PPG2 output 
PPG0 prescaler 
PPG ch.4 PPG4 output PPG4 output 
PPG ch.5...

Page 654

 
 
 
 FUJITSU SEMICONDUCTOR LIMITED 
MN706-00002-1v0-E 
618 
MB9Axxx/MB9Bxxx  Series  

Page 655

 
1. Overview 
 
Chapter: PPG 
This chapter describes the PPG timer. 
 
1.
 Overview 
2. Configuration and Block Diagrams 
3. Operations 
4. Setup Procedure Example 
5. Registers 
6. Notes 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CODE: 9BFPPG-E01.2 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER  16-2: PPG 
MN706-00002-1v0-E 
619 
MB9Axxx/MB9Bxxx  Series  

Page 656

 
1. Overview 
 
1. Overview 
This section describes the overview of PPG timer. 
The Programmable Pulse Generator (PPG) module can perform pulse output of arbitary cycle and duty ratio 
controled by timer operation. 
 Features of PPG module 
  8-bit PPG output 2-channel independent operating mode is supported. 
   16-bit PPG output operating mode is supported. 
   8+8-bit PPG output operating mode is supported. 
   16+16-bit PPG output operating mode is supported. 
   PPG can be inverted the output...

Page 657

 
2. Configuration and Block Diagrams 
 
2.  Configuration and Block Diagrams 
This section shows the configuration and block diagrams of PPG timer. 
 PPG circuit block diagram 
Figure 2-1  shows the block diagram of the PPG circuit. 
Figure 2-1 PPG circuit block diagram  
PPG output
APB
SignalAPB
Interface
PPG Output  Circuit
Interrupt 
Output Circuit
Control 
Registers
DOWN counter
Reload Circuit To interrupt unit
GATE signal from multifunction timer
PPG module
GATE Signal 
Circuit
PPG Trigger...

Page 658

 
2. Configuration and Block Diagrams 
 
 Timing generator block diagram 
Figure 2-2  and Figure 2-3  show the block diagram of timing generator circuits 0 and 1, respectively. 
Figure 2-2 Block diagram of timing generator circuit 0 
 
FUJITSU SEMICONDUCTOR LIMITED 
 
STRMONI
 
Figure 2-3 Block diagram of timing generator circuit 1 
 
 
 
In Figure 2-2  and Figure 2-3 , PPGxTG(x=0,2,4,6,8,10,12,14) is a PPG start trigger signal. 
The Timi ng Ge

nerator Circuit consists of the following functional...

Page 659

 
3. Operations 
 
3. Operations 
This section shows the opration of PPG timer. 
 
3.1 PPG circuit operations  
3.2  Timing generator circuit operations 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER  16-2: PPG 
MN706-00002-1v0-E 
623 
MB9Axxx/MB9Bxxx  Series  

Page 660

 
3. Operations 
 
3.1.  PPG circuit operations 
The PPG module can output pulse signals having arbitary cycle and duty ratio. 
The pulse output can be controlled based on the timer operation. 
 PPG functions 
The PPG timer starts decrem enting the down counter value being set in the LOW width reload register by 
triggered. During this time, the output is set to LOW.  After an underflow occurs, the output is inverted to 
HIGH. Then, the PPG timer starts decrementing the value being set in the HIGH width...