    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 261
    ConfidentialDISASSEMBLY FLOWCHART
    A4B1
    A1
    B2
    A2
    B3
    A3
    B4B5
    Start
    Right Rear Cover + Rear Cover
    (P. 262)
    High Voltage Unit (HV1)
    (P. 262)
    Front Door(P. 264)Right Door(P. 264)
    Standard cassette
    (P. 267)
    Optional Cassette
    (P. 268)
    Near Empty Assy
    (P. 269) 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 262
    Confidential
    Right Rear Cover + Rear Cover
    1. Open the Right Door [1].
    2. Remove three Screws [2], and remove the Right Rear Cover [3].
    3. Remove nine Screws [4], and remove the Rear Cover [5].
    A1
    B1
    [1]
    [3] [2] [4][4] [4]
    [5]
    High Voltage Unit (HV1)
    1. Disconnect four Connectors [1].
    2. Remove five Screws [2] and the Tab [3], and remove the High Voltage Unit [4].
    A2
    B2
    [1][2]
    [3]
    [4] 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 263
    Confidential
    Make sure following things when installing the High Voltage Unit (HV1).†
    Terminal end surely contacts (Refer to Figure 1).
    †
    Tab [5] surely set up (Refer to Figure 2).
    Terminal end position
    4038F2C087DA
     Figure 1 Figure 2
    †
    Be cautious not to install the wrong Screw because two types of Screws [2] are 
    used.  • M Mark: Screws for installing metallic parts (Space between thread is small).
      • P Mark: Screws for installing plastic parts (Space between thread is large).
    P MarkM Mark 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 264
    Confidential
    Front Door
    1. Open the Front Door.
    2. Remove the Screw [1] each to remove the Right and Left Stoppers [2].
    3. Pull out the Right and Left Pins [3] to remove the Front Door [4].
    A3
    [1] [4][2]
    4038F2C038DB
    [3]
    4038F2C039DA
    Right Door
    1. Open the Right Door.
    2. Remove three Screws [1], and remove the Reinforcement plate [2] of the right door and 
    spring [3].
    	
    
    Remove the Spring with its tension loosened by declining right before the Left Door is 
    closed.A4
    [1]
    [2] [3]
    4039F2C510DA 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 265
    Confidential3. Remove the Shoulder Screw [4].
    4. Remove two Screws [5], and remove the Metal blanking plate [6].
    [5]
    [6]
    [4]
    4039F2C511DA
    5. Remove two Screws [7] and remove the Rear Handle Assy Protect Cover [8].
    6. Remove five Screws [9] and the Connector [10], and remove the Rear Handle Assy [11].
    [9] [9] [10]
    [11]
    [9]
    4039F2C513DA
    [7]
    [8] 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 266
    Confidential7. Disconnect four Connectors [12].
    8. Slide out the Paper Cassette 1.
    [12][12] [12]
    [12]
    4039F2C514DA
    9. Remove two Screws [13], and remove the Front Right Cover [14].
    [14] [13]
    [13]
    4039F2C515DA 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 267
    Confidential10.Remove the Screw [15], and remove the Shaft [16].
    11.Remove the Right Door [17].
    [15][17]
    [16]
    4039F2C516DA
    Paper Cassette 1
    1. Slide out the Standard Paper Cassette [1]. 
    B3
    [1] 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 268
    Confidential2. Slide out the Standard Paper Cassette with pressing the Slide Locks [2] at both ends.
    [2][2]
    Optional Cassette
    1. Slide out the Optional Cassette [1].
    B4
    [1] 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 269
    Confidential2. Remove the Screw [2] and remove the Stopper [3].
    3. Remove the Optional Cassette with while pressing the Slide Lock [4].
    [3]
    [4] [2]
    Near Empty Assy
    1. Pick up and remove the Actuator from the front side.
    2. Remove the Screw [1] from the rear side.
    B5
    [1] 
    						
    							EPSON AcuLaser C9200NRevision D
    DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 270
    Confidential3. Put the Near Empty Assy [2] through the hole of the Flame bringing down the Near Empty 
    [2] Assy to the rear side from the front side.
    [2]
    4.  Remove two Connectors and remove the Near Empty Assy.
    When installing, insert the white Connector into the Connector of the front side [3] 
    and insert the blue Connector into the Connector of the rear side [4].
    [3]