EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 201 Confidential2. Remove two Connectors [2], the Type-B Guide rail [3], and three Harnesses [4]. 3. Remove nine Screws [5], and remove the Controller Board [6]. [2] [3] [4][4] [5] [5][5] [6] [5] Exit Tray 1. Open the Upper Fusing Cover [2]. 2. Remove two Claws [3], and remove the Upper Fusing Cover [2]. B3 C3 [2] [3] [3] 4039F2C019DA
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 202 Confidential3. Remove two Screws [5], and remove the Exit Sensor Holder [6]. 4. Remove three Screws [7], and remove the Exit Tray [8]. [5] [6] [7] [8] Controller Board Mounting Bracket 1. Remove three Wire Saddles [1], six Screws [6], and four Clamp Cores [3], then remove the Flat Cable Cover. B4 C4 [1] [2] [2] [4] [3]
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 203 Confidential2. Remove eleven Screws [5] and release the Edge Cover [6], and remove the Controller Board Mounting Bracket [7]. [5] [5] [5] [5] [7] [6] Mechanical Control Board (PWB-M) 1. Remove all the Connectors and Flat Cables on the Mechanical Control Board. 2. Remove six Screws [8] and remove the Mechanical Control Board [9]. B5 [8] [9] [8]
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 204 Confidential † When the Mechanical Control Board (PWB-M) is replaced, relocate the Parameter Chip (IC6). † Mount the Parameter Chip (IC6) of old Mechanical Control Board onto the new Mechanical Control Board. † When the Parameter Chip (IC6) is mounted, precisely fit the directions of each “A.” † When installing the Mechanical Control Board (PWB-M) , secure the Harness to the original location with the Wire Saddle. † When the Control Board is replaced, be sure to update the Firmware to the latest version. 4037F2C061DB 4037F2C534DA A AParameter Chip (IC6) † Be careful when assembling since there are some Connectors which are not used on the Mechanical Control Board (PWB-M). Not Used (CNSKF)Not Used (CNTM)
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 205 Confidential RTC Board (PWB-R) 1. Disconnect the Connector [1], and remove two Screws [2], and remove the RTC Board [3]. C5 [2] [3] [1] 4039F2C034DA
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 206 Confidential4.3.6 Group 6CONTENT DISASSEMBLY FLOWCHART Parts/Units to be Disassembled Guide Standard Paper CassettePaper Width Detection Unit AB A Standard Paper Cassette Paper Width Detection Unit B B1 A1 B2B3 Standard Paper Cassette (P. 207)Start Optional Cassette (P. 208) Paper Width Detection Unit (P. 209) *When the Optional Cassette is installed
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 207 Confidential Standard Paper Cassette 1. Slide out the Standard Paper Cassette [1]. A1 B1 [1] 2. Slide out the Standard Paper Cassette with pressing the Slide Locks [2] at both ends. [2][2]
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 208 Confidential Optional Cassette 1. Slide out the Optional Cassette [1]. B2 [1] 2. Remove the Screw [2] and remove the Stopper [3]. 3. Remove the Optional Cassette with while pressing the Slide Lock [4]. [3] [4] [2]
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 209 Confidential Paper Width Detection Unit 1. Remove the Paper Width Detection Unit pushing it toward the Right Door, with pushing the Knob [A] on the upper inside wall of the Tray toward the Right Door. B3 [1] [A] 2. Remove two Connectors and release the Harness from the tab of the Paper Width Detection Unit, then remove the Paper Width Detection Unit. † When the Paper Width Detection Unit has been removed, connect the Connector to the Sensor before installing the Sensor to the Unit, And then install the Unit to the Main Unit. This procedure make the work easier. † When installing the Paper Width Detection Unit, check four Claws of the Paper Width Detection Unit so that they dont come off the Main Unit.
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 210 Confidential4.3.7 Group 7CONTENT Parts/Units to be Disassembled Guide MP tray Left Cover + MP tray Right Cover + Tray ExtensionMulti Bypass UnitIDC Sensor/1 (SE1) + IDC Sensor/2 (SE2)Feed Roller (MP tray)Separation Roller (MP tray) ABCDE MP tray Right CoverA Tray Extension MP tray Left Cover A Multi Bypass Unit B A IDC Sensor/1 (SE1) IDC Sensor/2 (SE2) C C Feed Roller DE Separation Roller