/M/66-123DXP Pius Programming Instructions 7.1.25Day Restriction Level/Night Restriction LevelDescription: Use restriction level programming (Section 11.4) to create as many as eight different toll calling categories based on the freedom to dial various numbers or the restriction from dialing them. You can assign one of eight different restriction (1-8) levels or assign an “‘allow all” level or a “‘deny all” level. Level 8 is the least restrictive from a station viewpoint but the most restrictive from a...
Page 842
7.1.27Station Monitoring Description:When you enable this feature, the busy lamp field (BLF) light of an associated direct station select select (DSS) button provides a visual indication of idle, busy, and ringing status of the station it represents. A station user can press this DSS button to make a one-button pick-up of a ringing station. When you disable this feature, the BLF shows only idle and busy conditions of the DSS station.Programming: 1. Press CONTROL T for main menu. 2. From main menu, select...
Page 843
/M/66-123DXP Plus Programming Instructions 7.1.29Remote Station DisableDescription: The remote station disable feature, when enabled, allows users at stations with the proper class of service to dial a code and remotely disable or enable another station. Normally, you should give this capability to the system attendant but you can assign it to any class of service that is appropriate.Programming: 1 D Press CONTROL T for main menu. 2. From main menu, select stations and press ENTER. 3. From stations menu,...
Page 844
7.1.31Line AnswerDescription: This feature provides station access to a line for call answering purposes for an entire class of service of stations. Also refer to Section 7.1.32. You must turn on both that feature and this one for a line to be fully usable.Programming: 1.Press CONTROL T for main menu. 2.From main menu, select stations and press ENTER. 3.From stations menu, select COS programming and press ENTER. 4.Type class of service number (l-32) and press ENTER. 5.From COS programming menu, type...
Page 845
lMl66-123DXP Pius Programming Instructions 7.1.33Periodic Line Tone Description:This when enabled, provides periodic warning tones to station users while they are busy on certain lines. The warning tone consists of one 500 ms burst, a 100 ms off period, and one100 ms burst. The tone reminds the users to keep their conversations short on these lines. You can enable this feature for a class of service of telephones and then specify the particular lines that you deem applicable. Further, you can select...
Page 846
7.1.34Maximum Call Duration Description:The system provides the maximum call duration feature. This feature, when enabled, automatically cuts off calls on certain lines after a preprogrammed time. The system will not cut off calls made to an emergency number (Section 10.4). The system sounds a warning tone at the busy station 10 seconds before it disconnects the call. The warning tone consists of one 800 ms burst followed by eight 100 ms bursts. Also refer to Section 7.1.33 for a related feature....
Page 847
lMl66-123BXP Plus Programming Instructions 7.7.35Line Group Access Description:Use this procedure to give a station access to line groups. Refer to Section 8.2 for other line group considerations. Programming:1 0 Press CONTROL T for main menu. 2. From main menu, select stations and press ENTER. 3. From stations menu, select COS programming and press ENTER. 4. Type class of service number (l-32) and press ENTER. 5. From COS programming menu, type item number for feature and press ENTER. 6. Type line...
Page 848
7.1.37Line-To-Line Transfer (Unsupervised Conference)Description:This programming feature gives a station the ability to set up an unsupervised conference between two lines. Programming:1. Press CONTROL T for main menu. 2. From main menu, select stations and press ENTER. 3. From stations menu, select COS programming and press ENTER. 4. Type class of service number (l-32) and press ENTER. 5. From COS programming menu, type item number for feature and press ENTER. 6. Press SPACE bar for feature setting. 7....
Page 849
/M/66-123DXP Plus Programming Instructions 7.1.36Voice Announce BlockDescription: When you enable this programming feature a station has the ability to block voice announced internal signalling when its user dials the proper code.Programming: 1. Press CONTROL T for main menu. 2. From main menu, select stations and press ENTER. 3. From stations menu, select COS programming and press ENTER. 4. Type class of service number (l-32) and press ENTER. 5. From COS programming menu, type item number for feature...
Page 850
7.1.40Forced Account CodesDescription: After you have enabled the account code feature for the system, set its parameters, and programmed its list of account codes into the system, turn the feature on for a station class of service and make it either forced or optional.If you make it a forced account code, the user must enter an account code before the system will let him or her dial the number for an outgoing call.Also, on incoming calls a user must enter an account code before the system will allow him...