Canon scanner imageFORMULA DRG1130 User Manual
Here you can view all the pages of manual Canon scanner imageFORMULA DRG1130 User Manual. The Canon manuals for Scanner are available online for free. You can easily download all the documents as PDF.
Page 61
4-8 Chapter 4 Other Functions ■USB Short Packet Setting If the scanner does not operate normally when using the USB interface, change this setting to [OFF]. ■Tray Position Setting The document feed tray should be set to fit the number of document sheets to be loaded. (See “Preparing the Document Feed Tray” on p. 3-5.) 0: Up to 500 sheets 1: Up to 300 sheets 2: Up to 100 sheets ■Key Repeat Setting Selects the panel display method. ON: The panel display scrolls continuously while a key is pressed....
Page 62
Chapter 5 Maintenance 1. Regular Maintenance....................................... 5-2Cleaning the Scanner............................................5-2 Cleaning the Sensors ............................................5-2 Opening and closing the upper unit ......................5-3 Cleaning the Scanning Glass, Roller, and Pad .....5-3 Adjusting the Compression ...................................5-5 Auto Power OFF Function.....................................5-6 Power Outlet...
Page 63
5-2 Chapter 5 Maintenance 1. Regular Maintenance To maintain scanning quality, routinely clean the scanner as described below. CAUTION • Do not use spray cleaners to clean the scanner. Precision mechanisms may get wet and malfunction. • Never use paint thinner, alcohol, or other organic solvents to clean the scanner. Such solvents may deform or discolor the exterior of the scanner, and cause other damage. • When opening and closing the upper unit, be careful not to get your fingers caught, as this may...
Page 64
5-3 Chapter 5 Maintenance Main unit inner upper side (Upper Unit)Opening and closing the upper unit When cleaning the inside of the device, make sure to open and close the upper unit using the following procedure. CAUTION When opening and closing the upper unit, make sure not to catch your hand. ■Opening the Upper Unit Pull and hold the open/close lever, and open the unit smoothly until the upper unit stops. ■Closing the Upper Unit Smoothly close the upper unit (1). Further, press both ends of...
Page 65
5-4 Chapter 5 Maintenance 4. Wipe any dust off the scanning glass with a cleaning cloth or a clean, dry cloth. Make sure that you clean both scanning glasses, the one on the upper unit and the one on the main unit. CAUTION Never spray mild detergent or water directly on the scanning glasses. The spray could penetrate below the glass, and contaminate the internal light source and lenses. 5. Wipe the rollers using a moistened and firmly wrung- out cloth while rotating the rollers. The rollers are...
Page 66
5-5 Chapter 5 Maintenance IMPORTANT When wiping the pad, do not apply excessive force. Doing so may damage the pad. 9. Replace the rollers that you removed. (See “Removing and Reinstalling the Rollers” on p. 5-9.) 10. Smoothly close the upper unit. (See “Closing the Upper Unit” on p. 5-3.) IMPORTANT If paper jams or double feeds still occur frequently even after cleaning the rollers, roller replacement may be necessary. Contact your service representatives or Canon dealers. Adjusting the...
Page 67
5-6 Chapter 5 Maintenance 4. Change the [Reduction ratio adjustment] values. The adjustment value can be set in the range -3.0% to +3.0%. 5. Click [OK] to close the scanner properties. Auto Power OFF Function An auto power OFF function is built into the device. When the auto power OFF function is ON, the power supply automatically turns OFF after four hours have elapsed without a scan or other operation with the scanner. The auto power OFF function can be set using user mode. (See “User Mode”...
Page 68
5-7 Chapter 5 Maintenance 2. Replacing the Transport Rollers As the rollers start to wear out, feeding quality declines, and document feed errors, such as paper jams, become more likely. If document feed errors continue to occur after cleaning the rollers, purchase the Roller Replacement Kit and replace the transport rollers (pickup, feed, and retard rollers).Roller Replacement CycleThe feeding rollers are consumables that must be replaced after feeding about every 450,000 pages. When the rollers...
Page 69
5-8 Chapter 5 Maintenance 1. Press the Menu key on the control panel to activate the User Mode. 2. Press the [ ] key twice to display [Roller Counter]. 3. Check the number of pages fed by the rollers, and press [Enter].The counter reset mode is activated. 4. Press the [ ] key to select [RESET], and press [Enter]. The counter is reset to zero. 5. Press the [Stop] key to exit the User Mode. ■Verification and Reset Using the imageFORMULA Utility 1. Start Windows, and login as a user with administrator...
Page 70
5-9 Chapter 5 Maintenance The imageFORMULA utility will start. 3. Click [Canon DR-XXXX USB], and then click Properties. (XXXX depends on the model in use.) The scanner properties will be displayed. 4. Click [Reset]. The counter value of the Roller in use will be reset. 5. Click [OK] to close the scanner properties. Removing and Reinstalling the RollersFollow the procedure shown below to remove and reinstall the rollers when you need to clean or replace the Pickup, Feed, or Retard Rollers....