4-8 Chapter 4 Other Functions ■USB Short Packet Setting If the scanner does not operate normally when using the USB interface, change this setting to [OFF]. ■Tray Position Setting The document feed tray should be set to fit the number of document sheets to be loaded. (See “Preparing the Document Feed Tray” on p. 3-5.) 0: Up to 500 sheets 1: Up to 300 sheets 2: Up to 100 sheets ■Key Repeat Setting Selects the panel display method. ON: The panel display scrolls continuously while a key is pressed. OFF: The panel display scrolls each time a key is pressed. Hint Key repeat is valid in the following situations. • When using the Job Function • When selecting each of the functions in the User Mode ■Total Counter Displays the lifetime total number of document pages fed by the scanner. ■Roller Counter Displays the number of document pages fed since roller installation or replacement (pickup, feed, and retard rollers). Make sure to reset this counter when replacing the rollers. (See “Checking and Resetting the Page Counter” on p. 5-7.) ■Imprinter Test When the optional imprinter is installed, this function executes a test printing of the imprinter. (See “Performing an Imprinter Test” on p. 5-20.) ■Auto power OFF function settings Set the auto power OFF function. Select ON to enable the auto power OFF function, and if after 4 hours of inactivity, the power turns OFF automatically.
Chapter 5 Maintenance 1. Regular Maintenance....................................... 5-2Cleaning the Scanner............................................5-2 Cleaning the Sensors ............................................5-2 Opening and closing the upper unit ......................5-3 Cleaning the Scanning Glass, Roller, and Pad .....5-3 Adjusting the Compression ...................................5-5 Auto Power OFF Function.....................................5-6 Power Outlet .........................................................5-62. Replacing the Transport Rollers ...................... 5-7Roller Replacement Cycle.....................................5-7 Checking and Resetting the Page Counter ...........5-7 Removing and Reinstalling the Rollers .................5-93. Detaching and attaching the separation pad (retard roller cover) ........................................ 5-14When to replace the separation pad (retard roller cover)..............................................5-14 Detaching and attaching the separation pad (retard roller cover)..............................................5-144. Imprinter Ink Cartridge Replacement and Cleaning.................................................. 5-16About the Imprinter..............................................5-16 Replacing Ink Cartridges .....................................5-16 Specifying the Printing Position...........................5-18 Cleaning the Imprinter .........................................5-19 Imprinter Testing .................................................5-20
5-2 Chapter 5 Maintenance 1. Regular Maintenance To maintain scanning quality, routinely clean the scanner as described below. CAUTION • Do not use spray cleaners to clean the scanner. Precision mechanisms may get wet and malfunction. • Never use paint thinner, alcohol, or other organic solvents to clean the scanner. Such solvents may deform or discolor the exterior of the scanner, and cause other damage. • When opening and closing the upper unit, be careful not to get your fingers caught, as this may result in personal injury.Cleaning the Scanner■About the Cleaning Cloth Use the cleaning cloth supplied with the scanner to clean its interior. ■Cleaning the Scanner Exterior To clean the outside of the scanner, use a cloth moistened with water or mild detergent solution. Wring out the cloth thoroughly, and use a clean dry cloth to wipe the scanner dry. ■Cleaning the Document Feed Inlet and Transport Path Dust or paper particles in the document feed inlet or inside the scanner can cause spots to appear on scanned images. Use compressed air to periodically clean dust and paper particles from the inlet and the inside of the scanner. After completing large scanning jobs, turn OFF the scanner and clean out any paper particles. Cleaning the SensorsDust and debris that collect on the sensors may cause documents to be recognized incorrectly. Clean the sensors periodically using a blower, etc. so that dust and debris do not collect on them. Main unit inner lower side SensorsSensors
5-3 Chapter 5 Maintenance Main unit inner upper side (Upper Unit)Opening and closing the upper unit When cleaning the inside of the device, make sure to open and close the upper unit using the following procedure. CAUTION When opening and closing the upper unit, make sure not to catch your hand. ■Opening the Upper Unit Pull and hold the open/close lever, and open the unit smoothly until the upper unit stops. ■Closing the Upper Unit Smoothly close the upper unit (1). Further, press both ends of the upper unit to verify that it is securely closed. (2) Hint If the upper unit is open, an error is displayed. Cleaning the Scanning Glass, Roller, and Pad If there are streaks in the scanned images, or the scanned documents are dirty, it is possible that the scanning glass or rollers are dirty. Periodically clean the parts. IMPORTANT Scratches on the scanning glass may cause spots or streaks on scanned images, as well as feeding errors. If you find a scratch on the scanning glass, contact your local authorized Canon dealer or service representative to have the glass replaced.1. Turn the power switch off, and disconnect the power plug from the power outlet. 2. Close the document eject tray extension if it is open. 3. Open the upper unit smoothly. (See “Opening the Upper Unit” on p. 5-3) Sensors Open/close lever (1) (2)
5-4 Chapter 5 Maintenance 4. Wipe any dust off the scanning glass with a cleaning cloth or a clean, dry cloth. Make sure that you clean both scanning glasses, the one on the upper unit and the one on the main unit. CAUTION Never spray mild detergent or water directly on the scanning glasses. The spray could penetrate below the glass, and contaminate the internal light source and lenses. 5. Wipe the rollers using a moistened and firmly wrung- out cloth while rotating the rollers. The rollers are located at the positions indicated in the figure below. 6. Remove the pickup roller, feed roller, retard roller, and retard roller cover. (See “Removing and Reinstalling the Rollers” on p. 5-9.) IMPORTANT Remove the pickup roller, feed roller, and retard roller before wiping away the dirt. The pad is mounted to the retard roller cover. Wipe away the dirt from the pad once the retard roller cover has been removed from the device. 7. Wipe the rollers that you removed using a moistened and firmly wrung-out cloth. 8. Wipe away the dirt from the pad mounted to the retard roller cover while removed using a cloth that has been dipped in water and thoroughly wrung. Scanning GlassTransport RollerPickup Roller Feed Roller Platen Roller Retard Roller
5-5 Chapter 5 Maintenance IMPORTANT When wiping the pad, do not apply excessive force. Doing so may damage the pad. 9. Replace the rollers that you removed. (See “Removing and Reinstalling the Rollers” on p. 5-9.) 10. Smoothly close the upper unit. (See “Closing the Upper Unit” on p. 5-3.) IMPORTANT If paper jams or double feeds still occur frequently even after cleaning the rollers, roller replacement may be necessary. Contact your service representatives or Canon dealers. Adjusting the Compression If the roller mounted inside the scanner is worn, the scan images may become slightly elongated vertically. In this case, the image elongation can be suppressed by adjusting the compression. 1. Start Windows, and login as a user with administrator privileges. 2. Click the Start button, and then select [All programs], [Canon DR-XXXX], and [Canon imageFORMULA Utility]. XXXX depends on the model in use. Hint In Windows 8, the Canon imageFORMULA utility is saved to the following location.The imageFORMULA utility will start. 3. Click [CANON DR-XXXX USB], and then click Properties. XXXX depends on the model in use. The scanner properties will be displayed.
5-6 Chapter 5 Maintenance 4. Change the [Reduction ratio adjustment] values. The adjustment value can be set in the range -3.0% to +3.0%. 5. Click [OK] to close the scanner properties. Auto Power OFF Function An auto power OFF function is built into the device. When the auto power OFF function is ON, the power supply automatically turns OFF after four hours have elapsed without a scan or other operation with the scanner. The auto power OFF function can be set using user mode. (See “User Mode” on p. 4-4.)Power OutletIf you leave the power plug connected to the power outlet for a long period of time, dust may accumulate at the power outlet, and cause a fire or electrical shock. Clean the power plug and power outlet regularly.
5-7 Chapter 5 Maintenance 2. Replacing the Transport Rollers As the rollers start to wear out, feeding quality declines, and document feed errors, such as paper jams, become more likely. If document feed errors continue to occur after cleaning the rollers, purchase the Roller Replacement Kit and replace the transport rollers (pickup, feed, and retard rollers).Roller Replacement CycleThe feeding rollers are consumables that must be replaced after feeding about every 450,000 pages. When the rollers have fed more than 450,000 pages, a roller replacement message appears on the display panel whenever the scanner is turned ON. When the scanner is configured to reboot with the computer, a roller replacement message also appears on the computer screen. IMPORTANT • When the roller replacement message appears, purchase the Roller Replacement Kit and replace the rollers by following the relevant steps in the following sections. –(See “Removing and Reinstalling the Pickup Roller” on p. 5-10.) –(See “Removing and Reinstalling the Feed Roller” on p. 5-11.) –(See “Removing and Reinstalling the Retard Roller” on p. 5-12.) • When the rollers start to wear out, problems such as paper jams and document misfeeds may occur more frequently. If this happens, replace the rollers, regardless of the page count of the roller usage counter. • Messages on the display panel can be cleared by pressing the Count Clear key. However, the messages will continue to be displayed each time the scanner is turned ON until the roller counter is reset. • Make sure to reset the roller counter when replacing the rollers. (See “Checking and Resetting the Page Counter” on p. 5-7.) ■Roller Replacement Kit The Roller Replacement Kit consists of replacement pickup, feed, and retard rollers. For details, contact your local authorized Canon dealer or service representative. Product Name: Roller Replacement Kit Product Code: 8262B001 Checking and Resetting the Page CounterThe roller usage counter can be checked and reset using the Roller Counter in the User Mode setting. IMPORTANT • This counter shows the number of pages transported by the currently installed feed rollers. Make sure to reset the counter when you replace the rollers. • The Total Counter shows the total number of pages fed over the life of the scanner, and cannot be reset. Pickup Roller Feed Roller Retard Roller
5-8 Chapter 5 Maintenance 1. Press the Menu key on the control panel to activate the User Mode. 2. Press the [ ] key twice to display [Roller Counter]. 3. Check the number of pages fed by the rollers, and press [Enter].The counter reset mode is activated. 4. Press the [ ] key to select [RESET], and press [Enter]. The counter is reset to zero. 5. Press the [Stop] key to exit the User Mode. ■Verification and Reset Using the imageFORMULA Utility 1. Start Windows, and login as a user with administrator privileges. 2. Click the Start button, and then select [All programs], [Canon DR-XXXX], and [Canon imageFORMULA Utility]. (XXXX depends on the model in use.) Hint In Windows 8, the Canon imageFORMULA utility is saved to the following location. Menu KeyEnter Key
5-9 Chapter 5 Maintenance The imageFORMULA utility will start. 3. Click [Canon DR-XXXX USB], and then click Properties. (XXXX depends on the model in use.) The scanner properties will be displayed. 4. Click [Reset]. The counter value of the Roller in use will be reset. 5. Click [OK] to close the scanner properties. Removing and Reinstalling the RollersFollow the procedure shown below to remove and reinstall the rollers when you need to clean or replace the Pickup, Feed, or Retard Rollers. CAUTION • Turn OFF the power switch, and disconnect the power plug from the power outlet when you remove or reinstall the rollers. Leaving the power turned ON may result in an electric shock. • Do not place excessive force on the rollers when removing or reinstalling the rollers. Deformation of the rollers may cause feed errors. Pickup Roller Feed Roller Retard Roller