Page 251
6/02 2-221 DC1632/2240 12-262 Status Indicator RAPs Prelaunch Training/Review 12-262 Eject Clamp Home Sensor OffThe Eject Clamp Home Sensor does not turn off within 200ms after the Eject Clamp DOWN has started.ProcedureRemove the Eject Clamp Home Sensor bracket. (Leave the Connector plugged in) Enter dC330 [012-210] and press Start. Actuate the Eject Clamp Home Sensor with a sheet of paper. The display changes. YN Check the Eject Clamp Home Sensor using the Generic Transmissive Sensor RAP. Restore the...
Page 252
6/02 2-222DC1632/2240 12-262 Prelaunch Training/Review Status Indicator RAPsFigure 4 Finisher PWB
Page 253
6/02 2-223 DC1632/2240 12-267 Status Indicator RAPs Prelaunch Training/Review 12-267 DecurlerThe Decurler Cam Home Sensor did not actuate after the Decurler Cam Clutch energized.ProcedureOpen H Transport Cover and cheat the H Transport Cover Interlock Sensor (Figure 1). The H Transport Belts rotate. YN Go to the 12-100 RAP. Enter dC330 [012-217] and press Start. Rotate the Actuator and turn the Decurler Cam Home Sensor on/off. The display changes. YN Check the Decurler Cam Home Sensor using the Generic...
Page 254
6/02 2-224DC1632/2240 12-267 Prelaunch Training/Review Status Indicator RAPsFigure 5 Finisher PWB
Page 255
6/02 2-225 DC1632/2240 12-281 Status Indicator RAPs Prelaunch Training/Review 12-281 Set ClampThe Set Clamp Home Sensor does not turn on within 200ms after the Set Clamp has started operation.ProcedureEnter dC330 [012-211] and press Start. Rotate the Actuator and turn the Set Clamp Home Sensor on/off. The display changes. YN Check the Set Clamp Home Sensor using the Generic Transmissive Sensor RAP. Enter dC330 [012-040] and press Start. The Set Clamp Solenoid energized. YN Check the Set Clamp Solenoid...
Page 256
6/02 2-226DC1632/2240 12-281 Prelaunch Training/Review Status Indicator RAPsFigure 4 Finisher PWB
Page 257
6/02 2-227 DC1632/2240 12-301 Status Indicator RAPs Prelaunch Training/Review 12-301 Top Cover InterlockThe Top Cover Interlock is open.ProcedureCheat the Top Cover Interlock Switch. 12-301 is cleared. YN +5 VDC is measured between the Finisher PWB p/j (+) and Finisher PWB Chassis (- ). YN Replace the Finisher PWB (PL 17.13). +5 VDC is measured between the Top Cover Interlock Switch p/j (+) and Finisher PWB Chassis (-). YN Check the wire between the Top Cover Interlock Switch p/j and the Finisher PWB...
Page 258
6/02 2-228DC1632/2240 12-302 Prelaunch Training/Review Status Indicator RAPs 12-302 Front Door Interlock OpenThe Front Door Interlock is open.ProcedureCheat the Front Door Interlock Switch. Has the display of 012-302 been cleared. YN +5 VDC is measured between the Finisher PWB p/j (+) and Finisher PWB Chassis (- ). YN Replace the Finisher PWB (PL 17.13). +5 VDC is measured between the Front Door Interlock Switch p/j (+) and Finisher PWB Chassis (-). YN Check the wire between the Front Door Interlock...
Page 259
6/02 2-229 DC1632/2240 12-303 Status Indicator RAPs Prelaunch Training/Review 12-303 H Transport Interlock OpenThe H Transport Interlock Sensor detected open.ProcedureBlock the H Transport Interlock Sensor with a sheet of paper. Has the display of 012-303 been cleared. YN +5 VDC is measured between the Finisher PWB p/j (+) and Finisher PWB Chassis (- ). YN Replace the Finisher PWB (PL 17.13). +5 VDC is measured between the H Transport Interlock Sensor p/j (+) and Finisher PWB Chassis (-). YN Check the...
Page 260
6/02 2-230DC1632/2240 12-305 Prelaunch Training/Review Status Indicator RAPs 12-305 Docking Interlock OpenThe Docking Interlock is open.ProcedureBlock the Docking Interlock Sensor with a sheet of paper. Has the display of 012-305 been cleared. YN +5 VDC is measured between the Finisher PWB p/j (+) and Finisher PWB Chassis (- ). YN Replace the Finisher PWB (PL 17.13). +5 VDC is measured between the Docking Interlock Sensor p/j (+) and Finisher PWB Chassis (-). YN Check the wire between the Docking...