Page 281
6/02 2-251 DC1632/2240 15-362, 15-367Status Indicator RAPs Prelaunch Training/Review 15-362 X Hard FailureCommunication Failure.ProcedureSwitch the power off then on. The problem continues. YN Return to Service Call Procedures. Check the connectors on the IIT/IPS PWB (PL 18.3). If the check ia OK, replace the IIT/IPS PWB (PL 18.3). 15-367 X PIO FailureCommunication Failure.ProcedureSwitch the power off then on. The problem continues. YN Return to Service Call Procedures. Check the connectors on the...
Page 282
6/02 2-252DC1632/2240 15-370, 15-371 Prelaunch Training/Review Status Indicator RAPs 15-370 X PIO Initialization Failure 1Communication Failure.ProcedureSwitch the power off then on. The problem continues. YN Return to Service Call Procedures. Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL 18.3). 15-371 X PIO Initialization Failure 2Communication Failure.ProcedureSwitch...
Page 283
6/02 2-253 DC1632/2240 15-372, 15-375Status Indicator RAPs Prelaunch Training/Review 15-372 X PIO Initialization Failure 3Communication Failure.ProcedureSwitch the power off then on. The problem continues. YN Return to Service Call Procedures. Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL 18.3). 15-375 X PIO Before Scan Failure Communication Failure.ProcedureSwitch the...
Page 284
6/02 2-254DC1632/2240 15-376, 15-377 Prelaunch Training/Review Status Indicator RAPs 15-376 X PIO Non-match Failure 1Communication Failure.ProcedureSwitch the power off then on. The problem continues. YN Return to Service Call Procedures. Check the connectors on the IIT/IPS PWB (PL 18.3) and the ESS PWB (PL 13.1). If the check ia OK, replace the ESS PWB (PL 13.1). If the problem continues, replace the IIT/IPS PWB (PL 18.3). 15-377 X PIO Non-match Failure 2 Communication Failure.ProcedureSwitch the power...
Page 285
6/02 2-255 DC1632/2240 15-380, 15-381Status Indicator RAPs Prelaunch Training/Review 15-380 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 1 red failed.Initial Actionsï Verify that Platen Glass is installed correctly. ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required. Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates. YN Go to the 6-371 Exposure Lamp RAP. The Exposure Lamp illumination is bright and steady. YN Go to p/j722 and p/j724 on BSD 6.1...
Page 286
6/02 2-256DC1632/2240 15-382, 15-383 Prelaunch Training/Review Status Indicator RAPs 15-382 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 3 green failed.Initial Actionsï Verify that Platen Glass is installed correctly. ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required. Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates. YN Go to the 6-371 Exposure Lamp RAP. The Exposure Lamp illumination is bright and steady. YN Go to p/j722 and p/j724 on BSD...
Page 287
6/02 2-257 DC1632/2240 15-384, 15-385Status Indicator RAPs Prelaunch Training/Review 15-384 CCD AGCAutomatic Gain Control (AGC) for CCD Channel 5 blue failed.Initial Actionsï Verify that Platen Glass is installed correctly. ï Verify that NVM 715-400 = 1ProcedureNOTE: Refer the BSD 6.1, 6.2 and 6.7 as required. Enter dC330 [6-002] and press Start. The Exposure Lamp illuminates. YN Go to the 6-371 Exposure Lamp RAP. The Exposure Lamp illumination is bright and steady. YN Go to p/j722 and p/j724 on BSD 6.1...
Page 288
6/02 2-258DC1632/2240 15-790 Prelaunch Training/Review Status Indicator RAPs 15-790 X Detail Failure Communication Failure.ProcedureSwitch the power off then on. The problem continues. YN Check the connectors on the IIT/IPS PWB (PL 18.3). If the check ia OK, replace the IIT/ IPS PWB (PL 18.3). Return to Service Call Procedures.
Page 289
6/02 2-259 DC1632/2240 16-311, 16-315Status Indicator RAPs Prelaunch Training/Review 16-311 ScannerScanner not detected during power up.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Check connections between Scanner and IOT. Service as required (PL 18.3) (PL 18.4). 16-315 IIT InterfaceIIT interface error.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Pivot down T5 T6 HVPS (REP 1.6) to access I/F PWB....
Page 290
6/02 2-260DC1632/2240 16-316, 16-317 Prelaunch Training/Review Status Indicator RAPs 16-316 Page MemoryPage memory not detected.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Check installation of Page Memory of the Scanner. 16-317 Page MemoryPage Memory error.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Replace the Page Memory of the Scanner.