Page 301
6/02 2-271 DC1632/2240 16-721, 16-726Status Indicator RAPs Prelaunch Training/Review 16-721 Other ErrorsAn error occurred during printing that is not defined.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Run the same job again to check the error status and ask Support G for help. 16-726 Decomposer Auto JudgementCannot switch decomposer; a print Language auto judgement error occurred. Auto Judgement ErrorProcedureSwitch power off then on. The problem...
Page 302
6/02 2-272DC1632/2240 16-728, 16-729 Prelaunch Training/Review Status Indicator RAPs 16-728 TIFF DataThe data contains a Tag that is not set in the Image File Expansion Library.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Delete the unsupported Tag from the data and retry printing, etc. 16-729 TIFF DataThe specified settings exceed the upper limit of the valid number of colors and pixels.ProcedureSwitch power off then on. The problem continues. YN...
Page 303
6/02 2-273 DC1632/2240 16-730, 16-731Status Indicator RAPs Prelaunch Training/Review 16-730 ART CommandART IV Command Invalid.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Delete the unsupported command from the data and retry printing. 16-731 TIFF DataInvalid TIFF Data. The TIFF data is broken or cut halfway.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Resend the data, etc.
Page 304
6/02 2-274DC1632/2240 16-735, 16-737 Prelaunch Training/Review Status Indicator RAPs 16-735 Job TemplateThe system tried to output the Job Template List while the Job Template was being updated.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Run the job again after the Job Template update has completed. 16-737 Server ReadRead error from the Job Template Pool ServerProcedureSwitch power off then on. The problem continues. YN Return to service call...
Page 305
6/02 2-275 DC1632/2240 16-739, 16-740Status Indicator RAPs Prelaunch Training/Review 16-739 Job Template PathThe specified path of the Job Template Pool Server cannot be found.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Set the resource of the storage destination path from a client PC on the CentreWare. 16-740 Job Template LoginJob Template Server Login Error. Cannot log in to the Job Template Pool Server.ProcedureSwitch power off then on. The...
Page 306
6/02 2-276DC1632/2240 16-741, 16-742 Prelaunch Training/Review Status Indicator RAPs 16-741 Job Template ConnectionCannot connect to the Job Template Pool Server.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Connect the cable from the M/C to a network correctly. From the destination server, check that you can identify the M/C with ping. Perform the ping test on the destination server from . From a client PC to check that the FTP connection to the...
Page 307
6/02 2-277 DC1632/2240 16-743, 16-744Status Indicator RAPs Prelaunch Training/Review 16-743 Job Template InstallationJob template pool server installation error or job template pool server setting failureProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Set the Spool Server related parameters again. 16-744 Job Template AddressThe Job Template Pool Server address cannot be solved (Response to the DNS library error)ProcedureSwitch power off then on. The...
Page 308
6/02 2-278DC1632/2240 16-745, 16-748 Prelaunch Training/Review Status Indicator RAPs 16-745 Job Template DefinitionThe Job Template Pool Server address cannot be solved (The DNS address is not set)ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Set the DNS address. Or set the Job Template Pool Server address by the IP address. 16-748 HD FullFull status was detected at HD access and a job was aborted.ProcedureSwitch power off then on. The problem...
Page 309
6/02 2-279 DC1632/2240 16-749, 16-757Status Indicator RAPs Prelaunch Training/Review 16-749 XJCL SyntaxSyntax error of the JCL command was detected.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Correct the command. 16-757 Auditron UserInvalid Auditron UserProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Set a correct account and retry.
Page 310
6/02 2-280DC1632/2240 16-758, 16-759 Prelaunch Training/Review Status Indicator RAPs 16-758 Auditron FunctionAn auditron function is disabled.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Consult the account administrator to add a right. Set the new function that is allowed for that account and retry. 16-759 Auditron LimitAuditron reached limit.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Consult the...