Page 271
Toll Restriction2-245 Chapter 2 - Features and Operation 5. When all entries for one table are complete, press the flexible button for the next table. To erase a bin number: 1. Enter a valid bin number. 2. Press the HOLD button. Deny Table Description Each Deny Table contains ten bin numbers. Each bin number may be up to eight-digits including {Do Not Care} digits. Entries in the Deny Table represent numbers or codes that are to be denied or restricted. Common entries would be [1] for restricting all...
Page 272
2-246Toll Restriction Chapter 2 - Features and Operation Special Table Description The Special Tables provide greater flexibility in designing a toll plan for a particular site. Each Special Table allows entry of up to 800 office codes (200–999). Three of these tables must be assigned an area code by which they are referenced. The fourth table is reserved for the home area code and requires no area code entry. The Special Tables are referenced through entries in the allow tables. Four area codes,...
Page 273
Toll Restriction2-247 Chapter 2 - Features and Operation To enter office codes in a special table: 1. Press the SPECIAL TABLE (#1 to #4) flexible button (FLASH 70, Buttons #5 to #8) that corresponds to the area code programmed above. The following message displays: XXX = Area Code 2. Enter the office codes that are to be allowed or removed as follows: XXX [1] = Allow Code XXX [0] = Remove Code from the list (XXX = An office code from 200 to 999) 3. Press HOLD after every code entered. A confirmation...
Page 274
2-248Toll Restriction Chapter 2 - Features and Operation Press the DISPLAY TABLES button again, the next 6 entries display. This continues until all codes are displayed. XXX= Area Code YYY= Allowed Office Code Initialize Exception Tables Description The Exception Tables parameters, including the Allow/Deny Tables and the Special Tables, may be initialized setting all tables to their original, default values. The following Tables are cleared returning to their default value upon initializing the...
Page 275
Toll Restriction2-249 Chapter 2 - Features and Operation Print Exception Tables Description The Print Exception Tables command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. When printing information from the Exception Tables, the following data prints: Allow Table A and Deny Table A A ll o w Ta b l e B a n d D e n y Ta b l e B Special Tables 1, 2, 3, and 4 Figure 2-19:...
Page 276
2-250Toll Restriction Chapter 2 - Features and Operation Programming Steps 1. Press the EXCEPT TABLES flexible button (FLASH 85, Button #5). The following message displays: 2. To print the Except Tables, press the HOLD button. The following message displays: When the system finishes sending the requested information to the printer, a confirmation tone sounds. Toll Restriction Related Items CO/PBX Lines When CO lines are marked as PBX lines the system first checks the PBX code table for a valid match....
Page 277
Uniform Call Distribution2-251 Chapter 2 - Features and Operation Two (2) options are available to help alleviate this problem: 1. Shorten the SLT receiver timer [FLASH 01] [Button 12]. This frees up DTMF receivers faster, but may not provide the desired toll restriction for SLT stations. 2. Enable LCR and force LCR on SLT stations. When the LCR database is set up, the 3-digit table allows entry of the number of digits to expect. When a SLT dials the appropriate number of digits, LCR releases the DTMF...
Page 278
2-252Univer sal Day/Nig ht A ns we r Chapter 2 - Features and Operation Universal Day Answer (UDA) Description UDA-assigned CO lines can signal over external page port(s). External Day ringing is programmed on a system-wide basis in administrative programming. Stations that do not have access to a line during the day can answer that line while the System is in the day mode by dialing a UDA code [#5]. To use this feature, a LOOP button or an appearance of the trunk must be present on the station....
Page 279
Universal Day/Night Answer2-253 Chapter 2 - Features and Operation » If External Day ring is disabled, or the system is not in the day mode, external page ringing is disabled. » Ringing CO lines not assigned CO line group access for a particular SLT may be answered in a UDA service. Dialing privileges are unavailable on CO lines to which an SLT does not have access. CO lines without UDA status may not be answered or accessed via UDA procedures. » If two single-line telephones attempt to retrieve one...
Page 280
2-254Vo i c e Ma i l Chapter 2 - Features and Operation 5. Enter a 0 or 1 on the dial pad to enable/disable this feature. [0] = Disabled [1] = Enabled 6. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT … UNA is enabled. Vo i c e Ma i l Description Up to 8 Voice Mail groups can be configured in the Triad-S system. Each group can contain up to 24 Voice Mail designated ports, each of which interfaces with a port on an SLT card (or DIDB if using a Digital Voice Mail). An externally...