Page 131
Unit Startup RT-SVX24K-EN131 Table 41. Energy recovery wheel component static pressure drops Nom Tons CFM Outside Air Bypass Damper Open Outside Air Bypass Damper Closed Exhaust Air Bypass Damper Open Exhaust Air Bypass Damper Closed Low CFM Energy Recovery Wheel 90/100 8000 0.07 0.78 0.09 0.66 9000 0.09 0.88 0.11 0.79 10000 0.12 0.99 0.14 0.92 12000 0.16 1.20 0.19 1.16 14000 0.21 1.42 0.24 1.41 16000 0.27 - 0.29 - 20000 0.40 - 0.42 - 25000 0.59 - 0.60 - 30000 0.80 - 0.80 - 33000 0.94 - 0.94 - 36000...
Page 132
Unit Startup 132RT-SVX24K-EN Nom Tons CFM Outside Air Bypass Damper Open Outside Air Bypass Damper Closed Exhaust Air Bypass Damper Open Exhaust Air Bypass Damper Closed 130/140 9000 0.09 0.71 0.10 0.62 12000 0.15 0.97 0.18 0.92 16000 0.25 1.34 0.28 1.33 20000 0.36 - 0.40 - 23000 0.46 - 0.49 - 26000 0.57 - 0.60 - 30000 0.72 - 0.75 - 35000 0.93 - 0.97 - 40000 1.16 - 1.20 - 45000 1.40 - 1.43 - 50000 1.67 - 1.69 - 55000 1.95 - 1.96 - 58000 2.12 - 2.12 - 150/162 9000 0.09 0.71 0.10 0.62 12000 0.15 0.97...
Page 133
Unit Startup RT-SVX24K-EN133 Nom Tons CFM Outside Air Bypass Damper Open Outside Air Bypass Damper Closed Exhaust Air Bypass Damper Open Exhaust Air Bypass Damper Closed 105/118 9000 0.08 0.57 0.09 0.47 12000 0.14 0.77 0.16 0.65 14000 0.19 0.93 0.21 0.78 16000 0.24 1.08 0.26 0.91 19000 0.32 1.33 0.34 1.11 21000 0.37 1.49 0.40 1.25 23000 0.44 - 0.46 - 28000 0.61 - 0.64 - 33000 0.80 - 0.82 - 38000 1.00 - 1.03 - 43000 1.23 - 1.25 - 45000 1.33 - 1.34 - 120/128 10000 0.10 0.56 0.11 0.50 12000 0.14 0.69...
Page 134
Unit Startup 134RT-SVX24K-EN Tons CFMReturn Damper, ERW only Econo Damper, ERW only 90/100 16000 0.14 0.15 20000 0.20 0.24 25000 0.29 0.39 30000 0.42 0.56 33000 0.51 0.69 36000 0.61 0.82 40000 0.75 1.01 105/118 19000 0.19 0.22 23000 0.25 0.33 28000 0.37 0.49 33000 0.51 0.69 38000 0.68 0.91 43000 0.87 1.17 45000 0.96 1.29 120/128 21000 0.22 0.18 26000 0.32 0.27 31000 0.45 0.39 36000 0.61 0.53 41000 0.79 0.69 46000 1.00 0.87 51000 1.24 1.07 54000 1.40 1.20 130-162 23000 0.25 0.21 26000 0.32 0.27 30000...
Page 135
Unit Startup RT-SVX24K-EN135 Table 42. Energy recovery wheel pLossP(in. wg), and total effectiveness Actual Air Flow CFM 90-118 Tons Low 120/128 Tons Low 130-162 Tons Low 90/100 Tons Standard 105/118 Tons Standard 120/128 Tons Standard 130-162 Tons StandardP Eff P Eff P Eff P Eff P Eff P Eff P Eff 8000 0.73 77.5 0.64 79.0 0.58 80.0 0.49 81.6 9000 0.82 75.9 0.72 77.6 0.65 78.7 0.55 80.6 0.51 81.3 10000 0.91 74.3 0.80 76.2 0.73 77.5 0.61 79.5 0.56 80.3 0.49 81.6 11000 1.00 72.7 0.88 74.8 0.80...
Page 136
Unit Startup 136RT-SVX24K-EN Pressure Curves (60 Hz) Air-Cooled Condensers Figure 84. Operating pressure curve (all comp. and cond. fans per ckt. on)—90 tons std. capacity Figure 85. Operating pressure curve (all comp. and cond. fans per ckt. on)—90 tons high capacity
Page 137
Unit Startup RT-SVX24K-EN137 Figure 86. Operating pressure curve (all comp. and cond. fans per ckt. on)—105 tons std. capacity Figure 87. Operating pressure curve (all comp. and cond. fans per ckt. on)—105 tons high capacity
Page 138
Unit Startup 138RT-SVX24K-EN Figure 88. Operating pressure curve (all comp. and cond. fans per ckt. on)—120 tons std. capacity Figure 89. Operating pressure curve (all comp. and cond. fans per ckt. on)—120 tons high capacity
Page 139
Unit Startup RT-SVX24K-EN139 Figure 90. Operating Pressure Curve (All Comp. and Cond. Fans per ckt. on)—130 Tons Std. Capacity Figure 91. Operating Pressure Curve (All Comp. and Cond. Fans per ckt. on)—130 Tons High Capacity
Page 140
Unit Startup 140RT-SVX24K-EN Note:Due to the variable speed fans on Evaporative Condenser units, typical operating pressure curves are not relevant. If operating pressures at certain conditions are needed, contact a local Trane sales representative. Figure 92. Operating pressure curve (all comp. and cond. fans per ckt. on)—150 ton std. capacity Figure 93. Operating pressure curve (all comp. and cond. fans per ckt. on)—90 tons standard capacity