Fault Finding Station Cable Continuity Check Strata DK I&M 5/9912-9 Fault Finding Cable Installation Test If cable voltmeter and ohmmeter tests are within limits, digital telephones, DDCBs, or DDSS consoles may not operate. ä To perform the cable installation test 1. Cable runs for the above digital devices must be free of cable splits (single or double). Test for and eliminate all cable splits. 2.Cable bridge taps – Digital telephones will not operate if cable runs contain any type (short or long) of...
Page 502
Fault Finding Fault Isolation Flowcharts 12-10Strata DK I&M 5/99 Fault Isolation Flowcharts The following troubleshooting flowcharts are available to aid in fault isolation. Toshiba recommends reading the previous text in this chapter before proceeding to Flowchart 12-1 on Page 10 to begin fault isolation. START Please read Chapters 2 and 3 before proceeding. Is the system completely non-operational? Is it a station no dial tone fault? Is it a CO line no dial tone fault? Is a DSS console non-...
Page 503
Fault Finding Fault Isolation Flowcharts Strata DK I&M 5/9912-11 Fault Finding Flowchart 12-2 Catastrophic Faults START Is the system completely non-operational? Was the fault isolated by completing the system hardware check? Was the fault cleared after re-initializing the system? Call your technical support group. Does the fault re-occur after entering customer database? Reprogram customer database, one program at a time, and check to see if fault re-occurs.Tag the defective unit(s) and return for...
Page 504
Fault Finding Fault Isolation Flowcharts 12-12Strata DK I&M 5/99 Flowchart 12-3 Station Dial Tone Faults START Repair if necessary. Is the fault cleared?3-1 END Yes Is the faulty station on a replaceable station PCB? 3-2 Replace the PCB and retest 3-3 Replace the DK14 or DK40i Base KSU. Or, test the DK424 common control PCB per the Fault Isolation section. Initialize the DK424/DK40i system (Prog: 91-9 and 03). Are the faulty station(s) only in the DK40i Expansion KSU or only one DK424...
Page 505
Fault Finding Fault Isolation Flowcharts Strata DK I&M 5/9912-13 Fault Finding Flowchart 12-4 CO Line Dial Tone Faults Is the fault cleared? Go to 4-5 Call your technical support group.NoNo Yes Yes Retest. Change the DK14 or DK40i Base KSU or test the DK424 common control PCB per the Fault Isolation section and initialize the system (Prog. 91-9 and 03).Is the fault cleared?Go to 4-5 4-7 No No Are the faulty CO lines only in the DK40i Expansion KSU or one DK424 Cabinet? 4-10 4-5 Is the fault...
Page 506
Fault Finding Fault Isolation Flowcharts 12-14Strata DK I&M 5/99 Flowchart 12-5 DSS Console Faults START DSS console type? 5-0 END DDSS Go to 5-0 Is the correct PCB slot code entered in Program 03?Enter correct PCB slot code using Program 03; then turn power OFF (for 5 seconds) and then ON. 5-3 Refer to Chapter 8 and verify wiring: Is the fault cleared?Yes 5-4 Go to 5-3 HDSS No On PEKU connected to HDSS, set SW1 to the DSS position. 5-1 No 5-2 Is the fault cleared?• •For DDSS, circuit 8 of the base unit...
Page 507
Fault Finding Fault Isolation Flowcharts Strata DK I&M 5/9912-15 Fault Finding Flowchart 12-6 Voice Mail/(External) Auto Attendant Faults Is the fault cleared?Yes END START This chart assumes the VM/AA device has no faults. Is the fault cleared?Yes 6-3 No 6-2 Is VM/AA integration completely non-operational? END Yes Read “Voice Mail Options” in Chapter 10 and the programming instructions for: DK14/DK40i: 03 (Code 92, slot 00 for K4RCU3) DK424: 03 (Code 92~94 for RCTU PCB) DK14/DK40i/DK424: 15-0 and...
Page 508
Fault Finding Fault Isolation Flowcharts 12-16Strata DK I&M 5/99 Flowchart 12-7 Station Message Detail Recording (SMDR) Faults START No SMDR data or garbled data is detected at the QSMU, WSIU/TSIU/PIOU/PIOUS/ RSIU/RSIS SMDR port. 7-1 Is the fault cleared?Yes 7-5 No This chart assumes the SMDR device has no faults. No END Yes Read the SMDR installation instructions in this chapter before proceeding with this chart. SMDR data records are sent correctly but not when the customer requires. 7-2Yes...
Page 509
Fault Finding Fault Isolation Flowcharts Strata DK I&M 5/9912-17 Flowchart 12-8 Remote Maintenance Faults START Is Remote Maintenance connection via external modem on TTY port or IMDU modem?IMDU modem installed on PIOU or PIOUS 8-1 END This chart assumes that the remote terminal and modem have no fault and that Remote Maintenance does not operate. Is the fault cleared? Call your technical support group. If a digital or electronic telephone is in the Programming mode, it is not possible to enter the...