Page 451
Peripheral Installation PC/Data Communications Interface Units Strata DK I&M 5/9910-69 Peripheral Installation ä To connect the PC to the printer äPress DWD&DOO + on the DKT. CONNECT on the PDIU-DS lights. The connection between the PC and the printer is completed, as shown in Figure 10-36. (PDIU-DS 203 is in the communication mode). NoteIf busy tone is sent to the DKT, the connection is not complete; press DWD5HOHDVH and Step 3 again. Operate the PC to print data as required. Figure 10-36...
Page 452
Peripheral Installation PC/Data Communications Interface Units 10-70Strata DK I&M 5/99 NoteWith an RPCI-DI, you may need to switch the RPCI from the TAPI mode to the data communication mode before proceeding with Step 3. 3. To place the RPCI into the data communication mode from the PC keyboard: Set Num Lock ON, and hold the Alt key down while typing 240 (this is HEX F0). If the RPCI is in data communication mode, ATC0 switches back to TAPI mode. 4.From PC 1’s keyboard, type ATDD204 and...
Page 453
Peripheral Installation PC/Data Communications Interface Units Strata DK I&M 5/9910-71 Peripheral Installation Figure 10-37 Internal PC to External PC Test Call Using AT Commands External PC-to-Internal PC Test See Figure 10-38 for additional information. 1. Set the RPCI or DIU programming. ©Program 20: Port 000. LEDs 01, 02, 05, and 17 ON; all other LEDs OFF. ©Program 20: Port 004. LEDs 01, 02, 04, and 17 ON; all other LEDs OFF. ©Program 39: Port 000. DWD&DOO (456) and DWD5HOHDVH (454) buttons...
Page 454
Peripheral Installation PC/Data Communications Interface Units 10-72Strata DK I&M 5/99 NoteIf using an RPCI-DI, it may be necessary to switch the RPCI from the TAPI mode to the Data Communications Mode before proceeding with Step 3. To place the RPCI into the data communications mode from the PC keyboard: Set Num Lock to ON and type 240 while holding the Alt key down (this is HEX F0). If in the data communication mode, ATC0 will switch the RPCI-DI back to the TAPI mode. 3.From PC 2’s keyboard,...
Page 455
Peripheral Installation PC/Data Communications Interface Units Strata DK I&M 5/9910-73 Peripheral Installation Notes lWhen a PDIU-DS is connected with modified RS-232 cable, the READY LED will not light until the External and Internal modem establish carrier detect. lSee “PDIU-DS to Modem Installation”, paragraph three and Figure 10-29 for more details. Figure 10-38 External PC to Internal PC Test Call Using Direct CO Line Connection PC Auto Dial Voice Call Test There are many off-the-shelf, Windows...
Page 456
Peripheral Installation PC/Data Communications Interface Units 10-74Strata DK I&M 5/99 ©Program 39: Port 001. DWD&DOO (556) and DWD5HOHDVH (554) buttons are optional. If the PDIU-DI is only used for the PC auto dial application, the DWD&DOO and DWD 5HOHDVH buttons are unnecessary. 2. Make sure that the auto dial application software is installed on the PC root directory and that the communication parameters of the PC and application software are set to the same values. NoteIf using an...
Page 457
Peripheral Installation DK Alarm Sensor Strata DK I&M 5/9910-75 Peripheral Installation Figure 10-39 DK PC Auto Dial Voice Call Test DK Alarm Sensor The PIOU or PIOUS PCB provides a circuit that can be set to detect a relay open or closed condition from a facility alarm system. When the sensor is activated, all electronic and digital telephones sound an alarm signal. The electronic/digital telephone alarm signal can be reset by any electronic or digital telephone with an $ODUP5HVHW button (see...
Page 458
Peripheral Installation Auto Attendant 10-76Strata DK I&M 5/99 Alarm Sensor Wiring See Figure 10-40, and connect the facility alarm system relay contacts to the PIOU/PIOUS PCB. Figure 10-40 DK Alarm Sensor Block Diagram (PIOU/PIOUS) Auto Attendant Auto Attendant operates like an automatic station attendant or switchboard operator that quickly and efficiently distributes calls to stations selected by callers. Incoming calls are greeted by an external announcement device that offers callers a menu of...
Page 459
Peripheral Installation Auto Attendant Strata DK I&M 5/9910-77 Peripheral Installation Strata DK Built-In Auto Attendant (AA) A built-in Auto Attendant feature is programmed into the Strata DK system software. To enable the built-in AA to function, RRCS (-4, -8 or -12) DTMF tone receiver PCB (see Chapter 8 – DK40i/DK424 Universal Slot PCB Wiring for RRCS and RKYS installation instructions). The customer must provide digital announcement device(s), on which the greeting and menu that the callers...
Page 460
Peripheral Installation Auto Attendant 10-78Strata DK I&M 5/99 Sequence D The call is not answered after being transferred from the Auto Attendant and is routed back to the primary announcement. This is probably the least desirable of the four sequences, since the caller hears a repeat of the announcement he just received seconds earlier. NoteIn all of the above sequences, the call can first ring telephones selected in system programming for 12 or 24 seconds, and then be routed to the Auto...