Page 441
Peripheral Installation PC/Data Communications Interface Units Strata DK I&M 5/9910-59 Peripheral Installation DIP Switch Options The RPCI-DI, PDIU-DI and the PDIU-DS each have a four-control DIP switch which can be configured for signaling options. The switch is located on the bottom of the PDIU-DI, and on the back panel of the PDIU-DS (see Figure 10-33). SW1-1 Normally, this switch is set ON to disconnect devices from RPCIs or DIUs automatically. The connection is maintained if data is exchanged...
Page 442
Peripheral Installation PC/Data Communications Interface Units 10-60Strata DK I&M 5/99 Figure 10-33 RPCI-DI, PDIU-DI, PDIU-DS SW1 DIP Switch Information 1 2 3 4 1234DNTAON OFF 1534 Switch SW1 (1) SW1 (2) SW1 (3) SW1 (4)Function Forced hang up when DIU does not detect space signal on TD or RD for about 8 to 9 minutes On: enable (auto-disconnect) 1 Off: disable DCD, DSR control On: continuous on Off: DSR depends on DTR (DCD is on during communication state) RI control On: RI is on continuously during...
Page 443
Peripheral Installation PC/Data Communications Interface Units Strata DK I&M 5/9910-61 Peripheral Installation RPCI-DI and PDIU-DI to PC Installation The RPCI-DI and PDIU-DI always functions as a DCE device; it transmits data on the Receive Data lead (RD) and receives data on the Transmit Data lead (TD). Most personal computers function as a DTE device; PCs transmit data on the TD lead and receive data on the RD lead. NoteThe RPCI-DI or PDIU-DI can connect to a DCE computer or any other DCE-type...
Page 444
Peripheral Installation PC/Data Communications Interface Units 10-62Strata DK I&M 5/99 ©LED 05: Should be ON if the system is installed behind a PBX or Centrex that uses access codes to make external calls or to insert a pause following RPCI DIU access of an outside line. ©LED 10: Enables Caller ID and ANI information to be sent from RCPI-DI to the connected PC. ©LED 11: Enables DNIS information to be sent from the RCPI-DI to the connected PC. ©LEDs 17~20: Used to establish data security groups....
Page 445
Peripheral Installation PC/Data Communications Interface Units Strata DK I&M 5/9910-63 Peripheral Installation Important!Check the printer’s serial documentation for correct RS-232 pin requirements. The requirements vary with each manufacturer. PDIU-DS Programming ©Program 20: Configures the PDIU-DS to connect to a serial printer (see Strata DK Programming Manual for instructions and record sheets). ©LED 01: Should always be ON for PDIU-DS ports. ©LED 02: Should be OFF for PDIU-DS ports connected to...
Page 446
Peripheral Installation PC/Data Communications Interface Units 10-64Strata DK I&M 5/99 ä To configure the PDIU-DS as a DTE device 1.Disassemble the PDIU-DS and place jumper plugs P1~P9 in the “B-C” position (MODEM). 2. Reassemble the PDIU-DS and mark “B-C” on the bottom identification label for future reference. (See Figures 10-32 and 10-33.) ä To install modems to PDIU-DSs 1. Connect the PDIU-DS to the appropriate digital port circuit per the wiring diagrams in Chapter 8 – DK40i/DK424 Universal...
Page 447
Peripheral Installation PC/Data Communications Interface Units Strata DK I&M 5/9910-65 Peripheral Installation ©Program 21: For each PDIU-DS/modem pair, assign the digital, RSTU2, RDSU/RSTS, and PESU ports that will be connected to the PDIU-DS and modem, respectively. ©Program 22/33: If more than one modem/PDIU-DS pair is configured as a system modem pool, the PDIU-DSs should be set to hunt each other in Program 22. The modem RSTU, PSTU, RDSU/RSTS, or PESU ports should be set to hunt each other in...
Page 448
Peripheral Installation PC/Data Communications Interface Units 10-66Strata DK I&M 5/99 Notes lDo not cut the Perception jumper wire for Strata DK installation. lJumper wire is for Perception applications only. Figure 10-34 DK PDIU-DS Disassembly/Assembly Diagram RPCI-DI/PDIU-DI/PDIU-DS Data Communication Installation Tests The following material provides tests for five RCPI/DIU data call applications: ©PC-to-PC ©PC-to-Printer ©Internal PC-to-External PC ©External PC-to-Internal PC ©PC Auto Dial Voice...
Page 449
Peripheral Installation PC/Data Communications Interface Units Strata DK I&M 5/9910-67 Peripheral Installation Each of these tests can be conducted with manual dialing from a digital telephone’s dial pad or AT dialing from a personal computer’s keyboard; however, only the preferred method of dialing for application is presented. PC-to-PC Test with AT Commands NoteSee Figure 10-35, “DK PC to PC Test Call Using AT Commands” for additional information. 1. Set RPCI or DIU programming. ©Program 20:...
Page 450
Peripheral Installation PC/Data Communications Interface Units 10-68Strata DK I&M 5/99 Figure 10-35 DK PC to PC Test Call Using AT Commands PC-to-Printer Test using Manual Dialing NoteSee Figure 10-36 for additional information. 1. Set the RPCI or DIU programming. ©Program 20: Port 001. LEDs 01, 02, 05, and 17 ON; all other LEDs OFF. ©Program 20: Port 003. LEDs 01, 04, and 17 ON; all other LEDs OFF. ©Program 39: Port 001. DWD&DOO (456) and DWD5HOHDVH (454) buttons should be provided. ©Default...