Page 481
DK424 ACD Installation ACD Line Operation/Programming Considerations Strata DK I&M 5/9911 - 13 DK424 ACD Installation 018D 018ACD 44034414 50001:32 01:3200:00;13 00:00;1700;14 4403 *7145833700** 018D 4403 500 02:05 00:00;06 00;19 *7145833700** 019D 4403 500 02:47 00:00;04 00;18 *7145833777*2222* DR JONES Direct ACD call with ANI/Caller ID Number, answered by ACD Queue Announcer 4414. Call stays in queue until Agent button, [PhDN] 500 on Station 4403 becomes available. Agent answers...
Page 482
DK424 ACD Installation Insight DK (DK424 only) 11- 14Strata DK I&M 5/99 Figure 11-10 Delay Ring to Built-in AA Example Insight DK (DK424 only) The Insight DK™ and Insight DK Plus are full-featured ACD MIS tools for call center supervisors, providing user-defined supervisor displays, user-defined historical reports, electronic wall board connections, and inView LAN-based status display messaging. Insight DK and DK Plus are Windows-based MIS software programs that work with PCs running Microsoft ®...
Page 483
DK424 ACD Installation Call Center Viewer (CCV) Strata DK I&M 5/9911 - 15 DK424 ACD Installation ©Longest Call Waiting ©Strata DK Date/Time ©Wall Board Messages Strata DK Requirements The RKYS3 must be installed on the Strata DK RCTU processor card in order for the Call Center Viewer to work. Host PC Requirements The host PC does not have to be dedicated to the application, since the Call Center Viewer application was designed for multi-tasking. When the Call Center Viewer application connects to the...
Page 484
DK424 ACD Installation CCV Configuration 11- 16Strata DK I&M 5/99 Following is an example of a typical Call Center Viewer display. Reference Information Refer to the Call Center Viewer User Guide for software installation and operation instructions. CCV Configuration Considerations The Call Center Viewer application can connect solely to the Strata DK280 or DK424 port, or in parallel with other CCV applications, or with a Software MIS (SMIS) computer. The number of CCV PCs and the hardware...
Page 485
DK424 ACD Installation CCV Configuration Strata DK I&M 5/9911 - 17 DK424 ACD Installation PPTC Connector A PPTC-9 or PPTC-25F is used to connect a six conductor standard telephone cord plug to connect the PC’s COM port (see Figure 11-12). There are three models of the PPTC appropriate for this application. See Figure 11-13 for pinout details for connecting the Call Center Viewer with equipment, such as Line Drivers and Data Broadcast Units. Line Driver An RS-232 short-haul modem or Line Driver...
Page 486
DK424 ACD Installation CCV Configuration Instructions 11- 18Strata DK I&M 5/99 Line Drivers must be used in pairs. Figure 11-15 shows the connections between the two line drivers. Figure 11-15 Twisted Pair Connections Instructions for connecting PCs more than 50 feet from the Strata DK are covered later in this section. Data Broadcast Unit The Data Broadcast Unit (Figure 11-16) enables you to connect more than three PCs to with the Call Center Viewer application. A data broadcast unit regenerates...
Page 487
DK424 ACD Installation CCV Configuration Instructions Strata DK I&M 5/9911 - 19 DK424 ACD Installation Connecting the DK to a Stand-alone CCV PC, More than 50 Feet Away 1. Connect the Strata DK280 or DK424 MIS port (RSIU/RSIS, RSSU, PIOU, or PIOUS PCB) to the ME764-MSP Line Driver with an RS-232 cable (see Figure 11-18). Set the switch on the Line Driver to DTE. 2. Connect the other end of the Line Driver to the COM port of the host PC. Set the switch on this Line Driver to DCE Figure 11-18 Connecting...
Page 488
DK424 ACD Installation CCV Configuration Instructions 11- 20Strata DK I&M 5/99 Connecting CCV and SMIS Call Center Viewer monitors the data flowing between the Toshiba SMIS and the Strata DK. This enables the CCV application PC to display information and work in conjunction with a SMIS computer that is connected to the same Strata DK280 or DK424 MIS port. The CCV application and the SMIS application must reside on separate computers because SMIS requires a dedicated PC. The CCV provides the real-time...
Page 489
DK424 ACD Installation CCV Configuration Instructions Strata DK I&M 5/9911 - 21 DK424 ACD Installation Connecting Up to Three CCV PCs If you are connecting multiple PCs with the CCV application, use: One Call Center Viewer “Y” Connector (CCVY) One six-conductor telephone cord per PC, plus one cord for the DK to CCVY connection One PPTC-9 or PPTC-25F pin connector per PC äTo connect up to three CCV PCs to the Strata DK 1. Install the CCVY connector into the Strata DK MIS port (RSIU, RSIS, RMDS, or PIOU...
Page 490
DK424 ACD Installation CCV Configuration Instructions 11- 22Strata DK I&M 5/99 Connecting the CCV to More than Three CCV PC Use a Data Distribution Box when you are connecting more than three PCs using the CCV software. You will also need the connectors listed on the previous page. äTo connect Strata DK to multiple CCV PCs 1. Install the CCVY connector into the Strata DK MIS port (RSIU, RSIS, RMDS, or PIOU PCBs). See Figure 11-21. 2.Use a six-conductor twisted pair telephone cord to connect the DK MIS...