Page 531
ISDN Interfaces RPTU Interface Unit Strata DK I&M 5/9914-5 ISDN Interfaces Table 14-3 DK424 Base Cabinet with RCTUE3/F4 with MBJU Removed RPTU Installation Before installing a RPTU PCB into a DK424, a number of system programs should be run. This enables the RPTU to function immediately upon insertion. It is recommended that you run these programs in the order listed in the DK Programming Manual (refer to the ISDN section) before beginning installation. ä To install an RPTU PCB 1. Set the jumper...
Page 532
ISDN Interfaces RPTU Interface Unit 14-6Strata DK I&M 5/99 Figure 14-2 RPTU PCB Table 14-4 RPTU Switches, Jumpers, and Connectors Switches/Jumpers/ConnectorDescription SW1 (Line length adjustment switch) Matches the RPTU impedance to the impedance of the line (length between the CSU and the RPTU). Refer to Table 14-6 on Page 14-8. SW2 (Reset switch) 1 1. If this switch on the Primary Clock source RPTU is pressed (Program *42-1), the clock source will automatically revert to the Secondary Clock source...
Page 533
ISDN Interfaces RPTU Interface Unit Strata DK I&M 5/9914-7 ISDN Interfaces Figure 14-3 RPTU LEDs and Connectors Table 14-5 LED Functions LEDFunctions FSYCFrame Synchronization ON: Frame alignment is lost. OFF: Frame alignment is working properly. AISAlarm Indication Signal ON: Receiving an alarm from the CO. OFF: Circuit is working properly. RABRemote Alarm ON: Receiving a remote alarm from the CO. OFF: Circuit is working properly. LOSLoss of Signal ON: IC signal cannot be detected. OFF: Circuit is...
Page 534
ISDN Interfaces RPTU Interface Unit 14-8Strata DK I&M 5/99 Cabling To meet Part 15 of FCC Rules, ISDN PRI equipment must be connected using CAT5, Shielded Twisted-Pair (STP) cabling between the CSU and the RPTU. CAT5 STP protects against cross talk, Radio Frequency Interference (RFI), and/or Electro Magnetic Interference (EMI). STP protects ISDN signal data while being transmitted through the cable and keeps the cable itself from emitting EMI and RFI. Important!To avoid ground loops, connect only the...
Page 535
ISDN Interfaces RPTU Interface Unit Strata DK I&M 5/9914-9 ISDN Interfaces Cable Installation The RPTU PCB is shipped with a Toshiba RPRI cable kit for connection of the RPTU to a CSU. Install the kit as shown in Figure 14-3. Figure 14-4 Detailed Pinouts for ISDN PRI Cabling Network Jack/RPTU Modular Jack PinFunction 1Tip – Receives from the network (NT – TE) 2 Ring – Receives from the network (NT – TE) 3 Not Used 4 Ring – Transmits to the network (TE – NT) 5 Tip – Transmits to the network (TE –...
Page 536
ISDN Interfaces RPTU Interface Unit 14-10Strata DK I&M 5/99 Ferrite Core Install the Ferrite core provided with the RPRI cable kit as shown in Figure 14-5. This core is needed to comply with FCC requirements. Figure 14-5 Ferrite Core Installation RPTU Testing and Troubleshooting Loop-back Testing The RPTU has loop-back test jumpers that enable physical connections (cables/jacks/plugs) between the RPTU, CSU, and the network PRI line to be tested (see Figure 14-6). The tests check that the CSU receives...
Page 537
ISDN Interfaces Timing and Synchronization Strata DK I&M 5/9914-11 ISDN Interfaces 3. Turn the DK power ON and connect the PRI modular cord to RPTU RJ-45. 4. After the PRI line and RPTU are synchronized, have the CO generate the loop-back test sign (all “1s” or “0s”). CAUTION!Do not have the CO do a QRS loop-back test, because the test signal may cause the DK to drop all calls and/or stop operating. 5. If the loop-back test fails, perform tests to isolate the problem with an ISDN test set, such as...
Page 538
ISDN Interfaces Timing and Synchronization 14-12Strata DK I&M 5/99 The RCTU time switch is synchronized as the slave to the PRI, BRI, or T1 line (Line 1 in Figure 14-7). The DK424 PRI, BRI, or T1 in any slot number can be assigned as the Primary reference (Program *42-1, DATA=1 for this PRI, BRI, or T1). If a malfunction occurs and Primary reference synchronization is lost, the DK424 automatically switches modes and synchronizes to the Secondary reference, provided that there is another PRI, BRI, or...
Page 539
ISDN Interfaces RPTU Call Monitoring (PRI) Strata DK I&M 5/9914-13 ISDN Interfaces The Secondary reference is activated if the Primary reference fails. The DK424 automatically switches over to the Secondary reference PCB by opening its synchronization circuit (SS 1) and closing the synchronization circuit (SS 2). When this occurs, the digital voice or data path of the DK424 is synchronized to the Line 2 clock source. If the path is not synchronized to the Stratum – 1 clock source, calls connected...
Page 540
ISDN Interfaces RPTU Call Monitoring (PRI) 14-14Strata DK I&M 5/99 Figure 14-9 Start-up and Synchronization Sequences /*-------------------------*/ Copyright(C) 1997 TOSHIBA Corporation All rights reserved RPTU Ver.1G [Reset] /*-------------------------*/ 00;00 016 Act. (F1) /*-------------------------*/ Copyright(C) 1997 TOSHIBA Corporation All rights reserved RPTU Ver.1G [Reset] /*-------------------------*/ 00;00 016 Act. (F1) 00;09 634 LOS (F3) 00;12 109 Act....