Page 541
ISDN Interfaces RPTU Call Monitoring (PRI) Strata DK I&M 5/9914-15 ISDN Interfaces Figure 14-10 Outgoing Call Connect and Release 01;14’446 Rx:[SAPI]00 C [TEI]000 [FRAME]RR P [N(R)]004 01;14’449 Tx :[SAPI]00 C [TEI]000 [FRAME]RR P [N(R)]002 01;14’456 Tx :[SAPI]00 R [TEI]000 [FRAME]RR F [N(R)]002 01;14’460 Rx:[SAPI]00 R [TEI]000 [FRAME]RR F [N(R)]004 01;19’450 Tx :[SAPI]00 C [TEI]000 [FRAME]INFO [N(S)]004 [N(R)]002 PD = Q.931(08) CR = 02 0003...
Page 542
ISDN Interfaces RPTU Call Monitoring (PRI) 14-16Strata DK I&M 5/99 Performance Monitoring The performance of the RPTU can be monitored using the Data Dump Mode. This requires: ©RSIU, RSIS, PIOU or PIOUS PCB TTY port. ©ASCII terminal or PC with communications software (such as ProComm). ©IMDU or RMDS modem or Hayes compatible modem for remote monitoring. The RPTU monitoring feature provides a download of PRI errors detected as shown in Figure 14-11. This data can be stored to a file and/or printed when...
Page 543
ISDN Interfaces RPTU Call Monitoring (PRI) Strata DK I&M 5/9914-17 ISDN Interfaces Figure 14-11 RPTU Performance Monitor PrintoutPRI ERROR DISPLAY PRIERR PRI NO = 1 SYNCHRO BIT ERROR = XX TIMES (1 TIME = 1024 ERRORS) BIPOLAR VIOLATION ERROR = XX TIMES (1 TIME = 256 X 256 ERRORS) SLIP ERROR = XX TIMES (1 TIME = 256 ERRORS) CRC ERROR = XX TIMES (1 TIME = 256 ERRORS) PRI NO = 2 SYNCHRO BIT ERROR = XX TIMES (XX = 00~15) BIPOLAR VIOLATION ERROR = XX TIMES SLIP ERROR = XX TIMES CRC ERROR = XX TIMES PRI NO = 3...
Page 544
ISDN Interfaces SMDR Output for ISDN 14-18Strata DK I&M 5/99 SMDR Output for ISDN See Figure 10-20 on Page 10-36 for a sample SMDR printout and descriptions of each column. RBSU/RBSS and TBSU Interface Units System:DK424 and DK40i, Release 4.1 and above Circuits per PCB:2 circuits (2B + D each circuit) Interfaces with:ISDN BRI S/T when connected to the Public Network or a BRI S-type, TE-1, or TA devices when connecting to ISDN station equipment Older Version(s):none The Strata DK424 and DK40i Release...
Page 545
ISDN Interfaces RBSU/RBSS and TBSU Interface Units Strata DK I&M 5/9914-19 ISDN Interfaces ©As BRI – NT circuits which connect to ISDN TEs or TAs. These devices must be S-type station devices. Important!The DK424 and DK40i BRI circuits allocate line numbers and station ports differently. In DK424, each BRI circuit consumes two line numbers and two station port when configured as line-side or station side. In DK40i, each BRI line circuit consumes two line numbers and no station ports; each BRI station...
Page 546
ISDN Interfaces RBSU/RBSS and TBSU Interface Units 14-20Strata DK I&M 5/99 be installed in any combination so long as the number of RBSU PCBs is the same or greater than the number of RBSS PCBs. See Ta b l e 1 4 - 7 for the maximum RBSU/RBSS circuits allowed. On DK40i, TBSU and each RBSU and/or RBSS contains two circuits. Each circuit reduces the system capacity by two station ports or two CO lines. If the BRI circuit is configured as NT, the circuit assumes two station ports. If the BRI circuit is...
Page 547
ISDN Interfaces RBSU/RBSS and TBSU Interface Units Strata DK I&M 5/9914-21 ISDN Interfaces TBSU and RBSU/RBSS Installation Step 1: Run Related Programs ä Run all ISDN programs related to TBSU and RBSU/RBSS BRI circuits prior to installation of the PCBs. This enables the circuits to operate immediately upon insertion. ISDN BRI programs are explained in the Strata DK424 Programming Manual under the ISDN tab. Important!For the DK40i, make sure to run Program *60 to identify all station (NT) and CO (TE)...
Page 548
ISDN Interfaces RBSU/RBSS and TBSU Interface Units 14-22Strata DK I&M 5/99 Table 14-8 RBSU/RBSS Option Switches, Jumpers, and Connectors Step 3: Install the REBS NoteThe REBS provides a basic part of the RBSU/RBSS circuit functionality; therefore, it must always be installed on the RBSU (see Figure 14-16). 1.Align the two connectors carefully while observing the “UP” arrows on the REBS. 2. Plug the REBS onto the RBSU. Step 4: Install the RBSS NoteIf one or two additional BRI-NT circuits are required,...
Page 549
ISDN Interfaces RBSU/RBSS and TBSU Interface Units Strata DK I&M 5/9914-23 ISDN Interfaces Figure 14-16 Location of RBSU Plug-on PCBs Step 6: Install RBSU/RBSS PCBs into Cabinet After setting the switches and jumpers and installing the plug-on PCBs as described in the preceding paragraphs, the RBSU/RBSS PCBs can be installed in the appropriate cabinet slots. Refer to RBSU/RBSS Capacity and Cabinet Slot Information on Figure 14-18. After the RBSU/ RBSS is installed in the DK424 cabinet or DK40i...
Page 550
ISDN Interfaces RBSU/RBSS and TBSU Interface Units 14-24Strata DK I&M 5/99 Step 7: Install the TBSU Carefully align the TBSU connector pins with P11 and P12 on the DK40i motherboard and install the TBSU into the DK40i Base Unit. Use the two supplied screws to secure the TBSU to the motherboard. Figure 14-17 shows the TBSU mounting on the DK40i and Figure 14-18 shows the TBSU switch layout. Table 14-10 shows the TBSU option switches. Figure 14-17 Installation of TBSU into DK40i + - TCOU1A V1 TC1U2A...