Page 491
DK424 ACD Installation CCV Configuration Instructions Strata DK I&M 5/9911 - 23 DK424 ACD Installation Figure 11-22Connecting Multiple CCV PCs (More than 50’ from Strata DK) 2232 CCVY Strata DK SMIS Master CCV PC CCV Slave PC1 CCV Slave PC2 CCV Slave PC3 CCV Slave PC4 Second LD can be up to four miles from DK Data Distribution BoxLine Driver Modem Must be less than 50 from DK Line Driver Modem ME764-MSP ME764-MSP PPTC-9 or PPTC-25F connector PPTC-25F connector 6-conductor, twisted pair phone...
Page 492
DK424 ACD Installation Spectrum Electronic Wall Boards 11- 24Strata DK I&M 5/99 Spectrum Electronic Wall Boards Electronic Wall Boards can be connected to each supervisor’s PC to display call center status data over head from the Call Center Viewer application. This provides visibility of important call center event information to both supervisors and agents. The supervisor can also send custom, user defined, text information to the electronic Wall Board. This can be used for general information,...
Page 493
Strata DK I&M 5/9912-1 Fault Finding Fault Finding12 This chapter describes the procedures to diagnose faults in the Strata DK14 and DK40i Key Service Unit (KSU) and the DK424 system. Faults are classified and then cleared by replacing the malfunctioning unit and by performing operational tests in the sequences by prescribed by the fault clearing flowcharts in “Fault Isolation Flowcharts” on Page 12-10. Fault Classification A Fault Classification Flowchart is provided to ensure that fault clearing is...
Page 494
Fault Finding Parts Return 12-2Strata DK I&M 5/99 Faults in the Strata DK40i and DK424 are cleared by replacing PCBs, telephones (digital or electronic) or the power supply, as instructed in the flowcharts. Five symbols are used in the flowcharts, which are identified in Figure 12-1. The flowcharts are sequentially arranged to permit rapid fault localization within the system. All fault clearing must begin with the Fault Classification Flowchart, which is arranged in the correct fault locating...
Page 495
Fault Finding KSU/RCTU Fault Isolation Strata DK I&M 5/9912-3 Fault Finding KSU/RCTU Fault Isolation The DK14 and DK40i KSU circuits, and DK424 RCTU circuits may contain a “soft” fault due to an extremely high level of static electricity and/or improper or no System Initialization. If the KSU or RCTU is found defective during the fault finding procedures, attempt to clear a “soft” fault before returning the DK14 or DK40i KSU, or the DK424 RCTU PCB for repair. ä To clear a “soft” fault 1. Initialize the...
Page 496
Fault Finding DK424 RPSU280 Power Supply Test 12-4Strata DK I&M 5/99 DK424 RPSU280 Power Supply Test This test applies to the base and expansion cabinet RPSU280 and RPSU424 power supplies. Cabinet PCBs may or may not be installed when beginning this test. Some steps in the test require an AC/DC voltmeter that can measure up to 50VDC and 150VAC. Notes lRPSU280 and RPSU424 power supplies are fit, form, and functionally the same. They can be interchanged and mixed in DK280 and DK424 systems. lTo test...
Page 497
Fault Finding DK424 RPSU280 Power Supply Test Strata DK I&M 5/9912-5 Fault Finding Make sure that +5V, –5V, and –24V are within the range specified in Figure 12-2. Do this test with PCBs inserted; if a voltage(s) is not within specification, remove PCBs, one at a time and recheck the voltage. (Power may have to be turned OFF and ON to restore a voltage.) Replace any PCB which causes a voltage fault. If voltage tests out of specification with all PCBs removed from the cabinet, go to Step 7. 7. Unplug...
Page 498
Fault Finding DK424 RPSU280 Power Supply Test 12-6Strata DK I&M 5/99 Figure 12-2 RPSU280 Power Supply Voltage Test Points / Circuit Breakers / Jumper Plugs R11 PCTU S11 S12 S13 S14 S15 S16 R11 S11RCTU S12 S13 S14 S15 S161 2 3 -24V POWER +5V -5V AC INFGDC OUT + BATT- ON OFF DKSUE DKSUB 4252 DC Out Cable/connector FG Wire and Spade Lug 24VDC Circuit Breaker Assignments: Base Jumper Plug AC Power Cord ON/OFF Switch DC VOLTAGE PINS Power Indicator LEDs (Green) –24VDC Circuit Breakers Third Wire Ground or...
Page 499
Fault Finding Station Cable Continuity Check Strata DK I&M 5/9912-7 Fault Finding Station Cable Continuity Check Voltmeter Test Use a voltmeter to check cable continuity between the DK40i KSU/DK424 cabinet, digital or electronic telephone, DSS console, and the attendant console (DK424). Make tests at the modular block. Refer to Ta b l e s 1 2 - 1 and 12-2. ä To perform the voltmeter test 1. Refer to Chapter 8 – DK40i/DK424 Universal Slot PCB Wiring for appropriate MDF wiring diagrams in Chapters 1...
Page 500
Fault Finding Station Cable Continuity Check 12-8Strata DK I&M 5/99 Ohmmeter Test Check the continuity of the cable run between the KSU/cabinet and digital or electronic telephone with an ohmmeter. ä To perform the ohmmeter test 1. Disconnect the DSS console, electronic or digital telephone. 2. At the MDF, remove the bridging clips. 3. At the MDF, place shorting jumper wires between the T and R of pair #1 (green-red), the T and R of pair #2 (black-yellow) and the T and R of OCA pair #3 (blue-white),...