Peripheral Installation Music-on-Hold (MOH)/ Background Music (BGM) Options Strata DK I&M 5/9910-9 Peripheral Installation ä To install the MOH/BGM as BGM 1. Ensure that the MOH option is installed in accordance with “To install the MOH option” on Page 10-4 (see Figure 10-2). 2. The output of the RCTU page/BGM control is applied through the backplane to the output select switch (SW4) on the PIOU or PEPU. Set the SW4 switch to either SPO or SPI, as required: ©SPO – Directs external page and...
Page 392
Peripheral Installation Relay Control Options and Door Lock Control 10-10Strata DK I&M 5/99 5.Using the BGM source’s volume control, adjust the BGM volume to the desired level while listening to BGM via a telephone speaker and/or the external page speakers. When BGM is sent to external speakers via a PIOU or PIOUS or PEPU PCB, use the external amplifier volume control to balance the BGM and page volume levels. External BGM Installation The external BGM options are closely associated with the...
Page 393
Peripheral Installation Relay Control Options and Door Lock Control Strata DK I&M 5/9910-11 Peripheral Installation Configure PIOU, PIOUS or PEPU for External Page Mute Option 1. Set Program 77-1 LED 07 to OFF to configure the PIOU, PIOUS, or PEPU PCB for the external page function. 2. If using a PIOU or PEPU, set the jumper plug P10 on the PIOU or PEPU jumper plug to the MAKE or BREAK position as required: ©MAKE – Shorts the normally open contacts (pins 7 and 32) when external page is activated....
Page 394
Peripheral Installation Relay Control Options and Door Lock Control 10-12Strata DK I&M 5/99 Figure 10-8 PIOUS Relay Control Functional Wiring Diagram Normal Close Normal Open ALM.T ALM.RNH.R NH.T DE.R DE.T SP.R SP.T Break W1 Make K1 W2 K2 W3 PIOUS ALMNHDE 600 TBI Night Bell Break MakeMute Control KSU Backplane MDF 1508 Notes • All wiring connections must be 24 AWG twisted pairs. • Dotted lines and solid lines differentiate optional connections where applicable; do not connect both options...
Page 395
Peripheral Installation Relay Control Options and Door Lock Control Strata DK I&M 5/9910-13 Peripheral Installation Lock Control Function NoteOnly one door lock control is available using an optional PCB (PIOU, PIOUS, or PEPU) and only the optional PCB with the lowest Program 03 Code (41, 42, or 43) will provide the door lock function. 1. Set Program 77-1 LED 07 to ON to configure the PIOU, PIOUS, or PEPU PCB for the door lock control function (see Figure 10-9). 2. Set Program 77-1 LED 20 to OFF...
Page 396
Peripheral Installation Relay Control Options and Door Lock Control 10-14Strata DK I&M 5/99 Door Lock Control with DDCB and HDCB In addition to the option interface PCB (PIOU, PIOUS, PEPU), each DDCB and HDCB can provide one door lock control. ©DK14 provides two door lock controls on DDCB only. ©DK40i provides three door lock controls. The DK424 support DDCBs and HDCBs. ©DK424 RCTUA provides four door lock controls. RCTUB, RCTUBA/BB, RCTUC/D, or RCTUE/F provide five DDCB/HDCB door lock controls....
Page 397
Peripheral Installation Relay Control Options and Door Lock Control Strata DK I&M 5/9910-15 Peripheral Installation 9. Check each telephone door lock button from each station: the DDCB modular B-jack (pins 3 and 4) will momentarily open or close (three or six seconds) when the button is pressed. HDCB Installation (DK40i and DK424 only) 1. Cut jumper W9 of the particular PEKU or PESU that will connect to the HDCB. (See Figure 10-10 and Chapter 8 – DK40i/DK424 Universal Slot PCB Wiring.) 2. Connect...
Page 398
Peripheral Installation Relay Control Options and Door Lock Control 10-16Strata DK I&M 5/99 Figure 10-10 Multiple Door Lock Control Options (DDCB/HDCB) Night Transfer/Night Relay Options with PIOU, PIOUS, or PEPU Night Transfer/Night Relay option may be programmed for either the Night Relay or the MOH relay function. (See Figures 10-7 and 10-8.) NoteOnly the PIOU/PIOUS, or PEPU with the lowest Program 03 code (41, 42 or 43) will provide the Night Transfer (NT) or MOH relay control function. When...
Page 399
Peripheral Installation Relay Control Options and Door Lock Control Strata DK I&M 5/9910-17 Peripheral Installation Configure PIOU, PIOUS or PEPU for Night Transfer 1. In Program 77-1, set LED 05 to OFF to configure the Night/Hold Relay for the Night Transfer function (see Figures 10-7 and 10-8). 2. In Program 77-1, set LED 06 to provide continuous or pulsating relay activation: ©OFF – Programs the relay for continuous activation when the 1LJKW7UDQVIHU button (only) is set in the Night mode. ©ON –...
Page 400
Peripheral Installation Relay Control Options and Door Lock Control 10-18Strata DK I&M 5/99 Configure PIOU, PIOUS, or PEPU for MOH Relay Control 1. In Program 77-1, set LED 05 to ON to configure the Night/MOH relay for the MOH relay function (see Figures 10-8 and 10-9). 2. If using a PIOU or PEPU, set the P11 jumper plug on the PIOU or PEPU to the MAKE or BREAK position, as required: ©MAKE – Shorts the normally open contacts (pins 9 and 34) when any CO line is on hold. ©BREAK – Opens the normally...